         D-160 Owner's Manual Supplement (V2.10)
The functions explained here are additions to the main manual because of our version-up
(V2.10) of the D-160 software. Please read this manual together with the main manual
before operating the D-160.


1. Large capacity hard disks can now be used.
  It is now possible to use E-IDE hard disks with a recording capacity up to approximately
  30GB (FS=44.1kHz) as the D-160's recording media (current drive/backup drive).
  Please refer to "List of hard disks checked for operation" to make sure any product you
  are about to use will operate correctly.
  : When formatting a large capacity hard disk, the time required to format will be in
  relation to disk size. As a general estimate, it requires about 15 minutes to format 1GB and
  thus, as an example, it will take about 7 hours for a 30GB hard disk.


                            
            Maker                Model                          Disk Capacity

                              Fireball CX              6.4GB, 10.2GB, 13.0GB, 20.4GB
          Quantum
                              Fireball CR              4.3GB, 6.4GB, 8.4GB, 13.0GB




2. In the BAR/BEAT/CLK (bar/beat/clock) time base, the offset figure of the BAR
   that indicates the head of the disk can now be edited.
  Although [Time Base] is explained in [Before Operating] the main D-160 owners manual,
  the unit to indicate the present traveling position, MTC (MIDI time code) or BAR/BEAT/
  CLK (bar/beat/clock) is now also employed in addition to ABS (absolute time).
  Because of this, the figure indicating the present disk position will be different depending
  on the selected time base. When the D-160 is in the initial setup state and the MTC offset
  display at [MTC 00h 59m 57s 00f] for the disk in the head position (ABS 00m 00s 00f) or,
  at BAR/BEAT/CLK, it will display [-002bar 1 beat 00clk].
  Before version-up V2.10, this offset figure could be changed only for MTC, and the BAR/
  BEAT/CLK offset figure was fixed to [-002bar 1beat 00clk].
  But, with V2.10, the BAR offset figure in BAR/BEAT/CLK can now be changed to any
  figure within the -002 ~ -009 range.
  In the initial setup state of the D-160, [-002bar 1beat 00clk] will always be displayed and
  the bar offset figure will be [-002bar].
  To setup the offset figure of this BAR/BEAT/CLK display, execute it in the SETUP mode of
  the D-160, the same as the setup of the MTC offset figure. Please read the reverse side
  operating procedures. For setup of the MTC offset, refer to the explanations in the SETUP
  mode of the main owners manual.
                                                                 Setup procedures for BAR/BEAT/CLK offset
      : Offset setups can be executed for each program. The setup content will be
      maintained even though power is switched off.


1. First select the program to which offset is to be setup.                                                                                       4. Rotate the JOG dial counter-clockwise.
   The example below is the display as a result of selecting                                                                                         The offset figure of the current set bar will be
   program 1.                                                                                                                                        displayed. If it is in the initial state, [-002bar Offset?]
                                                                                                                                                     will be displayed as shown below.
                                                                                               ABS


              OL                                                                                                                                                                                                                                              SETUP
               0
               3
               6
               9                                                                                          44.1kHz
              12                                                                                                                                                      OL
              18                                                                                                                                                       0
                                                                                                                                                                       3                                                                                              SIGNATURE
              24
              30                                                                                                                                                       6
              42                                                                                                                                                       9                                                                                         44.1kHz
                                                                                                                                                                      12
                                                                                                                                                                      18
                   1   2   3    4    5       6       7   8   9   10   11   12   13   14   15    16                                                                    24
                                                                                                                                                                      30
                                                                                                                                                                      42


                                                                                                                                                                            1   2   3   4   5   6   7   8   9       10    11    12    13    14    15    16




                                                                                                                                                                                                                                           Blink
2. After switching to the SETUP display by pressing the
   DISP SEL key, press the EXECUTE/YES key.
   If the DISP SEL key is pressed twice against the above
                                                                                                                                                                       OL
                                                                                                                                                                        0
                                                                                                                                                                        3
                                                                                                                                                                        6
                                                                                                                                                                        9                                                                                         44.1kHz
                                                                                                                                                                       12
                                                                                                                                                                       18



   ABS display, it will change to the SETUP display and if
                                                                                                                                                                       24
                                                                                                                                                                       30
                                                                                                                                                                       42


                                                                                                                                                                            1   2   3   4   5   6   7   8   9       10    11    12    13    14    15    16


   the EXECUTE/YES key is pressed, it will change to the
   [Drive Sel ? (current drive setup)] menu as shown
                                                                                                                                                  5. Press the EXECUTE/YES key.
   below when in the initial setup state.
                                                                                                                         Blink                       The number [2] in -002bar will blink and the bar
                                                                                                                                                     offset figure can now be edited.
                                                                                                                              SETUP
       DISP SEL
                               OL
                                0
                                3
                                                                                                                                                                                Blink
                                6
                                9                                                                                                44.1kHz
                               12
                               18
                               24
                               30
                               42
                                                                                                                                                         EXECUTE
                                     1       2       3   4   5   6    7    8    9    10   11    12   13     14      15   16
                                                                                                                                                           / YES
                                                                                                                                                                       OL
                                                                                                                                                                        0
                                                                                                                                                                        3
                                                                                                                                                                        6
                                                                                                                                                                        9                                                                                         44.1kHz
                                                                                                                                                                       12
                                                                                                                                                                       18
                                                                                                                                                                       24
                                                                                                                                                                       30
                                                                                                                                                                       42


                                                                                                                                                                            1   2   3   4   5   6   7   8       9    10    11    12    13    14    15    16


       EXECUTE                                                                                                                SETUP

         / YES                 OL
                                0
                                3
                                6
                                9                                                                                                44.1kHz
                               12
                               18
                               24
                               30
                               42


                                     1       2       3   4   5   6    7    8    9    10   11   12    13     14      15   16
                                                                                                                                                  6. Rotate the JOG dial to input the desired offset figure,
                                                                                                                                                     then press the EXECUTE/YES key.
                                                                                Blink
                                                                                                                                                     Any offset figure within a 2~9 range can be input
                                                                                                                                                     (the example below is the result of inputting of 5 for
3. Rotate the JOG dial to show [Signature Set?] in the                                                                                               the bar figure). After this, press the EXECUTE/YES
   display and press the EXECUTE/YES key.                                                                                                            key and it will be set to the input offset figure and the
   The current set bar will be displayed and if it is in the                                                                                         display will change to the [Signature Set?] menu.
   initial setup state, the first bar will be 4/4.
                                                                                               Blink
                                                                                                                                                                       OL
                                                                                                                                                                        0
                                                                                                                                                                        3
                                                                                                                                                                        6
                                                                                                                                                                        9                                                                                        44.1kHz
                                                                                                                                                                       12
                                                                                                                                                                       18
                                                                                                                              SETUP                                    24
                                                                                                                                                                       30
                                                                                                                                                                       42

                                OL
                                 0                                                                                                                                          1   2   3   4   5   6   7   8   9       10    11    12    13    14    15    16
                                 3
                                 6
                                 9                                                                                               44.1kHz
                                12
                                18
                                24
                                30
                                42


                                         1       2   3   4   5   6    7    8    9    10   11    12   13     14      15   16


                                                                                                                                                       EXECUTE                                                                                                SETUP

                                                                                                                                                         / YES
                                                                                                                                                                       OL
                                                                                                                                                                        0
                                                                                                                                                                        3
                                                                                                                                                                        6
                                                                                                                                                                        9                                                                                        44.1kHz
                                                                                                                                                                       12
                                                                                                                                                                       18
                                                                                                                                                                       24

       EXECUTE                                                                                                                SETUP                                    30
                                                                                                                                                                       42


         / YES                 OL
                                0
                                                                                                                                                                            1   2   3   4   5   6   7   8   9       10    11    12    13    14    15    16

                                3                                                                                                     SIGNATURE
                                6
                                9                                                                                                44.1kHz
                               12
                               18
                               24
                               30
                               42                                                                                                                                                                                               Blink
                                     1       2       3   4   5   6    7    8    9    10   11   12    13    14       15   16




                                                                                                                                                  7. Exit from the SETUP mode by pressing the EXIT/NO