Service Manuals, User Guides, Schematic Diagrams or docs for : IBM series1 edx 2.0_Apr80 SC34-0316-2_EDX_Communications_and_Terminal_Appications_Guide_Apr80

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
SC34-0316-2_EDX_Communications_and_Terminal_Appications_Guide_Apr80


>> Download SC34-0316-2_EDX_Communications_and_Terminal_Appications_Guide_Apr80 documenatation <<

Text preview - extract from the document
--- -
---- --
- ------
- ---
- - ---
- - .-
--_
-----                                                                         Series/1




           SC34-0316-2                                  LICENSED
                                                        PROGRAM
           File No. S1-30




           IBM Series/1
                 Event Driven Executive
                      Communications and Terminal
                      Applications Guide
                            Program Numbers: 5719-LM5   5719-LM6   5719-MS1
                                             5719-UT3   5719-UT4
                                             5719-XS1   5719-XS2
                                             5719-XX2   5719-XX3
                                             5740-LM2   5740-LM3
--- -
- - --
----
- ------
----
  - ---
-----
--_.-                                                                         Series/1




           SC34-0316-2                                  LICENSED
                                                        PROGRAM
           File No. S1-30




           IBM Series/1
                 Event Driven Executive
                      Communications and Terminal
                      Applications Guide
                            Program Numbers: 5719-LM5   5719-LM6   5719-MS1
                                             5719-UT3   5719-UT4

o                                            5719-XS1
                                             5719-XX2
                                             5740-LM2
                                                        5719-XS2
                                                        5719-XX3
                                                        5740-LM3




o
                                                                         o




Third Edition (APRIL 1980)

Use this publication only for the purpose stated.

Changes are periodically made to the information herein;
before using this publication in connection with the operation
of IBM systems, refer to the latest IB~1 Ser i es/1 Graph i c
Bibliography, GA34-0055, for the editions that are applicable
and current.

It is possible that this    material may contain reference to, or
information about, IBM       products (machines and programs),
programming, or services    which are not announced in your coun-
try. Such references or     information must not be construed to
mean that IBM intends to     announce such IBM products, program-
ming, or services in your   country.

Publications are not stocked at the address given below.
Requests for copies of IBM publications should be made to your
IB~l representat i ve or the IBM branch off i ce serv i ng your local-
it y.

This publication could contain technical inaccuracies or
typographical errors. A form for reader's comments is provided
at the back of this pUblication. If the form has been removed,
address your comments to IBM Corporation, Systems Publica-
tions, Department 27T, P.O. Box 1328, Boca Raton, Florida
33432. IBM may use and distribute any of the information you
supply in any way it believes appropriate without incurring any
obligation whatever. You may, of course, continue to use the
                                                                         ()
information you supply.

(C) Copyright IBM Corporation 1979,1980
    SUMMARY OF AMENDMENTS



    Terminal Support


    Terminal support information for the 3101 Display Termi-
    nal (Models 1 and Model 2) was added to Chapter 1.



    Multiple Terminal Manager


    Chapter 5 has been modified  for PL/I and   3101 Display
    Terminal as provided by the Multiple Terminal Manager.



    Remote Management Utility (Version 2 only)

o   Chapter 6  is a new chapter
    Management Utility.
                                   that describes   the Remote




    The Bibliography lists the    books in the Event  Driven
    Executive library and a   recommended reading sequence.
    Other pUblications related to the Event Driven Executive
    are also listed.



    Miscellaneous Changes


    This manual  has   been modified to include new function
    and  to improve    technical accuracy and clarity.  Addi-
    tional material    and technical changes are indicated by
    vertical bars in   the left margin.



o
                                                 SC34-0316   iii
HOW TO USE THIS BOOK


The material in this section is a guide to the use of this book.
It defines the purpose, audience, and content of the book as
well as listing aids for using the book and background materi-
                                                                                    o
als.



PURPOSE


The IBM Series/l Event Driven Executive Communications and
Term ina I App I i cat ions Gu i de, SC34-0316 descr i bes how to use
the Event Driven Executive to communicate with interactive
devices, such as, terminals or other processors.

This manual provides extensions to the System Guide, the
Utilities, Operator Commands, Program Preparation, Messages
and Codes, and the Language Reference manuals.



AUDIENCE


T his. boo k i s wr itt e n for 5 y s t e man d a p p 1 i cat ion pro g ram mer s
with cons i derab Ie knowledge in BSC and host ope rat ion,. inc I ud-
ing IBM and non-IBM communications hardware.

To write applications for remotely attached devices, you must
be familiar with line control procedures. Experience in pro-
gramming realtime programs in the Event Driven Language is
required. Experience coding programs in assembler language for
the Series/l wi 11 enable you to extend the terminal application
capabilities of the system.



HOW THIS BOOK IS ORGANIZED


This book is organized into two parts. The first part explains
criteria for selecting communications methods or techniques
available with the Event Driven Executive system. The second
part consists of individual chapters which describe how to
design particular communication techniques.




iv   SC34-0316
     The top i cs covered in part two inc I ude:


o        Terminal Support

         Binary Synchronous Communications

         Host Communications Facility

         Multiple Terminal Manager

         Remote Management Utility




     EXAMPLES AND OTHER AIDS


     Throughout this book, coding examples and illustrations are
     used to clarifY coding techniques and requirements. Coding
     examples are fully executable portions of complete programs
     that may be entered as they are shown. Cod i ng ill ustrat ions are
     non-executable portions of incomplete programs that show the
     correct format of all required parameters on a statement. Miss-
     ing code, or code provided by you, is indicated by a series of
     vertical or horizontal dots.

()   Several other aids are provided to assist you in
     book:
                                                                   using     this


     



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo