Text preview - extract from the document
GOODMANS 1418 R                                                                                                                                       1
                                General Information                                                          MAIN B + (+103V) ADJUSTMENT
                                                                                                             1. Receive RETMA pattern signal.
                                                                                                                                                                     VCO/AFT ADJUSTMENT
                                                                                                                                                                                                                                          Waveforms
                                                                                                             2. Set the picture level to NORMAL mode.                1. APPARATUS CONNECTION &
                                                                                                             3. Connect DC voltage meter to the TP7 and                 PRESETTING CONNECTION
                                      Also Covers                                                               adjust VR801 for +103V DC.                           1. Connect H-out of LSW-480 to X-axis of the
                                     DTC-14B1 VUP                                                                                                                       oscilloscope and V-out of LSW-480 to Y-axis
                                                                                                                                                                        of the oscilloscope.
                                     Daewoo CP-325                                                                                                                   2. Connect the sweep signal output to TP1.
                                                                                                                                                                     3. Set ATTENUATOR of LSW-480 to 30dB.
                                                                                                                                                                     4. Supply 16.5V D.C. voltage (B+) to TP4.
                                                                                                                                                                     5. Supply 4-5V D.C. voltage to TP5:VCO.
                                                                                                                                                                     6. Supply 7-8V D.C. voltage to TP5:AFT.
                                              Matrix
 Item                                                                                                                                                                PRESET
                                                                                                                                                                     1) Oscilloscope Scaling
 CRT Purity Adjustments - See Note
                                                                                                                                                                        D.C level.
                                                                                                                                                                     b) Set the horizontal time display to X-Y c) Put
                                                                                                                                                                        the horizontal axis (X) to 1V/div. and the
                                                                                                                                                                        vertical axis (Y) to 2V/div.
    X-Ray Precautions                                                                                                                                                2) LSW-480 MARKER FREQ. SETTING.
  X-RAY RADIATION PRECAUTION                            3. Rotate the SUB-BRIGHTNESS VR (VR513)
  1 Excessive high voltage can produce poten-              gradually CCW until the last beam disappears             Fig. 1                      Fig. 2                      fp(n+1) fs       fc      fp-2      fp     fs(n-1)
     tially hazardous X-RAY RADIATION. To avoid            on the screen.                                                                                            B/G    31.9    33.4     34.5    36.9      38.9   40.4
     such hazards, the high voltage must not                                                                 Fig. 1                                                  P-I    31.9    33.5     35.07   37.5      39.5   41
     exceed the specified limit. The nominal value      COLOUR AMPLITUDE AND PHASE                           Centre Convergence by Convergence Magnets
     of the high voltage of this receiver is 25.5kv     ADJUSTMENT
     (14": 23.5kv) at max beam current. The high                                                             Fig. 2
     voltage must not, under any circumstances,         1. Receive a PAL/DEM Signal (Philips Model           Circumference Convergence by DEF. Yoke
     exceed 27.5kv (14": 25.0kv). Each time a              PM5518)
     receiver requires servicing, the high voltage      2. Connect the probe of an oscilloscope to R203
     should be checked following the HIGH                  (TP6:B-Y output)
     VOLTAGE CHECK procedure. It is recom-              3. Adjust L510 and VR516 in order to make the
     mended the reading of the high voltage be             waveform fine on the screen like Fig. 1.
     recorded as a part of the service records. It is
     important to use an accurate and reliable high
     voltage metre.
  2. The only source of X-RAY RADIATION in this
     TV receiver is the picture tube. For continued                                                                                                                  Connection for PIF Adjustments
     X-RAY RADIATION protection, the replace-                                                                Fig. 3 Adjustment of magnets
     ment tube must be exactly the same type tube                                                                                                                    II. ADJUSTMENT OF VCO (B/G, I)
     as specified in the parts list.                                                                                                                                 1. Connect the test point of LSW-480 to TP2.
                                                                                                                                                                     2. Adjust L109 (ACO COIL) so that the P marker
            Adjustments                                 Fig. 1                                                                                                           point is located on the reference level.
  SCREEN & WHITE BALANCE ADJUSTMENT                     VERTICAL HEIGHT ADJUSTMENT                                                                                   Ill. ADJUSTMENT OF AFT B/G, I)
  1.This adjustment is to be made only after            1. Receive RETMA pattern signal                                                                              1. Connet the test point of LSW-480 to TP3
     warming up at least 15 minutes.                    2. Set the BRIGHTNESS control and CON-                                                                       2. Adjust L108 (AFT COIL) so that the P marker
  2. Receive B,W pattern signal                            TRAST control to Max., and the COLOR              Fig. 4 Rubber wedge location                                point is located on the reference level.
  3. Set the RGB Bias VR (RJ04, RJ13, RJ24) to             control to centre.
     MINIMUM.                                           3. Adjust VR306 for the optimum vertical height                                                              VCO Waveform
  4. Set the G, B Drive VR (RJ1 4, RJ22) to                and over scanning.
     CENTER.
  5. Set the CONTRAST, BRIGHTNESS,                      VERTICAL CENTRE ADJUSTMENT
     COLOUR control to MIN, and Sub-brightness          1. Receive RETMA pattern signal.
     control to CENTER.                                 2. Adjust VR317 so that the vertical center of the
  6. Connect a short P501 to GND.                          picture may be coincident with the mechanical                                                             AFT Waveform
  7. Rotate the SCREEN control to clockwise or             center of CRT.
     CCW so as to obtain dim horizontal line of
     one color in R, G and B.                           HORIZONTAL CENTRE ADJUSTMENT                         Fig. 5 Picture tube neck component
  8. Rotate the R, G and B Bias VR of the other         1 Receive RETMA pattern signal.
     color which did not appear on the screen                                                                  Tube Size Table
                                                        2. Adjust VR426 so that the horizontal centre of
     clockwise, until a dim white line is obtained.        the picture may be coincident with the             NO.     LOC.                    14"                                      20"
  9. Rotate the Screen control gradually anti-             mechanical centre of CRT.
     clockwise until the last horizontal line                                                                 1       CRT        ORION              POLKOLOR         ORION         SAMSUNG           POLKOLOR
     disappears on the screen.                          FOCUS VOLTAGE ADJUSTMENT                                                 A34JLL90X          A34EFU13X       A4JLL90X       A4BECR11XI6       A4BEEV33X01
  10.Remove the short P501 and set the CON-             1. Receive RETMA pattern signal.                      2       CRT        ISM--01            CTV3240--0501   ISM--03        CTV3240--0501            
     TRAST, BRIGHTNESS, COLOR control to                2. Adjust the FOCUS VOLUME on the FBT and                     SOCKET
     MAX.                                                  make the picture on the screen be finest.          3       D/COIL     DC--1450                           DC--2050                            
  11.Set the G, B Drive VR to obtain the best                                                                 4       T401       DCF--2077D         FSA24006S       DCF-2217J      FSA--17013M       FSA26012M
     white uniformity on the screen.                    RF AGC ADJUSTMENT                                                                           1142.50258
  12.Rotate the CONTRAST, BRIGHTNESS,                   1. Receive PAL COLOR BAR signal in the VHF            5       L404       L--125             1--76           L--102         L--62             L--76
     COLOR controls until a dim raster is obtained
     and touch-up adjustment of RGB Bias VR to
                                                           high band where the strength of signal can be      6       R413       1W 4.7ohm(F)       1W 0.33ohm(F)   1W 6.2ohm(F)   1W 2.7ohm(F)      1W 2ohm(F)                 Control
                                                           60-65 dB.                                          7       R416       1/4W 390K          1/4W 330K       1/4W 240K      1/4W 270K         1/4W 240K
     obtain the best white uniformity on the screen.    2. Set the CONTRAST control to Max., the
                                                           BRIGHTNESS control to provide adequate
                                                                                                              8
                                                                                                              9
                                                                                                                      R417
                                                                                                                      R530
                                                                                                                                 1/4W 390K
                                                                                                                                 1/6W 4.3K
                                                                                                                                                    1/4w 330K
                                                                                                                                                        
                                                                                                                                                                    1/4W 240K
                                                                                                                                                                    1/5W 22K
                                                                                                                                                                                   1/4W 270K
                                                                                                                                                                                        
                                                                                                                                                                                                     1/4W 240K
                                                                                                                                                                                                         
                                                                                                                                                                                                                                Diagram
  SUB-BRIGHTNESS ADJUSTMENT                                black and grey scales.                             10      R540       1/6W 1K                            1/5W 56K                             
  1 White balance adjustment must proceed this          3. Maintain the fine tuning on the screen, and        11      C406       1.6KV 6000P        1.6KV 6000P     1.6KV 6900P    1.6KV 8200P       1.6KV 7500P
     procedure.                                            adjust VR130 (AGC DELAY CONTROL VR.)               12      C421       200V 0.47u         200W 0.51u      200V 0.47u     200V 0.51u        200V 0.51u
  2. Set the CONTRAST, BRIGHTNESS, COLOR                   in order that it may be located on the position    13      C414        --                2KV 470P        --              2KV 660P         2KV 470P
     control to MIN.                                       which the picture noise disappear on the
                                                           image.




                                     X-Ray Precautions / Adjustments / Tube Size Table / Waveforms / Control Diagram / Troubleshooting / Troubleshooting Cont'd
                                                            CRT Diagram / Remote Control Diagram / Main Diagram / Main Diagram Cont'd
GOODMANS 1418 R                                                  2
                     1. No Raster                                3. Auto Search Trouble (Channel Skip)                           5. No Colour
  Troubleshooting
      Guides




                     2. No Picture (Raster OK)

                                                                                              4. No Vertical Scanning           6. No Specific Colour
                                                                                              (One Horizontal Line On Screen)




             X-Ray Precautions / Adjustments / Tube Size Table / Waveforms / Control Diagram / Troubleshooting / Troubleshooting Cont'd
                                    CRT Diagram / Remote Control Diagram / Main Diagram / Main Diagram Cont'd
GOODMANS 1418 R                                                                             3
 Troubleshooting Guides Cont'd                                 9. No On-Screen Display
                                                                                                                                  CRT Diagram
 7. No Sound (Picture OK)




                                                               10. Remote Control Trouble
                                                               (Local Control OK)



 8. No External AV
                                                                                                           Remote
                                                                                                           Control
                                                                                                           Diagram




                            X-Ray Precautions / Adjustments / Tube Size Table / Waveforms / Control Diagram / Troubleshooting / Troubleshooting Cont'd
                                                   CRT Diagram / Remote Control Diagram / Main Diagram / Main Diagram Cont'd
GOODMANS 1418 R                                                 4
   Main Diagram




            X-Ray Precautions / Adjustments / Tube Size Table / Waveforms / Control Diagram / Troubleshooting / Troubleshooting Cont'd
                                   CRT Diagram / Remote Control Diagram / Main Diagram / Main Diagram Cont'd
GOODMANS 1418 R                                                 5
       Main Diagram Cont'd




          X-Ray Precautions / Adjustments / Tube Size Table / Waveforms / Control Diagram / Troubleshooting / Troubleshooting Cont'd
                                 CRT Diagram / Remote Control Diagram / Main Diagram / Main Diagram Cont'd