Service Manuals, User Guides, Schematic Diagrams or docs for : Akai LCT LCT-42Z6TM LCT-42Z6TM

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
LCT-42Z6TM


>> Download LCT-42Z6TM documenatation <<

Text preview - extract from the document
                                            AKAI

                SERVICE MANUAL

                                     Model: LCT42Z6TM

1.    Safety Instructions...............................................................................1~2
2.    Trouble Shooting manual of LCD.............................................................3~4
3.    Product Specification............................................................................5~7
4.    Block Diagram...................................................................................8~9
5.    Circuit diagram..................................................................................10~17
6.    Basic Operation & Circuit Description......................................................18~20
7.    Main IC Information...........................................................................21~39
8.    Panel Information..............................................................................40~68
9.    Explored View.................................................................................69
10.   Spare Pare List.................................................................................70~72
11.   Software Upgrade..............................................................................73~75




               This manual is the latest at the time of printing, and does not
               include the modification which may be made after the printing,
               by the constant improvement of product.
I. Safety Instructions

                                                                            The l ig h tn i ng fla sh w i th arro wh e ad symb ol ,
                                                                            within an equilatera l triangle, is intended to alert
                         CAUTION                                            the user to the presence of uninsulated " dangerous
                                                                            voltage" within the prod uct' s enclosure that may
                 RISK O F ELECT RIC SHO CK                                  be of sufficie nt mag nitud e to consti tute a risk of
                      DO NO T O PEN                                         electric shock to persons.

                                                                            The excla mati on po i nt wi thi n a n e q ui l ate ra l
   CAUTION: TO REDUCE THE RISK OF ELECTRIC                                  tri a n gl e is i nte n de d to a le rt th e u se r to th e
   SHOCK, DO NOT REMOVE COVER (OR BACK). NO                                 presence of important operating and maintenance
   USER-SERVICEABLE PARTSINSIDE. REFER                                      (s e rv i ci n g ) i n str u ct i o n s i n th e l i te r a tu re
   SERVICING TO QUALIFIED SERVICE PERSONNEL                                 accompanying the appliance.
   ONLY.


PRECAUTIONS DURING SERVICING                                           SAFETY INSTRUCTION
1. In a ddition to safe ty, othe r parts and assemblies are               The se rvice shoul d not be attempted by anyone
   speci fied for conformance with such regulatio ns as                   unfamiliar with the ne cessary i nstructio ns on th is
   those applyi ng to sp urious radiation . These must                    monitor. The fo llowing are the necessary instru ctions
   also be replace d only with specifie d replacements.                   to be ob served before se rvicing.
   Exampl es: RF converters, tun er units, a ntenna                    1. An isolation transformer shoul d be con nected i n the
   selection switches, RF cables, noise-blo cking                         power li ne between the receiver and the AC line
   capacitors, noise-bl ocking filters, etc.                              when a service is performed o n the primary of the
2. Use sp ecified inte rnal Wiring . Note especially:                     conve rter tra nsformer of the set.
   1) Wires covered with PVC tubing                                    2. Comply wi th all caution an d safety related provided
   2) Do uble insulated w ires                                            on th e back of the cabi net, inside the cabinet, o n the
   3) Hig h voltage leads                                                 chassis or p icture tube.
3. Use specified i nsulating material s for haza rdous                 3. To avo id a shock hazard, alw ays discharge the
   live pa rts. Note espe cially:                                         pictu re tube's anode to the chassis g round be fore
   1) In sulating Tape                                                    removi ng the anod e cap.
   2) PVC tubing
   3) Spa cers (insu lating barriers)
   4) Insula ting sheets for transistors
   5) Plastic screws for fixing micro switches
4. When replacing AC primary side compo nents
   (tran sformers, power cords, n oise blo cking
   capacitors, e tc.), wra p ends o f wires securely about
   the te rminals be fore solde ring.




5. Make sure that w ires do no t contact heat generating
   parts (he at sin ks, oxide me tal fi lm resistors, fusi ble
   resistors, etc.)
6. Check if replace d wires do not conta ct sharply edged
   or po inted pa rts.
7. Make sure that foreign objects (screws, solder
   drop lets, etc.) do not remain insi de the set.

MAKE YOUR CONTRIBUTION TO PROTECT THE
ENVIRONMENT
    Used batte ries wi th the ISO symbol
    for recycling a s well as small
    accumu lators (re chargeable batteries), mini-batteries
    (cell s) and starter b atteries should not be thrown
    into the garbage can.
    Please leave the m at an ap propriate depot.


                                                                 -2-


                                                              175
4. Completely discharge the high pote ntial voltage of the                      PRODUCT SAFETY NOTICE
   picture tube before handli ng. The pi cture tube is a
                                                                                  Many e lectrical an d mechanica l parts in this
   vacuum and if bro ken, the gl ass will explode.
5. When rep lacing a MAIN PC B in the cabinet, always                             monitor have special safety-related characteristics.
                                                                                  These characteri stics are offer passed unnoticed by
   be certai n that all protective are installed properly
                                                                                  visual spection and the protecti on afforded by them
   such as co ntrol knobs, adjustment co vers o r shie lds,
   barri ers, iso lation resistor networks etc.                                   cannot necessari ly be obta ined by using replacement
                                                                                  compon ents rates for a hig her voltag e, wattage , etc.
6. When se rvicing is re quired, observe the origin al lead
                                                                                  The replacemen t parts w hich have these sp ecial
   dressing. Extra precau tion sho uld be gi ven to a ssure
   correct lead dressing in the high voltage area.                                safety characteristics are identifie d by      marks on
                                                                                  the schematic diag ram and on the parts l ist.
7. Keep wires away from high voltage or high te mpera
                                                                                  Before replacin g any of these compo nents, rea d the
   ture compone nts.
8. Befo re returning the set to the customer, al ways                             parts list in thi s manua l care fully. The use of
                                                                                  substitute re placemen t parts which do not have the
   perform an AC leaka ge current check on the exposed
                                                                                  same safety chara cteristics as speci fied in the p arts
   meta llic parts of th e cabine t, such as anten nas,
   termin als, screw heads, meta l overlay, control shafts,                       list may cre ate shock, fire, X-RAY RADIATION or
                                                                                  other h azards.
   etc., to be sure the set i s safe to operate without
   danger of electrica l shock. Plu g the AC lin e cord
   directly to the AC outlet (do not use a line iso lation
   transformer d uring th is check). Use an AC voltmeter
   havin g 5K ohms volt sen sitivity or more i n the
   following manner.
   Conne ct a 1.5 K ohm 10 watt resistor pa ralleled by a
   0.15