Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent U1273-90004 English _ 2013-09-03 _ PDF 1.77 MB c20130905 [20]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
U1273-90004 English _ 2013-09-03 _ PDF 1.77 MB c20130905 [20]


>> Download U1273-90004 English _ 2013-09-03 _ PDF 1.77 MB c20130905 [20] documenatation <<

Text preview - extract from the document
                          Agilent U1273A/U1273AX
                          Handheld Digital Multimeter


                          Quick Start Guide




        Verify that you received the following items in the shipment of
        your multimeter:
            One pair of red and black test leads
            One pair of 4 mm test probes
            One K-type thermocouple lead kit
            Four 1.5 V AAA alkaline batteries (for U1273A) or lithium
            batteries (for U1273AX)
            Printed copies of the Certificate of Calibration (CoC) and
            the U1273A/U1273AX Quick Start Guide (this manual)
        If any item is missing or damaged, keep the shipping materials
        and contact the nearest Agilent Sales Office.

NO TE
        The descriptions and instructions in this guide apply to the
        U1273A/U1273AX handheld digital multimeter.
        All related documents and software are available for download
        at www.agilent.com/find/hhTechLib.



                                     Agilent Technologies
U1273A/U1273AX Handheld Digital Multimeter
Install the Batteries


Install the Batteries
            Your multimeter is powered by four 1.5 V AAA batteries
            (included with the shipment).

            1 Turn the rotary switch to OFF and remove
              the test leads from the terminals.
            2 Lift the tilt stand and loosen the screws
              with a suitable Phillips screwdriver.
            3 Remove the battery cover and observe the
              polarity markings.
            4 Insert the batteries and replace the battery cover and screws.


Turn On the Multimeter
            To power ON your multimeter, turn the rotary switch from the
            OFF position to any other position.




    NO TE
            Your multimeter is capable of remote data logging. To use this
            feature, you will need an IR-USB cable (U1173A, purchased
            separately) and the Agilent GUI Data Logger Software (down-
            loadable from www.agilent.com/find/hhTechLib).



            Auto Dim
            By default, the multimeter's Auto Dim function is enabled. The
            multimeter's backlight will dim automatically after 90 seconds
            of inactivity. Press any button to cancel this effect and reset
            the Auto Dim timer.
            You may change how the multimeter's backlight behavior
            through the Setup menu. Refer to the User's Guide for further
            instructions.

2                                     U1273A/U1273AX Quick Start Guide
                     U1273A/U1273AX Handheld Digital Multimeter
                                     The Multimeter at a Glance


The Multimeter at a Glance



                                    Display screen



                                    Keypad



                                    Rotary switch



                                    Input terminals




                                   Test lead/probe holders

                                   IR communication port



                                   Battery cover
                                   (Lift tilt stand for access)

                                   Tilt stand




U1273A/U1273AX Quick Start Guide                                  3
U1273A/U1273AX Handheld Digital Multimeter
Understanding the Rotary Switch


Understanding the Rotary Switch




    NO TE
            Press      to switch between the primary and shifted func-
                       Shift
                   Esc View



            tions shown on the rotary switch.


              Legend Description

               ZLOW            ZLOW (low input impedance) AC/DC V for eliminating
                               ghost voltages

                               Off
                               AC V
                               AC V with Low Pass Filter
                               AC mV
                               AC mV with Low Pass Filter
                               DC V
                               AC V or AC+DC V
                               DC mV
                               AC mV or AC+DC mV
                               Resistance
               Smart
                               Continuity or Smart  (offset compensation)
                               Diode
                 Auto
                               Auto-diode
                               Capacitance
                               Temperature
                               DC mA (or A)
                               AC mA (or A) or AC+DC mA (or A)
                               DC A
                               AC A or AC+DC A

4                                             U1273A/U1273AX Quick Start Guide
                          U1273A/U1273AX Handheld Digital Multimeter
                                           Understanding the Keypad


Understanding the Keypad




                                  Key response when pressed for:
           Legend
                          Less than 1 second         More than 1 second
                                                   Sets the Scale mode for
                        Sets the Null/Relative
               Null
              Scale
                                                   the specified ratio and
                        mode.
                                                   unit display.
            MaxMin      Starts the MaxMin          Starts and stops the
             Peak
                        recording.                 Peak recording.
                                                   Automatically freezes
            Trig        Freezes the present
            Auto Hold                              the present reading once
                        reading in the display.
                                                   the reading is stable.
                                                   Exits the Hold, Null,
                        Switches between avail-
              Dual                                 MaxMin, Peak, fre-
              Exit      able dual-combination
                                                   quency test, and dual
                        displays.
                                                   display modes.
                        Increases the OLED
                        brightness incremen-
                                                   Enters and exits the mul-
                        tally when LOW,
              Setup                                timeter's Setup menu.
                        MEDIUM, or HIGH set-
                        ting is selected.
                        Switches between fre-
             Hz % ms
                        quency, pulse width, and   Starts and stops the
               Log
                        duty cycle measure-        Data Logging.
                        ments.
                        Sets a manual range and
               Range                               Enables auto-ranging.
                Auto    disables autoranging.
                        Switches between the
                Shift
                                                   Enters and exits the Log
            Esc View    primary and shifted
                                                   Review menu.
                        functions.




U1273A/U1273AX Quick Start Guide                                               5
U1273A/U1273AX Handheld Digital Multimeter
Understanding the Input Terminals


Understanding the Input Terminals

WA RN ING
            Ensure that the terminal connections are correct for that
            particular measurement function before starting any
            measurement. To avoid damage to the device, do not
            exceed the input limit.



              Rotary position   Input terminals   Overload protection


                                                      1000 Vrms


                   ZLOW




                                                  1000 Vrms for short
                                                     circuit <0.3 A
                   Smart


                    Auto




                                                      11 A/1000 V
                                                    fast-acting fuse


                                                    440 mA/1000 V
                   or                               fast-acting fuse




6                                  U1273A/U1273AX Quick Start Guide
                      U1273A/U1273AX Handheld Digital Multimeter
                              Performing Measurements and Tests


Performing Measurements and Tests

    Voltage measurements
         The figure below highlights the primary functions allowing
         voltage measurements in your multimeter.




         Set up your multimeter as shown in the figure below to per-
         form voltage measurements. When measuring DC voltage from
         a mixed signal in DC measurement mode, ensure that the Filter
         (    ) is enabled.


                 4




                                          3

                                               DC




           2




                        1




U1273A/U1273AX Quick Start Guide                                      7
U1273A/U1273AX Handheld Digital Multimeter
Performing Measurements and Tests


         1 Press    for more than 1 second to enter the multimeter's
                       Setup


           setup menu.
                                                                   Hz % ms
         2 Browse to Menu 6 > Filter, and press                      Log     to edit the
           value.
                        Dual
         3 Press       or
                        Exit   to enable the Filter.
                                       Setup


           Refer to the table below for the respective firmware ver-
           sions.

               Version 1.64 or older                          Version 1.95 or newer
                                  on                                     DC

                        Hz % ms
         4 Press          Log     to save your changes.
         5 Press and hold      until the multimeter restarts and returns
                                        Setup


           to normal operation. Turn the multimeter to DC Voltage
           mode to verify that the LPF symbol is turned on.

                          To avoid possible electric shock or personal injury, enable
          CAU TI O N      the Filter (    ) to verify the presence of hazardous DC
                          voltages. Displayed DC voltages can be influenced by high
                          frequency AC components and must be filtered to assure
                          an accurate reading.


         LPF during AC measurements:
                                                           Shift
                                                Press       while performing AC
                                                       Esc View



                                                voltage measurements to pass the
                                                measured signal through a low pass
                                                filter.

         



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo