Service Manuals, User Guides, Schematic Diagrams or docs for : Akai DV DV-R4035VSMC DV-R4035VSMC

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
DV-R4035VSMC


>> Download DV-R4035VSMC documenatation <<

Text preview - extract from the document
DVD/CD/TUNER/AMPLIFIER
               PLAYER



                Model:
         DVR4035VSMC


  SERVICE MANUAL




               www.akai.ru
DVD/ CD/TUNER/AMPLIFIER PLAYER
         DV-R4035VSMC

     SERVICE MANUAL
Table of contents

Safety information----------------------------3                 8Control board silk screen diagrqm--------------------------33

    1 General guide---------------------------3
    2 Low zeta potential leaking inspection------3               Attachment 3------------------------------34
    3 High zeta potential leaking inspection------3

                                                                     Component list
    Device avoiding ES (Electric susceptible)                   1 Decoder board component list------------------35

       Influence of ESD (Electric Susceptible                   2 Amplifier board component list----------------38

Discharge)----3                                                 3 Control board component list-------------------41

 Electric specification-------------------4
 Mechanical diagram---------------- -------8
      Mechanical parts list-------------------- 9
 Packing and accessories--------------10
 Disassemble and assemble-----------11
      1 Take out disc from trouble player-------11

      2 PCB position------------------------11
    Disassemble and assemble parts of the unit----12

      1 Can open the tray by electricity---------12

      2 Can not open the tray by electricity-----12

      3 Assemble the case-------------------------12

    Attachment 1------------------------- 13

    Block diagram/Circuit diagram--------13

    1 Block diagram--------------------------------14
    2 Connecting diagram-------------------------15

    3 Decoder board diagram---------------------16

    4 Amplifier board diagram-------------------21

    5 Control Board diagram---------------------24



    Attachment 2-------------------------25

    PCB diagram

      1 Upper decoder board PCB diagram----26

      2 Upper decoder board silk screen diagram-------27

      3 Lower decoder board PCB diagram-------------28

      4 Amplifier board PCB diagram-------------------29

      5 Amplifier board silk screen diagram------------30

      6 Upper control board PCB diagram-------------31

      7 Lower control board PCB diagram------------32


                                                            2
Safety information
General guide                                                               of discharge     of distortionESDexceeded the
1.Observe the original circuit during maintenance. If short                 restrained figure, electric shock should be
circuit occurs, change the over-hot or damaged components.                  possibly suffered. Do maintain the unit and
2.Observe all the protective device after maintenance, such                 inspect once more before return to the user.
as whether the shielding cover or paper is assembled well.                Device avoiding ES influence of ESD.

3.To avoid electric shock, please inspect electricity leakage                  Some solid semi-conductor devices are easy to be

after maintenance                                                         damaged by static electricity. These devices are generally

Low zeta potential leaking inspection                                     called ES device. The typical devices are IC, field effect

1.Take out AC cord and connect a piece of wire between two                component and semi-conductor laser diode.

legs of the outlet.                                                            The following technology helps to abate         the danger of
                                                                          ESD on body before handle any semi-conductor or
2.Use Gear R x 10K of the voltmeter to measure the spares
                                                                          semi-conductor component. Or wear the ESD bangle availed
on AC outlet and exposed metallic part with short circuit.
                                                                          from the market to eliminate the threaten of static electricity
The resistance between screw cap, control shaft should be                 on human body.
unlimited.
                                                                          2.Put the electronic parts with ES device on the surface of

                                                                          conductor such as aluminium foil after take them out in order
                                  AC voltmeter
    Electric leakage inspection
                                                                          to protect static electricity from accumulation and explosion.
                                                                          3.Solder or disassemble ES device through iron connecting
                                                                          the earth.
                                                                          4. Utilize device only anti-static electricity to disassemble
                                                                          soldering tin. Non-anti static electricity device (ESC
                                   0.15uF
                                                                          protection) will release ES that damage ES device.
                                                                           5.Do not use chemical volatile releasing static electricity
                                  1.5K 10W
                                                    Cold water pipe
  To device with                                  connecting to
  exposed metal parts                             ground                  that leads to damage ES device

                                                                          6. Unless preparation for pre-assembling has been made,do
                                   Picture1                               not take out the ES device to be changed from the protective
High zeta potential leakage inspection                                    packings( most of the changed ES devices are packed
 .As illustrated 1, Connect Resistor with 1.5K, 10W and
                                                                          together with anti-static electrical foam or similar electric
capacitor 0.15 between exposed metallic part and device of
                                                                          material, besides, countermeasures for down-lead short
fine connection to the earth (water pipe etc.).
                                                                          circuit are taken.).
2.Plug-in AC cord directly to AC outlet. Do not inspect with
shield adaptor.                                                           7. Protective material should connect the model or the circuit

3.Utilize 1000 or more sensitive voltmeter to measure                     component to be assembled in it before taking out the
alternating voltage.                                                      protective material from the ES device.
4.Turn back the AC plug-in from AC outlet then iterate the                Note: do not bear electricity to the model or the circuit, and
inspection as above.                                                      pay attention to all the other safety information.
5.Inspect the voltage of the resistor between other exposed               8. When disassembling and replacing the ES device, try to
metallic parts and the earth with the same way.
                                                                          reduce body movement (Or, the movement of legs, the
6. The voltage must not be over than 0.75Vrms at any points               friction of fibrous of clothes, or elevating the legs from the
on the resistor. Electric leakage should not be over 0.5mA                floor will generate static electricity ESD, causing damage to
when processing high voltage leakage testing through                      the ES device.)
prevent ed static of keennessESsetting is exposedto static



                                                                      3
                                      Electric Specification
    MW electric index                       Model No.: DVP-0601-1
    Test condition:
    1. Supply voltage: AC230V 50Hz          2. Standard power output: 1W
    3.Speaker impedance: 4FLFRSLSR   8C 6(SW)
    4.Standard modulating: 400Hz 30%
No.                      Test items    Unit     Standard         Limit                  error
1    Intermediate frequency                               KHz      450                  +/-3
2    Cover with area                                      KHz    522-1620               +/-5
                            S/N 20dB612KHz                uV/M     600        3000
4    Utility delicacy       S/N 20dB999KHz                uV/M     600        3000
                            S/N 20dB1395KHz               uV/M     600        3000
5    S/N ratio999 KHzinput 5mV/M                           dB      40          30
6    Intermediate Frequency restrain rate612KHz            dB      45          35
7    Mirror restrain rate1404KHz                           dB      35          30
8    Auto plus controlinput 100mV/M                        dB      30          20
     Distortion    5mV/M input30                           %        1          3
9
     degree        100mV/M input80                         %        3          5
10   -6dB bandwidth20dB S/N                               KHz       8         5-10
11   zip    input 5mV/MIFx1           IFx2                 %        3          10
                   Volume max                              W
     Output
12                 Distortion degree: 10%60% modulation
     power                                                 W       4.5         3
                   degreeinput 5mV/M
13   +/-10KHz selectivity     1000KHz     20dB   S/N       dB      14          8
14   Frequency respond      -6 dBinput 5mV/M               Hz     40~4K     100~3.15K
15   Modulating AC volume         input 100mV/M            dB      40          35
16   The least noise                                      mV        1           3
17   Sensitivity of station locking                        dB                 90




                                                 4
        FM electric index                    Model No.: DVP-0601-1
    Test condition:
    1. Supply voltage: AC230V 50Hz  2. Standard output power: 1W
    3. Antenna impedance: 75       4. Standard modulating: 1KHz 22.5KHz
    5. Speaker impedance: 4FLFRSLSR8C        6(SW)
No.                     Test items         Unit     Standard      Limit          Error
1    Intermediate frequency                            MHz     10.7              +/-0.1
2    Cover with area                                   MHz   87.5-108            +/-0.1
                           S/N 30dB90MHz               dB       22        26
3    Utility delicacy      S/N 30dB98MHz               dB       22        26
                           S/N 30dB106MHz              dB       22        26
4    S/N ratio 98MHzinput 1mV                          dB       50        34
5    -3dB limit delicacy                               uV       10        20
6    Intermediate Frequency Restrain Rate90MHz         dB       50        45
7    Mirror Restrain Rate106MHz                        dB       28        22
8    Distortion degree      1mV input                  %       0.6       1.5
9    Modulating AC volumeinput 5mV                     dB       50        40
10   Auto frequency control range1mV input-3dB         KHz
11   AM restrain1mv inputmodulate degree 30%           dB       32        26
12   Power outputdistortion degree 10%60KHz1mv input   W        10
13   Frequency response-3dB                            Hz    40~12.5K   100~8K
14   Noise of minimum volume                           mV       1         3
15   Sensitivity of station locking                    dB                35
16   Passage separating                                dB       25       20




                                               5
    DVD electric index                                                                      Model No.: DVP-0601-1
    1Video section
 No.                Test item                 Test point           Performance require        Unit             Remark
 1                        Video                                            1.0



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo