Service Manuals, User Guides, Schematic Diagrams or docs for : COMPAQ Monitor Compaq P75

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Compaq P75


>> Download Compaq P75 documenatation <<

Text preview - extract from the document
                                                                                                                    P75

                                                                                                                P75
   SERVICE MANUAL
                                                                                        US Model
                                                                                  Canadian Model
                                                                                        UK Model
                                                                                      AEP Model
                                                                             N. Hemisphere Model
                                                                             S. Hemisphere Model
                                                                                 Australian Model
                                                                                                Chassis No. SCC-L07E-A




                                                                                   D-1H CHASSIS
                                                     SPECIFICATIONS

Picture tube          0.25 mm aperture grill pitch                 Power Consumption
                      17 inches measured diagonally                        Maximum                 115W
                      90-degree deflection                                 Nominal                 100W, 341 BTU/h

Video image area      (16" maximum viewing image)                  Deflection frequency            Horizontal: 30 to 85 KHz
                      Approx. 329.5 x 243 mm (w/h)                                                 Vertical: 50 to150 Hz
                      (13 x 9 5/8 inches)
                                                                   AC input voltage / current      100 to 120 V, 50/60 Hz, 1.8 A
Max. resolution       Horizontal: Max. 1280 dots                                                   220 to 240V, 50/60Hz, 1A
                      Vertical: Max. 1024 lines
                      (at 75 Hz Refresh Rates)                     Dimensions                      424 x 422 x 428 (w/h/d)
                                                                                                   (16.7 x 16.6 x 16.9 inches)
Standard image area   Approx. 306 x 230 mm (w/h)(Mode 1-13)
                      Approx. 294 x 231 mm (w/h)(Mode 14-15)       Mass                            Approx. 18.48 kg (40.8 lb.)

Input signal
          Video       Analog RGB (75 ohms typical)
                      0.7 Vp-p, Positive
         Sync         External HD/VD, Composite
                      Polarity Free TTL                        Design and specifications are subject to change without notice.
                      Video Composite (Sync on Green)
                      0.286 Vp-p, Negative


                                                                                          COLOR MONITOR

                                                           --1--
                                                                                                                                                                                                 P75
         POWER SAVING FUNCTION
                                                                             NOTE:           If no video signal is input to the monitor, the "NO INPUT SIGNAL" message appears.
                                                                                             After about 30 seconds, the Power Saving function automatically puts the monitor into
        This monitor has three Power Saving modes.                                           active-off mode and the indicator lights up orange. Once the monitor detects horizon-
        By sensing the absence of a video signal from the                                    tal and vertical sync signals, the monitor automatically resumes normal operation mode.
        computer, it reduces power consumption as follows:

                                                                                           Power                  Required Recovery
                                                            State                                                                                   u Power Indicator
                                                                                        Consumption                      Time

                                   1 Normal Operation                                        <110W                                                           Green on

                                   2 Standby (1st mode)                                       <15W                    approx. 3 sec.                         Yellow

                                   3 Suspend (2nd mode)                                       <15W                    approx. 3 sec.                         Yellow

                                   4 Active-off (3rd mode)                                     <8W                   approx. 10 sec.                         Amber

                                   5 Power-off                                                 0W                                                               Off
--2--




                                   6 Failure mode                                                                                                      Orange flashing

        TIMING SPECIFICATION

        MODE                    1       2       3       4       5       6       7       8       9       10       11       12       13       14         15
        Resolution (H x V)   640x350 640X480 640x480 640x480 720x400 800x600 800x600 800x600 832x624 1024x768 1024x768 1024x768 1152x870 1280x1024 1280x1024
        Dot Clock (MHz)        25.175  25.175  31.500  36.000  28.321  40.000  49.500  56.250  57.283  65.000   78.750   94.500  100.000   108.000    135.000

        HORIZONTAL
        Hor. Freq. (kHz)      31.469     31.469     37.500     43.269     31.468    37.879    46.875    53.674     49.725     48.363     60.023     68.677     68.681      63.981       79.976
        H-Total               31.778     31.778     26.667     23.111     31.779    26.400    21.333    18.631     20.111     20.677     16.660     14.561     14.560      15.630       12.504
        H-Blanking             6.356      6.356      6.349      5.333      6.356     6.400     5.172     4.409      5.586      4.923      3.657      3.725      3.040       3.778        3.022
        H-Front Porch          0.636      0.636      0.508      1.556      0.636     1.000     0.323     0.569      0.559      0.369      0.203      0.508      0.320       0.444        0.119
        H-Sync.                3.813      3.813      2.032      1.556      3.813     3.200     1.616     1.138      1.117      2.092      1.219      1.016      1.280       1.037        1.067
        H-Back Porch           1.907      1.907      3.810      2.222      1.907     2.200     3.232     2.702      3.910      2.462      2.235      2.201      1.440       2.296        1.837
        H-Active (msec)       25.422     25.422     20.317     17.778     25.423    20.000    16.162    14.222     14.524     15.754     13.003     10.836     11.520      11.852        9.481

        VERTICAL
        Ver. Freq. (Hz)       70.086     59.940     75.000     85.008     70.084    60.317    75.000    85.061     74.550     60.004     75.029     84.997     75.062      60.020       75.025
        V-Total                  449        525        500        509        449       628       625       631        667        806        800        808        915       1066         1066
        V- Blanking               99         45         20         29         49        28        25        31         43         38         32         40         45          42           42
        V-Front Porch             38         10          1          1         12         1         1         1          1          3          1          1          3           1            1
        V-Sync.                    2          2          3          3          2         4         3         3          3          6          3          3          3           3            3
        V- Back Porch             59         33         16         25         35        23        21        27         39         29         28         36         39          38           38
        V-Active (lines)         350        480        480        480        400       600       600       600        624        768        768        768        870       1024         1024

        SYNC.
        Int(G)               NO        NO         NO         NO         NO         NO        NO        NO        NO         NO         NO         NO         NO         NO          NO
        Ext(H/V)/Polarity    YES +/-   YES -/-    YES -/-    YES -/-    YES -/+    YES +/+   YES +/+   YES +/+   YES -/-    YES -/-    YES +/+    YES +/+    YES -/-    YES +/+     YES +/+
        Ext (CS)/Polarity    NO        NO         NO         NO         NO         NO        NO        NO        NO         NO         NO         NO         NO         NO          NO
        Int/Non Int          Non Int   Non Int    Non Int    Non Int    Non Int    Non Int   Non Int   Non Int   Non Int    Non Int    Non Int    Non Int    Non Int    Non Int     Non Int
                                                                                                                                  P75
                                                           SAFETY CHECK-OUT
                                                             (US Model only)


     After correcting the original service problem, perform                   LEAKAGE TEST
the following safety checks before releasing the set to the                        The AC leakage from any exposed metal part to earth ground
customer:                                                                     and from all exposed metal parts to any exposed metal part having
                                                                              a return to chassis, must not exceed 0.5 mA (500 microampere).
1. Check the area of your repair for unsoldered or                            Leakage current can be measured by any one of three methods.
   poorly-soldered connections. Check the entire board
   surface for solder splashes and bridges.
2. Check the interboard wiring to ensure that no wires                        1. A commercial leakage tester, such as the Simpson 229 or
   are "pinched" or contact high-wattage resistors.                              RCA WT-540A. Follow the manufacturers' instructions to
3. Check that all control knobs, shields, covers, ground                         use these instructions.
   straps, and mounting hardware have been replaced.                          2. A battery-operated AC milliammeter. The Data Precision
   Be absolutely certain that you have replaced all the                          245 digital multimeter is suitable for this job.
   insulators.                                                                3. Measuring the voltage drop across a resistor by means of
4. L o o k f o r u n a u t h o r i z e d re p l a c e m e n t p a r t s ,        a VOM or battery-operated AC voltmeter. The "limit"
   particularly transistors, that were installed during                          indication is 0.75 V, so analog meters must have an accurate
   a previous repair. Point them out to the customer                             low voltage scale. The Simpson's 250 and Sanwa
   and recommend their replacement.                                              SH-63Trd are examples of passive VOMs that are suitable.
5. Look for parts which, though functioning, show                                Nearly all battery operated digital multimeters that have a
   obvious signs of deterioration. Point them out to                             2V AC range are suitable. (See Fig. A)
   the customer and recommend their replacement.
6. Check the line cords for cracks and abrasion.                                                       WARNING!!
   Recommend the replacement of any such line cord
                                                                              NEVER TURN ON THE POWER IN A CONDITION IN WHICH THE
   to the customer.
                                                                              DEGAUSS COIL HAS BEEN REMOVED.
7. Check the B+ and HV to see if they are specified
   values. Make sure your instruments are accurate;                                   SAFETY-RELATED COMPONENT WARNING!!
   be suspicious of your HV meter if sets always have                         COMPONENTS IDENTIFIED BY SHADING AND MARK 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo