Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent Setting and Adjusting Instrument Calibration Intervals - Application Note 5991-1220EN c20140725 [6]
<< Back |
HomeMost service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download
Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing.
If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.
Image preview - the first page of the document
>> Download Setting and Adjusting Instrument Calibration Intervals - Application Note 5991-1220EN c20140725 [6] documenatation <<Text preview - extract from the documentKeysight Technologies
Setting and Adjusting
Instrument Calibration Intervals
Application Note
Introduction
For every organization that relies on electronic test equipment, the cost of instrument
calibration is sometimes viewed as an expense that could be easily reduced. Calibration
costs--and therefore calibration intervals--are part of a broader discussion that includes
tradeoffs between risk and cost, and between quality and customer satisfaction.
Because the instrument manufacturer provides a recommended calibration interval, there
may be a feeling that this is an arbitrary time span driven by tradition or other motivations.
From Keysight Technologies perspective, a well-defined calibration interval is one that
balances the tradeoffs between the cost and inconvenience of the process and the need
to keep test instruments performing within their specifications. The right cal interval
also reduces the risks that come with inaccurate measurements and erroneous pass/fail
decisions. Ultimately, our overarching goal is to boost your confidence in two areas: in the
results our instruments produce and in the decisions you make based on those results.
Outlining our approach
Keysight Technologies, Inc. uses well-defined processes to set the initial cali-
bration interval and then assess the possibility of extending that interval. Below,
we outline the method used prior to the introduction of a new product and also
describe the process we use after a full two years of calibration data is available
for a specific model.
This information will be of interest to at least two distinct groups. One is any
organization that uses outside service providers and wants to reduce costs
without adversely affecting product quality or system performance. The other is
self-maintainers seeking guidance regarding internal management of calibration
intervals for their instrument pool. Both groups will find answers in the pages
that follow.
Setting the initial calibration interval
Prior to the introduction of a new product, the responsible R&D and quality engi-
neers set the initial recommended calibration interval. They do this by looking at
reliability data from at least three areas:
◦ Jabse Service Manual Search 2026 ◦ Jabse Pravopis ◦ onTap.bg ◦ Other service manual resources online : Fixya ◦ eServiceinfo