Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent SMU (Source Measure Unit) for ICs and Electronic Components 5990-9870EN c20130528 [2]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
SMU (Source Measure Unit) for ICs and Electronic Components 5990-9870EN c20130528 [2]


>> Download SMU (Source Measure Unit) for ICs and Electronic Components 5990-9870EN c20130528 [2] documenatation <<

Text preview - extract from the document
                                                  SMU (Source/Measure Unit) for IC and Electronic Components
                                                  Quick Bench-top Evaluation Series Introduction
                                                  The Agilent B2900A Series of Precision
                                                  Source/Measure Units improves bench-top
                                                  DC measurement efficiency for IC and
                                                  electronic component evaluation.
                                                                                                                                  B2912A (front view)             B2912A (rear view)


                                                Known issues for bench-top IC and electronic component evaluation
With limited bench-top space you cannot afford to accommodate                                 Many benchtop solutions require a PC to display data graphically
multiple single-function instruments.                                                         and make interactive measurements.
 It is difficult to place multiple DC sources, multimeters, etc. on your limited bench-top     Requiring a PC to make interactive measurements is inconvenient and reduces
 space.                                                                                        productivity due to time spent on PC interface issues.
 Changing wiring for each measurement is messy, time consuming and can easily lead to          Adding a PC to your instrument setup takes up valuable bench space.
 improper connections.

IN
     Solution: The B2900A series' architecture reduces the                                    Set SMU's for DUT   Measurement
                                                                                                Solution: The B2900A series' graphical user interface supports
               number of instruments and eliminates messy wiring.                                         real-time IV curve monitoring directly on the instrument.

                                                                              Channel 2 on
         Multimeter         DC Voltage Source                                 the back side

                                                                                                                                                       Dump to           Organize your
                                                                                                   Set SMUs for DUT          Measurement
         Multimeter         DC Voltage Source                                                                                                        USB memory           quick report
                                                                                                                                                                              Quick
                                                                                                                                                                            Evaluation
                                                                                                                                                                              Report
                                                                         Channel 1
                                           RL

        IN            DUT     OUT                            IN         DUT       OUT



                                                                                                         The B2900A series does not require you to lug a PC to the bench. You
             Bench-top setup example                          B2900A setup example                       can monitor graphical measurement results on the B2900A and save
                for 4-terminal DUT                              for 4-terminal DUT                      the graphs to a USB memory stick in both CSV and JPEG formats. This
                                                                                                          improves the efficiency of your bench-top evaluation and debugging.
What is a "Source/Measure Unit"?                                                          What does the graphical user interface offer?
- A Source/Measure Unit (SMU) can perform many roles, thereby                             - The B2900A series can display XY graphs (such as current vs. voltage and
  eliminating multiple rack and stack instruments that require frequent                     time-varying signals ) without requiring a PC.
  cable reconfiguration.                                                                   You can check device characteristics in real time on a
 An SMU integrates the following capabilities into each channel.                           color graphical display during measurement. This
  



◦ Jabse Service Manual Search 2025 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo