Service Manuals, User Guides, Schematic Diagrams or docs for : Daewoo DSB DSB-077 & 097 & 127LH & 187LH & 247LH DSB-077 & 097 & 127LH & 187LH & 247LH v3

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
DSB-077 & 097 & 127LH & 187LH & 247LH v3


>> Download DSB-077 & 097 & 127LH & 187LH & 247LH v3 documenatation <<

Text preview - extract from the document
     INSTALLATION(07 09 12 18 TYPE)
              Discharge the air procedure
         Connect assembly pipe to the appropriate valve on the indoor
         unit and outdoor unit and tighten the flare nut(as fig.1).
         Screw down the nut of connecting pipr with wrench(the torque as
         follow diagram )

     NOTICE                                                                                   (Fig.1)
      1.The number of bent position of the pipe in the indoor unit should not exceed 10.
      2.The number of bent position of the pipe in the indoor unit and the outdoor unit should not
      exceed 15.
      3. The radius of bent position should more than 10cm.

                     PIPE                    DIAMETER OF PIPE                        TORQUE(N m)
                  Liquid pipe                   6.35mm ( 1/4   )                           13.7---17.6
                  Gas pipe                      9.52mm ( 3/8   )                           34.3---41.2
                  Gas pipe                      12.7mm ( 1/2   )                           49.0---56.4


         Discharge the air of the units:
         (lt can use vacuum pump, too.)
                                                                                           liquid connecting pipe
         Take off screw cap for closing valve and gas
                                                                    liquid closing valve
         charging hole;                                                                                  Allen wrench
                                                                   gas closing
         Open the closing valve with Allen wrench(turn             valve                                 gas conne-
                                                                                                         cting pipe
         90 clockwise), then push the gas charging hole                                                    Screw cap
         about 10 seconds, (When the gas like the fog
         appears, indicating the air of unit is discharge at all.)                      gas charging hole
                                                                                       Screw cap
         Screw down the screw cap of gas charging hole.
         Proceed leak test with leak detector or soap water.




21
INSTALLATION(24 TYPE)
    OUTDOOR UNIT

 1       Wiring
                                                                                    The cable wire can be led from the back hole
          Outdoor unit                                                              of the piping hole or ejecting hole.
    1 Remove the self-tapping screws (2 pcs)                                        Please utilize outdoor pipe support when
    onthe maintenance board and take out the                                         the cable wire is led from the backside.
    maintenance board.



                                  Terminal board

                                   Fix the cable wire
                                   with anchor cable


Maintenance
board                                                                           Outdoor pipe support
                                                                                (Outdoor pipe support is not required
                    Piping cover                                                when leading the cable wire from other places).
2 Loosen the self-tapping screws (2 pcs) on
the fixing clip to loosen the fixing clip.

 3 Loosen the fixing screw of the wire terminal                               4 Tighten the self-tapping screw on the fixing clip.
 board, pass the power wire and signal wire                                  5 Install the maintenance board. After the pipes
 through the fixing clip. Then firmly fix the                                and cable wire are installed, please seal the sponge
 power wire and signal wire on the terminal board                            block as per drawing indication.
 with the fixing screw. (Ground wire must be
 connected firmly.)




                                      Back wiring


Maintenance                          Right wiring
board
                                                                                    Sponge
                 Piping cover Ejecting hole                                                                                                          Piping cover

                                                            Connect diagram
                                  L N2                                                        L N23
                                                                                                                                               Connecting
                                                             Indoor unit terminal                                                              joint


                                                        Connecting cable
                                                                                                                                       Brown
                                                                                                      Yellow/Green




                             White
                                      Blue




                                                                                         White                        Red     Yellow
                              White          Yellow/Green                                                            White
                                                                                              Blue                                 Blue
                          L1 L2
                           L  2    L3 N                                             L1
                                                                                     L
                                                                                         L2
                                                                                          2   L3 N                     234        5
                                                                                                                                  R1 R2
                                                                                                                                       6
                                                                                                                      



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo