Service Manuals, User Guides, Schematic Diagrams or docs for : DENON Stereo Power Amplifier Stereo Power Amplifier Denon - POA-3012CI DENON control protocol Ver. 5.1.8

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
DENON control protocol Ver. 5.1.8


>> Download DENON control protocol Ver. 5.1.8 documenatation <<

Text preview - extract from the document
DENON control protocol
                                                                                                         Ver. 5.1.8

  Application model : POA-3012CI
  Application terminal: RS-232C/Ethernet


Connector specification
   . RS-232C
       Connector type: DB-9pin female type, slave straight connection (DCE type)
                     ( 1pin : GND , 2pin : TxD , 3pin : RxD , 5pin : Common(GND) , 4,6,7,8,9pin : NC )
       Communication format:
              Synchronous system           : Tone step synchronization
              Communication system         : A half duplex
              Communication speed          : 9600bps
              Character length                    : 8 bits
              Parity control                      : None
              Start bit                           : 1 bit
              Stop bit                            : 1 bit
              Communication procedure             : Non procedural
              Communication data length    : 135 bytes (maximum)




                                                           -1-
. Ethernet
   Connector type        RJ-45(10BASE-T/100BASE-TX)

    Example

                                            Ethernet
                    PC                     Cross cable               POA-3012CI




    Example                                      HUB


                    PC                                               POA-3012CI
                                    Ethernet           Ethernet
                                    Straight           Straight
                                      cable              cable



   Communication format
          Communication   system          :   A half duplex
          Communication   speed           :   10Mbps/100Mbps
          Communication   port            :   TCP port 23 (telnet)
          Communication   data length     :   135bytes (maximum)




                                                            -2-
NETWORK SETUP of POA-3012CI

>Procedure of Network Setup mode.
(1)Press MENU button and select "system set up" with rotary encoder, then System Setup Menu appears on FL-display.
(2)Select "Network Setup > Detail" .
(3)Set parameters described below.
          "ON"---Use this setting when DHCP server is on the local network.
                "OFF"---Use this setting when DHCP server is not on the local network.
   When  sets "OFF", please set IP address.
                When  sets "ON", you can confirm the IP address that is set by server.
   When  sets "OFF", please set Subnet Mask.
                When  sets "ON", you can confirm the Subnet Mask that is set by server.
       Set the address of Gateway when Gateway is on the local network.
                Do not set this parameter when Gateway is not on the local network.
   Do not set this parameter.
   Do not set this parameter.
         Set this parameter "OFF".

 
  (1)Press MENU button and select "power configuration", then Menu appears on FL-display.
  (2)Set parameters described below.
             "ON LINE"---Use this setting when using the POA-3012CI connected in a network.
             "MASTER TRIGGER" or "POWER BUTTON"--- Use this setting when not using the POA-3012CI connected in a network.
               This setting is reducing the power consumption in the standby mode.




                                                            -3-
Protocol specification
The following three data forms are defined.
          COMMAND :      The message sent to a system(POA-3012CI) from a controller(Touch Panel etc.)
                         A command to a system is given from a controller.
          EVENT        : The message sent to a controller (Touch Panel etc.) from a system (POA-3012CI)
                         The result is sent, when a system is operated directly and a state changes.
                         *The form of EVENT presupposes that it is the same as that of COMMAND.
                         **Refer to the following table for the contents of COMMAND and EVENT.
          RESPONSE :     The message sent to a controller (Touch Panel etc.) from a system (POA-3012CI)
                         if the `request command' (COMMAND+?+CR(0x0D)) has came from a controller.
                         The RESPONSE should be sent within 200ms of receiving the COMMAND.
                         *The form of RESPONSE presupposes that it is the same as that of EVENT.

Basic specification: The command by ASCII CODE, parameter expression
       *ASCII CODE which can be used is from 0x20 to 0x7F: the alphabet and the number of 0-9, and space (0x20), some signs,
                                                                  AND carriage return (0x0D) --- It is used only as a pause sign.

Command structure: COMMAND + CHANNEL + PARAMETER + CR (0x0D)
        COMMAND: ASCII CODE of 2 characters
                   Ex.         SI : Select Input source
                               SV : Volume setting
                               SO : Operation mode Setting
                               SF : Low cut filter Mode Setting
                               PW : system Power setting
        CHANNEL : ASCII CODE of 2 characters (00 to 12)
                  Ex.         09 : channel number
                               00 : for system setting
        PARAMETER : ASCII CODE ( up to 25 characters)
                   Ex.         BUSL : function name
                               BRIDGED: operation mode name
                       *Special Parameter--- ? : for request command

                                                              -4-
The example of a command           *  is the meaning of 0x0D.
      SI09BUSL : Select Input source "BUS L" at channel 9.
      SO06BRIDGED : Set Operation Mode to bridged mode at channel 5 & 6.
      SV02UP : Master Volume UP at channel 2.
      PW00ON : system PoWer ON
      PW00STANDBY : system PoWer STANDBY
      SI04? : Request command for now playing input source at channel 4 >> Return RESPONSE `SI04****'




                                                           -5-
Others
A) COMMAND is receivable also during transmission of EVENT.
B) The RESPONSE should be sent as opposed to the request command by all the commands with which an EVENT exists , not need to
   the another request commands(ex. SV command).
C) The PARAMETER (with COMMAND and RESPONSE, EVENT) of minimum level of MASTER VOLUME defines "99".

D) If the MASTER VOLUME & CHANNEL VOLUME set with 0.5dB step, the PARAMETER (with COMMAND and RESPONSE, EVENT) defines three
   ASCII characters as bellows.
       Ex.   MASTER VOLUME = 0dB     :     SV90
                              -0.5dB :     SV895
                              -1.0dB :     SV89
                                |            |
                             -89.5dB :     SV005
                             -90.0dB :     SV00
                             ---.-dB :     SV99
       * At the **.0dB step, only uses two ASCII characters as PARAMETER, same as usual.
K) Four seconds later, please transmit the next COMMAND after transmitting a power on COMMAND PW00ON .




                                                             -6-
COMMAND and PARAMETER list
  COMMAND        CHANNEL     PARAMETER                      function                                  example
 PW         00             ON            POWER ON/STANDBY change                         PW00ON
                           STANDBY                                                       PW00STANDBY
                           ?             Return PW Status                                PW00?
 SV          *01-12        UP            CHANNEL VOLUME UP/DOWN , direct change to **dB SV01UP
                           DOWN                                                          SV01DOWN
                           **            **:00 to 99 by ASCII , 90=0dB, 99=---(MIN)      SV0180
                           ?             Return channel volume Status                    SV01?
 SO          02-12(EVEN)   NOR           Operation mode NORMAL/BRIDGED change            SO02NOR
                           BRI                                                           SO02BRI
                           ?             Return operation mode status                    SO02?
 SF          *01-12        OFF           Channel Low Cut Filter OFF/ON change            SF05OFF
                           ON                                                            SF05ON
                           ?             Return channel Low Cut Filter status            SF05?
 SI          *01-12        BUSL          Select input "BUS L"                            SI06BUSL
                           BUSR          BUS R                                           SI06BUSR
                           BUSM          BUS MONO(L+R)                                   SI06BUSM
                           AUX           AUX                                             SI06AUX
                           ?             Return channel Input status                     SI06?
 ST          02-12(EVEN)   CONT          constant                                        ST08CONT
                           TRIG          Trigger in                                      ST08TRIG
                           ASIG          Audio signal                                    ST08ASIG
                           OFF           Off                                             ST08OFF
                           ?             Return Zone Turn On status                      ST08?
             00            PBTN          Power button                                    ST00PBTN
                           TRIG          MASTER TRIGGER                                  ST00TRIG
                           ONLI          ON LINE                                         ST00ONLI
                           ?             Return Power ON status                          ST00?
   SV COMMAND : "*" parameter uses two or three ASCII characters. (see page6 D) section)
   *01-12 : The ZONE that "Normal mode" was selected, odd and even CHANNEL selectable. If the ZONE that "BRIDGED mode" was
     selected, only an even number CHANNEL selectable.




                                                          -7-
  COMMAND         CHANNEL     PARAMETER                      function                                    example
 SD          00             BRI           FL display's dimmer level change                 SD00BRI
                            DIM                                                            SD00DIM
                            DAR                                                            SD00DAR
                            OFF                                                            SD00OFF
                            ?             Return   dimmer status                           SD00?
 TI          02-12(EVEN)    ?             Return   channel trigger input                   TI12?
             00             ?             Return   master trigger inputs                   TI00?
 AI          02-12(EVEN)    ?             Return   channel audio signal input              AI02?
 PR          00             TR?           Return   system(Main transformer) over heat data PR00TR?
                            IN?           Return   system(Cabinet inside) over heat data   PR00IN?
                            TM?           Return   system total operation time             PR00TM?
             02-12(EVEN)    PR?           Return   channel protection data                 PR10PR?
                            OH?           Return   channel over heat data                  PR10OH?



Panel Lock
  COMMAND             PARAMETER                              function                                   example
 SY          PANEL LOCK ON                PANEL BUTTON CONTROL LOCK ON                     SYPANEL LOCK ON
             PANEL LOCK OFF               PANEL BUTTUM CONTROL LOCK OFF                    SYPANEL LOCK OFF
             PANEL LOCK ?                 Request SYPANEL LOCK Status                      SYPANEL LOCK ?




                                                             -8-
EVENT(or RESPONSE) and PARAMETER list
       EVENT        CHANNEL     PARAMETER                      function                                    example
  PW           00             ON            POWER ON/STANDBY change                        PWON
                              STANDBY                                                      PWSTANDBY
  SV           *01-12         **            CHANNEL VOLUME change , **:00 to 99 by ASCII   SV80

                                                   90 = 0dB(MAX)
                                                   00 = -90dB
                                                   99 = ---(MIN)
  SO           02-12(EVEN)    NOR           OPERATION MODE change                          SO02NOR
                              BRI                                                          SO02BRI
  SF           *01-12         OFF           Channel Low Cut Filter OFF/ON change           SF04OFF
                              ON                                                           SF04ON
  SI           *01-12         BUSL          Channel INPUT source change                    SI03BUSL
                              BUSR                                                         SI03BUSR
                              BUSM                                                         SI03BUSM
                              AUX                                                          SI03AUX
  ST           02-12(EVEN)    CONT          Zone turn on mode change                       ST06CONT
                              TRIG                                                         ST06TRIG
                              ASIG                                                         ST06ASIG
                              OFF                                                          ST06OFF
               00             PBTN          Power configuration change                     ST00PBTN
                              TRIG                                                         ST00TRIG
                              ONLI                                                         ST00ONLI
  SD           00             BRI           Dimmer level change                            SD00BRI
               00             DIM                                                          SD00DIM
               00             DAR                                                          SD00DAR
               00             OFF                                                          SD00OFF
  TI           02-12(EVEN)    YES           Zone trigger input YES/NO change               TI12YES
                              NO                                                           TI12NO
               00             YES           Master trigger input YES/NO change             TI00YES
                              NO                                                           TI00NO
  AI           02-12(EVEN)    YES           channel audio signal input YES/NO change       AI02YES
                              NO                                                           AI02NO
                                                             -9-
     EVENT        CHANNEL      PARAMETER                       function                                example
PR           00             TROHWARN         MAIN TRANSFORMER OVER HEAT WARNING           PR00TROHWARN
                            TROHNONE         MAIN TRANSFORMER OVER HEAT NONE              PR00TROHNONE
                            INOHWARN         CABINET INSIDE OVER HEAT WARNING             PR00INOHWARN
                            INOHNONE         CABINET INSIDE OVER HEAT NONE                PR00INOHNONE
                                             MAIN TRANSFORMER
                            TMOHTR01******   Over heat operation time (latest)            PR00TMOHTR01000130
                            TMOHTR02******   Over heat operation time (latest 1st ago)    PR00TMOHTR02000140
                                   |                               |                             |
                            TMOHTR20******   Over heat operation time (latest 19th ago)   PR00TMOHTR20000230
                                             ******:000000 to 999999 by ASCII
                                             , 000230 = 2hour30min
                                             CABINET INSIDE
                            TMOHIN01******   Over heat operation time (latest)            PR00TMOHIN01000130
                            TMOHIN02******   Over heat operation time (latest 1st ago)    PR00TMOHIN02000140
                                   |                               |                             |
                            TMOHIN20******   Over heat operation time (latest 19th ago)   PR00TMOHIN20000230
                                             ******:000000 to 999999 by ASCII
                                             , 000230 = 2hour30min
                            TM******         Total operation time                         PR00TM001120
                                             ******:000000 to 999999 by ASCII
                                             , 001120 = 11hour20min
             02-12(EVEN)    PRWARN           ZONE POWER MODULE PROTECTION WARNING         PR08PRWARN
                            PRNONE           ZONE POWER MODULE PROTECTION NONE            PR08PRNONE
                            OHWARN           ZONE POWER MODULE OVER HEAT WARNING          PR08OHWARN
                            OHNONE           ZONE POWER MODULE OVER HEAT NONE             PR08OHNONE
                            PR******         Protection operation time                    PR04PR000130
                                             ******:000000 to 999999 by ASCII
                                             , 000230 = 2hour30min
                            OH01******       Over heat operation time (latest)            PR04OH01000130
                            OH02******       Over heat operation time (latest 1st ago)    PR04OH02000140
                                   |                               |                             |
                            OH20******       Over heat operation time (latest 19th ago)   PR04OH20000230
                                             ******:000000 to 999999 by ASCII
                                             , 000230 = 2hour30min

                                                            - 10 -
Panel Lock
   EVENT               PARAMETER                     function              example
 SY          PANEL LOCK ON         PANEL BUTTON CONTROL LOCK ON    SYPANEL LOCK ON
             PANEL LOCK OFF        PANEL BUTTUM CONTROL LOCK OFF   SYPANEL LOCK OFF




                                                 - 11 -