Service Manuals, User Guides, Schematic Diagrams or docs for : Hitachi Monitor Hitachi_55HDT51M_42HDT51M_[SM]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Hitachi_55HDT51M_42HDT51M_[SM]


>> Download Hitachi_55HDT51M_42HDT51M_[SM] documenatation <<

Text preview - extract from the document
                                                                                         PA                             No. 0187
                                                                                              42HDT51M:                         PT5-G Chassis
                                                                                              55HDT51M:                        PW1-H Chassis
                                                                                                AVC75:                         AVC5-U Chassis
         SERVICE MANUAL
                      PT5-G/PW1-H
NTSC                                                                                                   R/C: CLU-3841WL
                     AV C 5 - U C h a s s i s
                                        TO GO TO A CHAPTER, CLICK ON ITS HEADING BELOW
                                                                     CONTENTS
                     SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
                     PRODUCT SAFETY NOTICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
                     SERVICING PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
                     AGENCY REGULATORY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
                     ACKNOWLEDGMENTS AND TRADEMARKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
                     INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
                     SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
                     BASIC SETUP & OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
                     ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
                     TROUBLESHOOTING FLOWCHARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
                     BLOCK DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
                     CONNECTION DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
                     FINAL WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
                     EXPLODED VIEW (AVC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
                     WAVEEFORMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
                     DC VOLTAGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..70
                     CIRCUIT SCHEMATIC DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
                     PRINTED CIRCUIT BOARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
                     EXPLODED VIEW (PDP MONITOR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107 Updated 5/23/05
                     PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109 Updated 8/11/05
                     QUICK REFERENCE PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130

     CAUTION:        These servicing instructions are for use by qualified service personnel only. To reduce the risk of
                     electric shock do not perform any servicing other than that contained in the operating instructions
                     unless you are qualified to do so. Before servicing this chassis, it is important that the service
                     technician read the "IMPORTANT SAFETY INSTRUCTIONS" in this service manual.
                                                       SAFETY NOTICE
                                   USE ISOLATION TRANSFORMER WHEN SERVICING
     Components having special safety characteristics are identified by a ! on the schematics and on the parts list in this
     Service Data and its supplements and bulletins. Before servicing the chassis, it is important that the service technician
     read and follow the "Important Safety Instructions" in this Service Manual.




 SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT

                                PLASMA DISPLAY PANEL
JUNE 2004                                                                          HHEA-MANUFACTURING DIVISION
 Version 0187.2
                                                                                                                           PT5-G/PW1-H

SAFETY PRECAUTIONS
NOTICE: Comply with all cautions and safety-related notes                   Leakage Current Hot Check
located on or inside the cover case and on the chassis or plasma              This check must be done considering the AVC or the PDP
module.                                                                       monitor as one instrument each.
WARNING: Since the chassis of the AVC unit and Plasma Panel                   With any of the instruments completely reassembled (being
unit is connected to both sides of the AC power supply during                 the instrument either the AVC center or the PDP monitor), plug
operation, whenever the receiver is plugged in, service should                the AC line cord directly into a 120V AC outlet. (Do not use an
not be attempted by anyone unfamiliar with the precautions                    isolation transformer during this test.) Use a leakage current
necessary when working on this type of receiver.                              tester or a metering system that complies with the American
                                                                              National Standards Institute (ANSI) C101.0 Leakage Current
1. When service is required, an isolation transformer should be               for Appliances. In the case of the PDP monitor set the AC
   inserted between power line and the receiver before any                    switch first in the ON position and then in the OFF position,
   service is performed on a "HOT" chassis receiver.                          measure from across Line 1 and Line 2 of the three plug
                                                                              prongs, do not connect with the third prong, which is physical
2. When replacing a chassis in the receiver, all the protective               ground, to all exposed metal parts of the instrument
   devices must be put back in place, such as barriers, non-                  (antennas, handle bracket, metal cabinet, screw heads,
   metallic knobs, insulating cover-shields, and isolation                    metallic overlays, control shafts, etc.), especially any exposed
   resistors, capacitors, etc.                                                metal parts that offer an electrical return path to the chassis.
                                                                              Any current measured must not exceed 0.5 MIU. Reverse the
3. When service is required, observe the original lead dress.                 instrument power cord plug in the outlet and repeat test.
                                                                            AC LEAKAGE TEST
4. Always use manufacturer's replacement components. Critical
   components as indicated on the circuit diagram should not be                                                        (READING
   replaced by another manufacturer's. Furthermore, where a                                                            SHOULD NOT
   short circuit has occurred, replace those components that                                                   LEAKAGE BE ABOVE 0.5MIU)
                                                                                                               CURRENT
   indicate evidence of over heating.                                                DEVICE                    TESTER
                                                                                     UNDER
5. Before returning a serviced receiver to the customer, the                         TEST
   service technician must thoroughly test the unit to be certain                                 TEST ALL
                                                                                                  EXPOSED
   that it is completely safe to operate without danger of electrical                             METAL SURFACES
   shock, and be sure that no protective device built into the                                                                    EARTH
                                                                                         3-WIRE CORD
   receiver by the manufacturer has become defective, or                                                                          GROUND
   inadvertently defeated during servicing.                                          ALSO TEST WITH PLUG
                                                                                     REVERSED
Therefore, the following checks should be performed for the                          (USING AC ADAPTER
                                                                                     PLUS AS REQUIRED)
continued protection of the customer and service technician.

Leakage Current Cold Check                                                  ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED
  With the AC plug removed from the 120V AC 60Hz source,                    ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD
  place a jumper across Line 1 and Line 2 of the three plug                 AND MUST BE CORRECTED BEFORE RETURNING THE
  prongs, do not connect with the third prong, which is physical            RECEIVER TO THE CUSTOMER.
  ground.
  Using an insulation tester (DC500V), connect one of its leads
  to the AC plug jumper and touch with the other lead each
  exposed metal part (antennas, screwheads, metal overlays,
  control shafts, etc.), particularly any exposed metal part
  having a return path to the chassis should have a resistor
  reading over 4M. Any resistance value below this range
  indicates an abnormality which requires corrective action. An
  exposed metal part not having a return path to the chassis will
  indicate an open circuit.




                                                                        2
    TABLE OF CONTENTS
                                                                                                                              PT5-G/PW1-H

PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in HITACHI television                     PDP Module Handling
receivers have special safety-related characteristics. These are
often not evident from visual inspection nor can the protection                When there is need to replace a broken PDP module which is the
afforded by them necessarily be obtained by using replacement                  displaying device from the Plasma monitor unit, consider the
components rated for higher voltage, wattage, etc. Replacement                 following:
parts which have these special safety characteristics are
identified in this Service Manual.                                             1. When carrying the PDP module, two persons should stand at
                                                                                  both shorter-edge sides of the glass-panel and transport it with
Electrical components having such features are identified with a                  their palms. Avoid touching the Flexible Printed Circuits or the
1 mark in the schematics and parts list in this Service Manual.
!                                                                                 chip tube on the corner of the glass-panel. Handle only by the
                                                                                  surface of the glass panel. In case of some PDP modules,
The use of a substitute replacement component which does not                      electrode repair is done by connecting between regular
have the same safety characteristics as the HITACHI-                              terminal with Cu tape and Cu wire. Please do not hook and/or
recommended replacement component, shown in the parts list in                     damage this repair line. If it is damaged, the module will not
this Service Manual, may create shock, fire, X-radiation, or other                function unless the glass-panel is exchanged with a new
hazards.                                                                          glass-panel.
                                                                               2. When carrying PDP module, watch surrounding objects, such
Product safety is continuously under review and new instructions                  as tables, and also do not carry it alone since it may be
are issued from time to time. For the latest information, always                  dangerous and it will be damaged due to excessive stress to
consult the current HITACHI Service Manual. A subscription to,                    the module (glass-panel).
or additional copies of HITACHI Service Manuals may be                         3. Please do not stand the module with the edge of the glass-
obtained at a nominal charge from HITACHI Sales Corporation.                      panel on the table since this might result in damage to the
                                                                                  glass-panel and/or flexible printed circuits due to excessive
AVC75 - Audio Video Control Unit                                                  stress to the module (glass-panel).

1. Follow the general caution recommendations from "Safety                     WARNING
   precautions" section.                                                       Lead in solder used in this product is listed by the California
                                                                               Health and Welfare agency as a known reproductive toxicant
42HDT51M - Plasma Monitor Unit                                                 which may cause birth defects or other reproductive harm
55HDT51M - Plasma Monitor Unit                                                 (California Health and Safety Code, Section 25249.5).

1. Follow the general caution recommendations from "Safety                     When servicing or handling circuit boards and other components
   precautions" section.                                                       which contain lead in solder, avoid unprotected skin contact with
2. Since the Panel module and front filter are made of glass,                  solder. Also, when soldering make sure you are in a well
   sufficient care shall be taken when handling the broken                     ventilated area in order to avoid inhalation of any smoke or
   module and filter in order to avoid injury.                                 fumes released.
3. If necessary to replace Panel module, this work must be
   started after the panel module and the AC/DC Power supply                                         SAFETY NOTICE
   becomes sufficiently cool.                                                                 USE ISOLATION TRANSFORMER
4. Special care must be taken with the display area to avoid                                        WHEN SERVICING
   damaging its surface.
5. The Panel Module shall not be touched with bare hands to                    POWER SOURCE
   protect its surface from stains.
6. It is recommended to use clean soft gloves during the                       This plasma television and the AVC Center is designed to
   replacing work of the Panel module in order to protect, not                 operate on 120 Volts/60Hz, AC house current. Insert the power
   only the display area of the panel module but also the                      cord into a 120 Volts/60Hz outlet.
   serviceman.
7. The Chip Tube of the panel module (located upper left of the                NEVER CONNECT THE PLASMA AND THE AVC CENTER TO
   back of the panel module) and flexible cables connecting                    OTHER THAN THE SPECIFIED VOLTAGE OR TO DIRECT
   Panel glasses to the drive circuitry Printed Wiring Boards                  CURRENT AND TO 50HZ. TO PREVENT ELECTRIC SHOCK,
   (P.W.B.) are very weak, so sufficient care must be taken to                 DO NOT USE THE PLASMA TELEVISION'S (POLARIZED)
   prevent breaking or cutting any of these. If the Chip Tube                  PLUG WITH AN EXTENSION CORD, RECEPTACLE, OR THE
   breaks the panel module will never work, replacement for a                  OUTLETS UNLESS THE BLADES AND GROUND TERMINAL
   new plasma panel module will be needed.                                     CAN BE FULLY UNSERTED TO PREVENT BLADE
8. Signal, power supply P.W.B.'s and PDP driving circuits                      EXPOSURE.
   P.W.B.'s are assembled on the rear side of the PDP module,
   take special care with this fragile circuitry; particularly, Flexible
   Printed Circuits bonded to surrounding edges of the glass
   panel. They are not strong enough to withstand harsh outer
   mechanical forces. Avoid touching the flexible printed circuits
   by not only your hands, but also tools, chassis, or any other
   object. Extreme bending of the connectors must be avoided
   too. In case the flexible printed circuits are damaged, the
   corresponding addressed portions of the screen will not be lit
   and exchange of a glass panel will be required.

                                                                           3
    TABLE OF CONTENTS
                                                                                                                     PT5-G/PW1-H

                                             SERVICING PRECAUTIONS
CAUTION: Before servicing instruments covered by this                 Electrostatically Sensitive (ES) Devices
service data and its supplements and addenda, read and                Some semiconductor (solid state) devices can be damaged
follow the "Important Safety Instructions" on page 3 of this          easily by static electricity. Such components commonly are
publication.                                                          called Electrostatically Sensitive (ES) Devices. Examples of
NOTE: If unforeseen circumstances create conflict between             typical ES devices are integrated circuits and some field-
the following servicing precautions and any of the safety             effect transistors and semiconductor "chip" components. The
precautions on page 3 of this publication, always follow the          following techniques should be used to help reduce the
safety precautions. Remember: Safety First.                           incidence of component damage caused by static electricity.

General Servicing Guidelines                                          1. Immediately before handling any semiconductor
1. Always unplug the instrument AC power cord from the AC                component or semiconductor-equipped assembly, drain
   power source before:                                                  off any electrostatic charge on your body by touching a
   a. Removing or reinstalling any component, circuit                    known earth ground. Alternatively, obtain and wear a
      board, module, or any other instrument assembly.                   commercially available discharging wrist strap device,
                                                                         which should be removed for potential shock reasons
  b. Disconnecting or reconnecting any instrument                        prior to applying power to the unit under test.
     electrical plug or other electrical connection.
                                                                      2. After removing an electrical assembly equipped with ES
  c. Connecting a test substitute in parallel with an                    devices, place the assembly on a conductive surface
     electrolytic capacitor in the instrument.                           such as aluminum foil, to prevent electrostatic charge
                                                                         buildup or exposure of the assembly.
      CAUTION: A wrong part substitution or incorrect
               polarity installation of electrolytic                  3. Use only a grounded-tip soldering iron to solder or
               capacitors may result in an explosion                     desolder ES devices.
               hazard.
                                                                      4. Use only an anti-static type solder removal device. Some
2. Do not spray chemicals on or near this instrument or any              solder removal devices not classified as "anti-static" can
   of its assemblies.                                                    generate electrical charges sufficient to damage ES
                                                                         device.
3. Unless specified otherwise in these service data, clean
   electrical contacts by applying the following mixture to the       5. Do not use freon-propelled chemicals. These can
   contacts with a pipe cleaner, cotton-tipped stick or                  generate electrical charges sufficient to damage ES
   comparable nonabrasive applicator: 10% (by volume)                    devices.
   Acetone and 90% (by volume) isopropyl alcohol (90%-
   99% strength).                                                     6. Do not remove a replacement ES device from its
   CAUTION: This is a flammable mixture. Unless                          protective package until immediately before you are
                  specified otherwise in these service data,             ready to install it. (Most replacement ES devices are
                  lubrication of contacts is not required.               packaged with leads electrically shorted together by
                                                                         conductive foam, aluminum foil or comparable conductive
4. Do not defeat any plug/socket of voltage interlocks with              material.)
   which instruments covered by this service data might be
   equipped.                                                          7. Immediately before removing the protective material from
                                                                         the leads of a replacement ES device, touch the
5. Do not apply AC power to this instrument and/or any of its            protective material to the chassis or circuit assembly into
   electrical assemblies unless all solid-state device heat-             which the device will be installed.
   sinks are correctly installed.                                        CAUTION: Be sure no power is applied to the chassis or
                                                                                     circuit, and observe all other safety
6. Always connect the test instrument ground lead to the                             precautions.
   appropriate instrument chassis ground before connecting
   the test instrument positive lead. Always remove the test          8. Minimize bodily motions when handling unpackaged
   instrument ground lead last.                                          replacement ES devices. (Otherwise harmless motion
                                                                         such as the brushing together of your clothes fabric or the
7. Use with this instrument only the test fixtures specified in          lifting of your foot from a carpeted floor can generate
   this service data.                                                    static electricity sufficient to damage an ES device.)
   CAUTION: Do not connect the test fixture ground strap
                 to any heatsink in this instrument.




                                                                  4
TABLE OF CONTENTS
                                                                                                                       PT5-G/PW1-H

General Soldering Guidelines                                           Removal
1. Use a grounded-tip, low-wattage soldering iron and                  1. Desolder and straighten each IC lead in one operation by
   appropriate tip size and shape that will maintain tip                  gently prying up on the lead with the soldering iron tip as
   temperature within the range 500



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo