                                                File No. GENL-13
                                                Form A24-3315-0




Systems Reference Library




Custom Peatures for
IBM 1401, 1440, and 1460 Data Processing Systems

This manual contains brief descriptions of
some of the custom features available for the
IBM 1401, 1440, or 1460 Data Processing
Systems. Availability of these features can
be determined by requesting a price quota-
tion from IBM.
                                           CONTENTS


CUSTOM FEATURES FOR IBM 1401, 1440, AND 1460
DATA PROCESSING SYSTEMS -- SECTION 1              5

IBM l401 Custom Features.                         5

SECTION 2. . . . . . . .                         14

IBM l401, 1440, and 1460 Custom Features         14

IBM 1401, 1460 Custom Features                   14

IBM 1440 Custom Features                         16

IBM 1460 Custom Features                         16

IBM 1440, 1460 Custom Features.                  16

INDEX (IN RPQ NUMBER ORDER)                      18
PREFACE


Custom features are designed to meet special appli-
cation requirements beyond the capabilities of the
standard or special features available with the sys-
tem. These custom features are developed as a re-
sult of the submission of a Request for Price Quota-
tion (RPQ) through an IBM sales representative.
The number assigned to the RPQ when originally
submitted becomes a reference for future requests
for this function.
    This brochure lists, alphabetically, the RPQ's
applicable to the IBM 1401 alone (Section 1) and
those applicable to the IBM 1401 or the IBM 1440 or
the IBM 1460 (Section 2). An index is provided by
RPQ number at the end of the publication.
    In considering these custom features, give spe-
cial consideration to the prerequisites necessary for
the proper operation of the RPQ. For further de-
tails and advice on custom features, consul t your
IBM sales representative.




Copies of this and other IBM publications can be obtained through IBM Branch Offices.
Address comments concerning the content of this publication to IBM Product Publications, Endicott, New York   13764.
                                                                                     CUSTOM FEA TURES FOR
                                                         IBM 1401. 1440. and 1460 DATA PROCESSING SYSTEMS
                                                                                                 SECTION 1

IBM 1401 CUSTOM FEATURES                                    Branch End of Forms                               W03462
                                                            1401 Model A, B, C, D, E, or F
bdditional Index Registers                      M01912
l401 Model B, C, E, or F                                    This device makes available a branch instruction
                                                            that causes the 1401 to branch on a 1403 end-of-
This device permits three additional index registers        forms condition.
for the 1401. Addresses assigned to the new index
locations are:                                              Branch End of Forms, Second Printer               W04100
                                                            1401 Model A, B, C, D, E, or F
    location 4     storage 187-189      address 189
                                                            This device adds the circuitry to accept a branch on
    location 5     storage 192 -194     address 194         end-of-form im~truction for the second printer in a
                                                            dual 1403 system.
    location 6     storage 197-199      address 199
                                                            Prerequisite: W03462 on the 1401, and 815064 on
Normal tens-position tagging remains the same.              the 1924-43.
Index locations 4, 5 p and 6 are chosen by tagging
the units position with a word mark. The word mark          Branch End of Form                                    815064
must be placed after a normal tagging operation o           1924-43
The word Inark is automatically removed during the
indexing operation.                                         This feature provides for recognition of a branch
                                                            end-of-form instruction for the second printer in a
    location 4     tens position A -bit, no B-bit,          dual 1403 system.
                   units-position WM
                                                            Prerequisite: RPQ W04100 on the 1401.
     location 5    tens position B-bit, no A-bit,
                   units-position WM                        Branch on Inquiry-Special                             F93019
                                                            1401 Model C, D, E, F
     location 6    tens position A-bit, B-bit, units-
                   position WM                              This feature allows for a program-test of a single
                                                            foreign inqUiry-request signal by providing a branch-
Normal address modifications are not affected.              on-inquiry instruction with a d-modifier. The re-
                                                            quest signal should be a minus N-signal at least two
Prerequisite: Advance Programming.                          microseconds long through the tape connector.

~~ udible stop Signal                          W94783       Branch Non-Numeric Op Code                        M02955
~j.o1   Model A, B, C, D, E, F9 or G                        1401 Model A, B, C, D, E, or F

This feature sounds an alarm when delta process             This feature adds a special d-character to be used
turns off and 1/ 0 operations are complete. The             with the standard V(I)(B)d branch operation. It al-
signal can be heard for a distance of 25 feet. A            lows branching if the character at B contains any
switch is provided to permit manual disabling of the        zone bits, blanks, 8-4, or 8-2-1 bit combinations.
signal.

~3ranch On. Column Binary                       E02364      Branch on Paper Tape Reader Busy                  M94255
].401 Model B, C, E, or F                                   1401 Model B, C, D, E, or F~

A 9-7 combination in column one at the first read           This feature provides for first branch on paper tape
station indicates a column-binary card. The branch-         reader busy operation. The instruction format
on-colunlll--binary instruction tests this condition        $ III d causes a program to branch to the I-address
and sets the reading at the second read station ac-         if the paper tape reader is busy. otherwise the
eordingly. This device permits intermix of                  program continues sequentially   0



eolumn-binary and normal cards with validity
ehecking on normal cards.                                   Prerequisite: RPQ 891050.
                                                                               1401, 1440, 1460 Custom Features        5
Branch Paper Tape Reader Busy-Additional 893043           Branch on Zero Indicator                       M97538
1401 Model B, C, D, E, or F                               1401 Model B, C, D, E, or F

This feature provides an additional branch on paper       This feature provides a branch instruction to test a
tape reader busy instruction. The instruction for-        zero indicator that is set if the arithmetic result of
mat is the same as on RPQ M94255 except that a            an add or subtract operation is zero. Zero indicator
different d-modifier is assigned to each reader.          is to be reset by the next add or subtract operation.

Prerequisite: RPQ 891050 for second reader
              adapter.
              RPQ M94255 for first branch reader          Character Insert on Card Error                 F91948
              busy.                                       1401 Model A, B, C, E, or F

Branch Printer Not Ready                        E17300    This feature inserts a specified character in storage
1401 Model B, C, D, E, or F                               in place of any character giving a validity check when
                                                          read from a card in the 1402. The inserted charac-
This RPQ furnishes a special d-character to be used       ter may be any character that includes zone bits in
with a branch operation to branch on printer-not-         its configuration. The character must be specified
ready in the first printer of a dual printer system.      with the order. Switch control for character inser-
Printer-not-ready consists of end-of-forms, forms         tion is in the 1401.
check, carriage tape brushes up, T-casting open,
clutch light (that is, when the clutch is not in one of       RPQ 812066 is required only if error card count
the four positions), or blown fuseo If branch-            is desired. This feature is not compatible with oper'-
printer-not-ready is desired for second printer,          ation of Column Binary or Punch-Feed Read.
1924-43 must have RPQ 811155.

                                                          Clock Input Adapter -- Hours and              M08400
Branch Printer Not Ready-Second Printer         811155    Hundredths of Hours
1924-43 Dual Printer Adapter                              1401 Model B, C, D, E, or F

This feature furnishes circuitry in the 1924-43 to
                                                          This feature provides the adapter for connecting the
allow branch-printer-not-ready to be operative with
                                                          1998-35 continental clock (hours and hundredths of
the second printer in a dual printer system.
                                                          hours) to the 1401. The clock is addressable under
                                                          instruction format I AAA R and is read out serially
Prerequisite: The 1401 must have RPQ E17300 in-
                                                          to the 1401 storage area speCified by the A-address.
stalled0

                                                          Address modification is plus one. An interlock cir-
                                                          cuit is provided to interlock the 1401 in case a read-
                                                          out is called for while the clock is advancing. Oper-
Branch on Reader Punch Ready                    E01829    ation of this device is not permitted in process over-
1401 Model A, B, or C                                     lap mode. It cannot be used to calculate use time as
                                                          outlined in the sales manual. The device is incom-
This feature provides two branch conditions to allow      patible with any standard, optional, or special de-
reader and punch operations to occur when the 1402        vice using the operation code I.
can accept the command. stacker-switch or jam-
bar troubles will prevent a branch. Hopper empty          Prerequisite: RPQ 813129.
will also prevent a branch with two unprocessed
cards left in the machine.

Branch on Tape Ready Op Code                   W94945     Clock Input Adapter-Hours and Minutes          F89070
1401 Model C, D, E, or F                                  1401 Model B, C, D, E, or F

This feature provides a branch-on-tape-ready com-         This feature reads the same as M08400 except that
mand B(I)d where d is a special character to test         the time is given in hours and minutes, and the 1998
tape-unit status.                                         Model 28 is used.

Limitation: For IBM 729 Magnetic Tape Units only.         Prerequisite: RPQ 812135.

6
Collating Sequence 1401-7090                  M99387    Eliminate Validity Check                               815031
1401 Model B, C, or D                                   1402 Modell

This feature provides, by switch control, a change      This feature furnishes two switches for controlling
in collating sequence between standard 1401 sequence    validity checking by elimination of reading and/ or
and the 7090 sequence.                                  punching the specified columns in the 1401.

Prerequisite: High-Low-equal compare feature.           Prerequisite: RPQ W92900 on the 1401.

Compare Digit Only Op Code                    F91221
,!401 Model B, C, D, E, or F                            Eliminate Validity Check Columns 41-80             W92900
                                                        1401 Model A, B, C, E, F, or G
This feature provides a special operation (Op) code
to compare the digit portion of a character regard-     This feature eliminates validity check by preventing
less of zone information bits.                          reading and/or punching of columns 41-80 to permit
                                                        processing of tumble cards. Read and punch switches
Counter-1403 Line                             811054    are provided.
1401-All ModeLs
                                                        Prerequisite: RPQ 815031 on the 1402.
This feature provides the 1401 adapter to control the
1403 line counter.
                                                        Expanded Alpha                       Special Systems
~:ounter-1403 Line                            E05304                                Feature Bulletin L24-3102
!403 Modell, 2, or 3
                                                        80- and 120-character-set printing for letter writing
This feature provides a six-position, manual-reset      and other special printing jobs requiring more than
counter for counting cumulatively the lines printed     the standard 48-character set. See Special Systems
by a 1403 printer. The counter is mounted under         Feature Bulletin L24-3102 fOll:' description and or-
the covers and in no way limits the standard ma-        dering information.
chine o
                                                        Feed 59/80-Column Adapter                              898074
Prerequisite: RPQ 811054 required on the 1401.          1401 Model B, C, E, or F

Count Error Cards                             812066    This feature consists of the circuitry in the 1401 for
1402 Modell                                             interchangeably reading 59- and 80-column cards.

This feature furnishes a counting device on the 1402
and circuitry in the 1401 to count cards that have      File Adapter 7631 and 1301                         810099
produced a validity error. Switch control for the       1401 Model F
counter will be in the 1402. For use with the 1401
character insertion on card error deviceo               This feature provides the circuitry for attaching an
                                                        IBM 7631 Modell File Control and as many as five
Counter-Read Feed                            M95147     IBM 1301 Modell or 2 Disk Storage units. Attach-
~.402 Modell or 2 (1401)                                ment circuitry in the 1401 replaces the 1405 attach-
                                                        ment circuitry, and the system can be equipped with
This feature consists of a six-position counter,        1301 units only. Field installation is available on
switch-controlled, which counts cards that passed       1401 systems above serial number 25,000 only. The
hole-count and validity check.                          1401 must have 8K or more storage and must have
                                                        sense switches, Feature Code 7600.

~~liminate  A-.bit Printing as Record Mark   W97359
~L401   Model A, B, C, D, or E                          File Interchange                                   E03909
                                                        1401 Model F
This feature changes the circuitry so that an A-bit
only in melnory or print buffer will print nothing.     This feature permits the interchange of one 1405
It presently converts to A-8-2 for printing a record    Modell or 2 between two 1401 systems. Both sys-
lnark"                                                  tems must have power off while interchange is made o

                                                                            1401, 1440, 1460 Custom Features        7
Files, 2 or 31405's on 1401                     F91232   Move Character Instruction                    F91530
1401 Model F                                             1401 Model A, B, C, D, E, or F

This feature modifies the first 1405 Modell or 2         This feature provides programming means for com-
unit to permit attaching one or two additional Model     bining the functions of move numeric and move zone
1 or 2 units (maximum of three to a system) 0            in a single instruction.

Four Additional Sense Switches                  EOl142   Move Character with WM                        811115
1401 Model A, B, C, D, E, F, or G                        1401 Model A, B, C, D, E, F, or G

This feature gives as many as four additional sense      This feature allows modification of move-numeric
switches beyond the seven available as standard          and move-zone operation codes. A single operation
features.                                                takes place in which a move numeric, zone, and
                                                         word mark occurs. A d-character with move Op
Group Mark 12-5-8 or 12-7-8                     M94618   code allows the special operation. The special move
1401 Model A, B, C, E or F                               Op code can be chained.

This feature provides reading and punching of group      Move Records -- With or Without WM           M00732
mark as 12-5-8 or 12-7-8 under switch control. If        1401 Models -- see description
switch is in 12-5-8 mode, 12-7-8 is invalid and vice
versa.                                                   This feature supplies a programming means that
                                                         permits records to be moved from the A-field to the
Hopper Extended Capacity                        M03535   B-field with or without transmission of A-field WM
1402 Modell or 2 (1401)                                  (word marks). The B-field WM will be lost when the
                                                         A-field WM is inhibited with ad-character. Advance
This feature extends the hopper side plates and back     programming is a prerequisite, and this device can
plate to allow insertion of about 2,000 joggled cards    be installed on any 1401 model for which Advance
into the hopper instead of the standard 1,200.           Programming is available.


Magnetic Tape -- Check Point Write              E02881   Paper Tape Input to 1401                     E95528
Instruction                                              1903-2
1401 Model C, D, E, or F
                                                         This RPQ provides a special unit (IBM 1903 Paper
This feature supplies a special write tape operation     Tape Reader Model 2). It is a 500-character-per-
code that recognizes special character (undefined) to    second reader with a 140-character core buffer.
stop tape write. The standard group-mark with word-      The control panel is pluggable for 5-channel tele-
mark is ignored as a control character and is treated    graphic or IBM 8-channel coding. Order must spec-
as any other character. No special read instruction      ify 5- and/or 8-channel operation.
is provided.
                                                         Prerequisite:   RPQ 891050 Serial Input Adapter
Magnetic Tape Release                           E98253                      for 1401.
1401 Model C or D

This feature provides for an operation like read and     Paper Tape Read Modify Operation,            W99246
punch release. It allows processing during start         1011 to 1401
time of a read or write magnetic-tape instruction.       1401 Model B, C, D, E, or F

                                                         This feature modifies the 1401 so that when paper
Modify Address Op Code                          M98528   tape read is terminated by a group-mark with word-
1401 Model B, C, D, or E                                 mark in 1401 core storage, the first character of the
                                                         next record is not lost. The group-mark with word-
This RPQ provides a modify address instruction for       mark is lost but by programming, can be placed
models equipped with 4K or less core storage. This       back in its proper location at the end of the read
instruction operates and takes the same form as the      field before the next block of information is read
modify address instruction provided on 1401' s           from the 1011. This change does not affect the op-
equipped with more than 4K of storage.                   eration of magnetic tape.

8
Paper Tape Serial Input Adapter                     891050    Print Space Suppress                                  898172
1401 Model B, C, D, E, or F                                   1924-43

This feature provides the adapter in the 1401 to per-         This feature is compatible with the space suppres-
mit attachment of the 1903-2 paper tape input unit            sion feature in the 1401 system and requires the
provided by RPQ E9~)528.                                      same Op code once the sec ond 14.03 is selected.

Plotter Attachment to 1407                          W01372
                                                              Printer Space 6-20 LPI                                W96131
1,107 Model 1
                                                              1403 Model 1 or 2 (Factory Only)
This feature provides the circuitry to attach an IBM
                                                              This feature modifies the 1403 to provide 6- or 20-
1<627 Plotter to the 1401 system through the 1407
                                                              LPI spacing. Eight-LPI spacing is not available with
Model 1.
                                                              this feature. Specify maximum form length to be
                                                              used.
Printer - Form Length Extended                      E01<665
1403 Model 1, 2, or 3 (1401)
                                                              Prerequisite:   RPQ 815037 on 1401.
This feature modifies the 1403 carriage control to
use a control tape as long as 40 inches. With a 40-
inch tape, the following maximum form lengths can             Punch Binary and Standard IBM Card                M95242
be used: *                                                    1401 Model A, B, C, E, or F
    40-inch form @ 6 LPI
    30-inch form @ 8 LPI                                      This device provides for the reading and punching of
    24-inch form @ 10 LPI                                     both binary and standard IBM card codes from and
    16-inch form @ 15 LPI                                     into the same cards.
    15-inch form @ 16 LPI
    12-inch form @ 20 LPI
                                                              Punch Buffer                                      E97649
* Prerequisite:   None for standard 6 or 8 lines              1924 Model 44
                     per inch.
                                                              This feature provides a special punch buffer that can
                  RPQ   W91990   for   6 and 10   LPI         be ordered on single or dual 1402 basis. On single
                  RPQ   M98638   for   6, 8 and   10 LPI      basis, the 1402 is attached to the 1401 through the
                  RPQ   W90494   for   6 and 15   LPI         1924-44 box with the 1402 punch side buffered and
                  RPQ   M08444   for   6 and 16   LPI         the read side standard.
                  RPQ   W96131   for   6 and 20   LPI             On the dual basis, the first 1402 is connected to
                                                              the 1401 with read and punch operating normally.
Print Lozenge for GM and Lozenge                    E09787    The second 1402 is connected to the 1401 through
1401 Models (see description)                                 the 1924-44 with the punch side buffered and operable
                                                              as required. The read side of the second 1402 is
This feature makes possible the printing of alozenge          not usable at any time. Single or dual operation
for either BCD code CBA 84 or CBA 8421 in storage,            must be specified.
which covers card codes 12-4-