Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent Y1226-90001 Y1226A Rack Mount Kit - Installation Gudie c20140923 [6]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Y1226-90001 Y1226A Rack Mount Kit - Installation Gudie c20140923 [6]


>> Download Y1226-90001 Y1226A Rack Mount Kit - Installation Gudie c20140923 [6] documenatation <<

Text preview - extract from the document
Keysight Y1226A Rack Mount Kit Installation
                This installation note contains procedures for installing the Y1226A Rack Mount
                Kit for the Keysight M9505A 5-slot AXIe Chassis in a standard EIA rack.

   Parts List
                The parts included with each rack mount adapter option and the support rail are
                shown in the following table:


                        Quantity    Description                                 Part Number
                        1           Rack Flange Kit                             M9505-00020
                        6           Rack Flange Screws Flat Head                N/A
                        2           Support Rails                               M9018-00001
                        8           Channel Nuts (for support rail-to-rack)     0590-0804
                        4           Support Rail-to-Rack Screws - 10-32 x 0.5   2680-0278
                        4           Dress Adapter Screws for rack flanges       E9900-06001


   General Guidelines
                In rack mounting the chassis, follow these guidelines:
                1 Always begin installing the chassis and heavy instruments at the bottom of
                  the rack and work up. This maintains a lower center of gravity and reduces the
                  possibility of the rack tipping.
                2 Anti-tipping feet, if available with the rack, should always be extended.
                3 The heaviest instrument of chassis should always be mounted at the bottom
                  of the rack.
                4 For maximum cooling and optimum rack thermal efficiency, place the
                  instrument or chassis with the greatest power consumption towards the top of
                  the rack. This promotes efficient cooling since heat rises when placed nearer
                  to the top of the rack, high power instruments will not unnecessarily heat
                  other instruments. However, in doing this, do not violate the guideline that
                  the heaviest instruments should be placed at the bottom of the rack.
                5 If instruments or modules in the chassis are consuming maximum power, 1U
                  of rack space is required for ventilation below the chassis.
    Keysight Y1226A Rack Mount Kit Installation




       Procedure
                      1 The M9505A AXIe chassis has two carry handles which must be removed
                        before removing the plastic bumpers. Remove the two #2 Phillips screws
                        securing the carry handles.See Figure 1.
                      2 Remove the #2 Phillips screws from each side of both bumpers. See Figure 1.




                                            Figure 1 . Removing the Carry Handles and Bumpers




2                                                                      Keysight Y1226A Rack Mount Kit Installation Note
                                                                              Keysight Y1226A Rack Mount Kit Installation




                          3 Remove the three #1 Phillips flat head screws from the top of each bumper.
                            See Figure 2.




                                                   Figure 2 . Removing the Chassis Bumpers


                          4 Carefully turn the chassis onto it's top. Remove the four plastic feet from the
                            bottom of each bumper. Each foot is attached to the chassis through the
                            bumper with a small #2 Phillips screw retained at the back of the foot with a
                            plastic washer. Loosen each screw just enough to disengage it from the
                            chassis. The foot, screw and washer will remain intact. See Figure 3.




                                                   Figure 3 . Removing the Chassis Bumpers


Keysight Y1226A Rack Mount Kit Installation Note                                                                     3
    Keysight Y1226A Rack Mount Kit Installation




                      5 Slide the bumpers off the chassis.
                      6 Using the rack mount flanges as templates, position the flanges on the rack's
                        vertical columns where the chassis is to be mounted. Align the adapter holes
                        over the "center" holes of the EIA rack units. Slide channel nuts over the rack
                        holes to be used by the rack mount flanges. See Figure 4.



                Rack Unit
                Center Hole




               Channel
                                                                                     One
               Nuts
                                                                                     Rack
                                                                                     Unit




                              Figure 4 . Center Holes of EIA Rack, Attaching Channel Nuts




4                                                                       Keysight Y1226A Rack Mount Kit Installation Note
                                                                               Keysight Y1226A Rack Mount Kit Installation




                          7 Attach the rack mount front handle flanges to the chassis. Refer to Figure 5.




                                                                                         Three Flathead
                                                                                         Screws




                                 Figure 5 . Attaching Rack Mount Flanges to M9505A Chassis
                          8 Position the rails on the rack's vertical columns where the chassis is to be
                            mounted. Align the adapter holes over the "center" holes of the EIA rack units.


                                          INSTALL THE SUPPORT RAILS UPSIDE DOWN IN THE RACK! To
                                          provide adequate air flow to the ventilation holes on the sides of
                                          the chassis, you must install the rack slides upside down as
                                          shown in Figure 6.


                          9 Slide channel nuts over the rack holes to be used by the support rails.
                          10 Attach the support rails UPSIDE DOWN to the rack's inside vertical columns.
                             Use four channel nuts and the four 10-32 x 0.5 support rail-to-rack pan head
                             screws as shown in Figure 4.
                          11 Set the chassis onto the support rails.


                                          To prevent injury d uring rack mounting, the chassis should
                                          be empty and two people should lift the chassis into the
                                          rack.




Keysight Y1226A Rack Mount Kit Installation Note                                                                      5
12 Slide the M9505A chassis into the rack until the rack mount front handle
   flanges are against the rack's vertical columns. Secure the chassis to the rack
   using the adapter dress screws.

              If the rack will be moved excessively or over long distances, you
              should use a strap to secure the chassis to the rack slides.




                                                                    10-32 x 0.5 screws




           Figure 6 . Attaching the Support Rails to the Rack.




                                This information is subject to change without notice.
                                                       



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo