Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent Solutions for Millimeter Wave Wireless Backhaul - Application Note 5991-3788EN c20140612 [6]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Solutions for Millimeter Wave Wireless Backhaul - Application Note 5991-3788EN c20140612 [6]


>> Download Solutions for Millimeter Wave Wireless Backhaul - Application Note 5991-3788EN c20140612 [6] documenatation <<

Text preview - extract from the document
Keysight Technologies
Solutions for Millimeter
Wave Wireless Backhaul



                              Designing and Testing E-Band Backhaul
                              Using Effective Network Analysis, and
                              Signal Generation and Analysis Solutions




                Application Note
Overview

    The backhaul plays a critical role in the telecommunications network, comprising
    the intermediate links between the core, or backbone network, and the small subnet-
    works at the edge of the entire network. In microwave mobile or wireless networks,
    there are three types of backhauls: macrocell, small cell and femtocell. Femtocell
    backhauls normally use a broadband access technology and are not covered in this
    application note. Small cell backhauls transport traffic between the outdoor small
    cell site and either the node connecting to a macrocell backhaul network, or the node
    connecting to the Wide Area Network (WAN)/Internet/metro network. It comprises
    equipment at both ends, along with any mesh or serial equipment in between.

    Today, operators have a number of different backhaul technologies to choose from,
    one of which is called E-band. It presents a particularly enviable option due to its
    high capacity and potential economic benefits. Available worldwide, E-band point-
    to-point, line-of-sight microwave radios--also known as millimeter wave (mmWave)
    radios--operate in the unlicensed 57-64 GHz frequency band at data rates up to
    1 Gbps, and in the lightly licensed 71-86 GHz frequency band and 92-95 GHz
    frequency band at data rates up to 10 Gbps. Such functionality makes them ideal for
    dense urban environments (less than 1 km), as well as, industrial suburban environ-
    ments (2-5 km). And, it's a key reason why analysts project a significant jump in the
    mmWave backhaul market in coming years, driven largely by the increased use of
    mmWave for Long Term Evolution (LTE) small cell backhauls.

    Problem
    There are a number of reasons why today's operators might want to migrate to an
    E-band backhaul. Such solutions offer more bandwidth in higher frequency bands
    and feature an antenna beam that is very directional and easy to control. Additionally,
    the frequency bands in which E-band radios operate, namely 60 GHz and 70-90 GHz,
    are now open to commercial services and products.

    Despite these advantages, there are also a number of design and test challenges
    that can be expected as this transition occurs. For example, the extremely narrow
    beam width of E-band leaves the signal potentially vulnerable to building sway and
    atmospheric interference. It also makes aligning systems very difficult. And, E-band
    is very susceptible to degraded performance caused by the rain and oxygen absorp-
    tion. The rain essentially interferes with the E-band's radio wave transmission, forcing
    it to repeatedly transmit data to achieve a reasonable level of service. It even has the
    potential to cause an interruption in service. On top of this, the cost of testing E-band
    backhaul solutions is extremely high.
Solution                                        mmWave Network                                    measurements that can be made include
                                                                                                  true mode, time domain, power, power
With advances in mmWave technology
                                                Analysis Solution                                 sweep (single frequency), power spectrum,
triggering the shift from using traditional                                                       intermodulation distortion, and noise figure,
                                                Keysight's N5251A single sweep, 10 MHz
backhaul (e.g., optical and microwave                                                             among others. The 2- or 4-port PNA/PNA-X
                                                to 110 GHz vector network analyzer solution
links) to E-band point-to-point links,                                                            VDI-based banded waveguide system is
                                                employs a mmWave test controller and
having appropriate, cost-effective test and                                                       used for THz imaging and is configured
                                                a combination of broadband frequency
measurement instruments in place is now                                                           using frequency extenders from Virginia
                                                extenders that provide a male 1.0 mm test
more important than ever. Such solutions                                                          Diodes Incorporated (VDI) that extend the
                                                port output connector. The N5251A is avail-
are critical to ensuring proper operation of                                                      frequency range to 950 GHz.
                                                able as a single product solution. However,
the E-band backhaul, while also addressing      it can also be configured using the PNA           These banded mmWave solutions use built-
the challenges previously outlined.             or PNA-X network analyzer for a lower             in firmware to leverage software between
An effective mmWave test and measure-           cost solution. Existing N5227A PNA and            the PNA and PNA-X Series network
ment strategy must comprise both network        N5247A 67 GHz PNA-X users simply need             analyzers. Regardless of the frequency
analysis for mmWave component test and          to add the N5261A/N5262A test controller          range of the measurements being taken,
calibration, as well as, appropriate signal     and broadband frequency extenders to be           the instruments can be manually controlled
generation and analysis to properly test        able to cover single sweep 10 MHz to 110          from the front panel. A mouse can also be
and measure communication links (e.g.,          GHz measurements.                                 used to access simple pull-down menus.
the transmitter, signal path and receiver).                                                       Using the firmware interface, it is easy to
                                                The N5251A mmWave solution is the
The network analysis solution must provide                                                        switch between frequencies
                                                only broadband solution with integrated
a single-sweep measurement capability,                                                            for measurements.
                                                tri-axial bias tees, which provide accurate
enable full mmWave port power control           control of the device bias through its force/
and support for true differential measure-      sense ability. Its broad frequency enables
ments. The signal generation and analysis       superb time-domain resolution and enables
solutions, on the other hand, should offer      accurate leveled power to be applied to
fast measurement times and switching            the device being measured, allowing users
speeds, scalability to enable the tools to be   to sweep the power at the 1.0 mm port.
tailored to the users changing test needs       Additionally, the N5251A features a range
and flexibility to ensure they support both     of calibration choices for coax, in-fixture and
current and future formats.                     on-wafer devices.
One group of instruments meeting this           To make S-parameter measurements up
criteria is Keysight Technologies, Inc.'s       to 1.1 THz, a variety of easily configurable
mmWave product portfolio. The portfolio         banded mmWave solutions configured from
features both a mmWave network                  the PNA and PNA-X network analyzers
analyzer solution, as well as, one for signal   can be used. The 2- or 4-port OML-based
generation, signal analysis and signal path     banded waveguide system features the
emulation. The network analyzer solution        PNA-X and frequency extenders from OML
is ideal for mmWave device characteriza-        Incorporated that cover a range of 50 GHz
tion, modeling and parameter extraction         to 500 GHz. It may be configured with or
in coaxial or on-wafer, while the signal        without a test set controller depending
generation/analysis solution is well suited     on the measurements required and the
for testing mmWave communications links.        frequency extenders being used. Specific




                                                                      2
Network Analyzer                                                                              RF 1 Out
                                                                                                                                RF 2 Out
                                                                                                                                                            IF inputs




Measurement Example                                                                                                                             R       A       B       C    D




                                                                                                                                                                                                    LO

To gain a better understanding of how                                                                                        OUT 1                              OUT 2
                                                                                                                                                                                                                        Pulse generators

a measurement might be taken with the
                                                                                OUT 1                    OUT 2
                                                                                                                                                                                                                                    1
                                                                                                                                      Source 2
                                                                                                                                                                                                                                        2
                                                                                        Source 1
mmWave network analyzer solution,
                                                                                                                                                                                                                                                3
                                                                                                                                                                                                                                                    4

                                                                 R1                                      R3                                                 R4                                             R2
consider a N5251A solution that has                                                           A                                              C                                                       D                                  B
been configured from a 4-port PNA
network analyzer and allows single-sweep       Test Set
                                               Interface
                                                                      Test port 1
measurements from 10 MHz to 110 GHz                                                                                         Test port 3         IF outputs                                                            Test port 2
                                                                                                                                                                                      Test port 4


(Figure 1). The N5251A has the ability to
                                                                                        ALC                                                                                                                ALC

control and use receiver leveling to set the
                                                                                                                        ALC
                                                                                                                                      R     A       B       C       D
                                                                              RF                                 RF                                                                                 LO
                                                                                                                                                                                                                           Module Power

power accurately at the 1.0 mm test port.
                                                                                                                                          IF Multiplexer
                                                                                                                                                                                                                                            +


Also, it supports measurement applications                                                                                                                                                                                                  -


like true differential measurements, pulsed
measurements and scalar mixer measure-                                                                                        R1 T1 R2 T2 R3 T3 R4 T4
                                                                                                                                M1         M2           M3                  M4
                                                                                                                                                                                             M1      M2   M3     M4   M1 M2 M3 M4



ments, and has the flexibility to enable a
single touchdown for on-wafer components                              M1
                                                                            Frequency Extender
                                                                                                                 67 GHz
                                                                                                                 Combiner
                                                                                                                                                                                      67 GHz
                                                                                                                                                                                      Combiner
                                                                                                                                                                                                    Frequency Extender
                                                                                                                                                                                                                               M2


that completely characterizes the behavior                                                                    SRC     TST (A)
                                                                                                                                      1.0 mm Connectors
                                                                                                                                                                                  TST (B)         SRC



of the device being measured.                                         M3
                                                                            Frequency Extender
                                                                                                                 67 GHz
                                                                                                                 Combiner
                                                                                                                                                                                    67 GHz
                                                                                                                                                                                    Combiner      Frequency Extender
                                                                                                                                                                                                                             M4



                                                                                                              SRC           TST (C)
                                                                                                                                                                                 TST (D)            SRC

With the N5251A's ability to accurately
control power, gain-compression measure-
                                               FIGURE 1. Shown here is the block diagram for the 4-port 110GHz N5251A mmWave network analyzer
ments at mmWave frequencies are much           based on the N5227A PNA.
simpler. As an example, Figure 2 shows
a power sweep being used to perform a                                                                                                                                                       FIGURE 2. This graph illustrates
110 GHz buffer amplifier measurement,                                                                                                                                                       the application of a power sweep
                                                                                                                                                                                            gain compression measurement
while also doing a traditional S-parameter
                                                                                                                                                                                            at 77 GHz.
measurement.

Mixer measurements and power spectral
measurements can also be easily made
with this configuration of the N5251A.
Figure 3a shows the PNA performing a LO
power sweep of a 75 to 110 GHz down
converter mixer at a continuous wave of
75 GHz. Power spectral measurements are
made using the PNA's built-in IM spectrum
option. Figure 3b shows the measurement
of the input and output spectrum of a 110
GHz buffer amplifier measured across the
frequency range from 10 MHz to 110 GHz.



                 FIGURE 3b.
              Shown here is
         input/output of an
        amplifier at 77 GHz.
         With the PNA's IM
           spectrum option,                                                                                   FIGURE 3a. This S21 plot results while sweeping the LO from
          all spectral power                                                                                  -20 to +11 dBm at a mmWave frequency of 75 GHz.
        components can be
       measured across the
         10MHz to 110 GHz
           frequency range.

                                                                       3
mmWave Signal                                     Controlling PC                                                     M8190A wideband AWG

Generator and                                     (Could be desktop, laptop or embedded)

                                                  MATLAB
                                                                                                   Waveform


Analysis Solution                                                                                                                                                                                    Differential IQ AWG to PSG

                                                                                                                                                                                                                      PSG: E8267D-520-016 (I/Q modulation)



mmWave signal generation and analysis,                                                                                                                                                                                        IF-RF up-converter

                                                                                                     Differential IQ
as well as, signal path emulation, is pos-                                                           AWG to Scope
                                                                                                                                                                                                                                     Up-converter

                                                                                                                     MXG1: N5183B -520 (Tx LO)
sible using Keysight's M8190A wideband
arbitrary waveform generator (AWG),                                                                                                                                                                                                                          DUT

PSG signal generators, PXA/EXA spectrum




                                                                                           Demod
                                                   89601B VSA SW
                                                                                                                   MXG2: N5183B-520 (Rx LO)
analyzers, and high-performance Infiniium                                                                                                                                                                                          Down-converter


Series oscilloscope with the 86901B                                                                                                                                                                                               RF-IF down-converter


vector signal analysis software (Figure 4).                                                         Acq'd signal
                                                                                                                      WARNING : Exi t 89 600 V SA So ftwar e bef ore chang ing i nstru ment setu p




Consider, for example, the evaluation                                                                                                                                                                                  DSA91304A Infiniium oscilloscope
of a transceiver. Testing the transceiver
requires a simulated transmitter and/or
                                               FIGURE 4. This block diagram depicts the overall modulated signal generation and analysis solution
a simulated receiver. Ideally, both should
                                               that can be used for mmWave backhaul measurements and analysis.
be flexible enough to generate real world
distortions on the source side and com-
pensate for them on the sink side. With
the M8190A high-performance arbitrary
waveform generator working at 12 bit and
12 GSa/s or at 14 bit and 8 GSa/s, users
have the ability to create these types of
waveforms to use as a test source. The
vector PSG signal generator acts as an
external I/Q modulator. On the analyzer
side, an Infiniium oscilloscope is used with
its support for up to 63 GHz of real-time
frequency bandwidth. The PXA and/or
EXA with 160-MHz RF analysis bandwidth,        FIGURE 5. Analysis of the transceiver produces a 64-QAM constellation with 3 GSymbols/s and a
                                               Q-eye and I-eye diagram on a 86 GHz communication link.
together with a Keysight smart mixer could
also be another choice--depending on
the signal bandwidth and frequency. The
                                               Summary of Results                                                                    The Power to
test solution also includes software con-
                                               Ongoing advances in mmWave technol-
                                                                                                                                     Accelerate Wireless
sisting of MATLAB support for customized                                                                                             Design and Test
                                               ogy are helping to shift backhauls away
signal creation, Signal Studio support for
                                               from traditional technology and toward
specific signal formats such as LTE, and the                                                                                         Keysight is a leader in wireless test,
                                               more economical, high-capacity E-band
89601B software for signal analysis.                                                                                                 focused on the highest-performance
                                               point-to-point links. Unfortunately, the
                                               challenges associated with these links                                                design and test of wireless devices and
During actual measurement of the trans-                                                                                              networks, with application-focused
                                               further complicate an already difficult
ceiver, a signal would first be generated by                                                                                         platforms optimized for existing and
                                               design and test process. Fortunately, the
the M8190A AWG or Signal Studio,                                                                                                     emerging standards. Adding to this
                                               N5251A mmWave network analysis solu-
up-converted with a Keysight E8267D                                                                                                  optimal R&D and field support, Keysight
                                               tion for component test and the mmWave
vector signal generator and/or external                                                                                              allows engineers to better understand the
                                               signal generation and analysis solution
third-party upconverter, and then transmit-                                                                                          intricacies of the continuously evolving
                                               for testing communication links, are
ted to the Device Under Test (DUT), in this                                                                                          wireless industry so you can accelerate
                                               helping to make these challenges much
case, an 86 GHz link. Next, it would be                                                                                              your development of products.
                                               less formidable. As a result, they are now
down-converted by an external device,
                                               providing today's engineers with a critical
such as a Keysight smart mixer or third-
                                               tool for ensuring the proper operation of
party downconverter, and analyzed by the                                                                                             To learn more about Keysight's
                                               E-band backhaul, and in turn, helping the
Infiniium oscilloscope, or PXA/EXA using                                                                                             suite of test and measurement
                                               technology's continued proliferation.
89601B vector signal analyzer software                                                                                               products please visit:
(Figure 5).                                                                                                                          www.keysight.com/find/powerofwireless
                                                                              4
05 | Keysight | Solutions for Millimeter Wave Wireless Backhaul - Application Note




Related Applications                                                                                 For more information on Keysight
                                                                                                     Technologies' products, applications or
                                                                                                     services, please contact your local Keysight
  



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo