Text preview - extract from the document
                             CE Mark Information
                             for the PIO-32 Series

                  Note: Products that contain the CE Mark are certified to meet European
                  EMC directive 89/336 EEC. If this directive is not of importance to your
                  application, please disregard the information in this document.


                  Keithley MetraByte certifies that this product has been tested and found
                  to be in compliance with the EMC directive and relevant harmonized
                  standards.

                  This document describes the limitation of certification, the declaration of
                  conformity, and the cabling instructions required for the CE Mark
                  configuration.


Limitation of Certification

                  This certification applies only to the operation of the product (with
                  specified cables and accessories) in the stated configuration and under the
                  stated operational and environmental specifications. Any modification,
                  misuse, or improper or inadequate maintenance of the product by the user
                  voids this certification.

                  Any deviation from the specific configuration may cause emissions or
                  susceptibility not within the allowed limits required by the stated
                  directive. It is the user's responsibility to demonstrate and maintain
                  compliance with the directive and standards.

                  Please read the next section, "Declaration of Conformity," for the specific
                  testing configuration for this product. Consult the Keithley Instruments
                  GMBH office (European importer) or Technical Support in Taunton, MA,
                  USA, for further information regarding the exact configuration details and
                  testing.


Part Number: 24649; Revision A                                                               1
Declaration of Conformity

Application of Council Directive(s)   89/336/EEC
Standard(s) to which Conformity is EN50081-1, EN50082-1
Declared
Manufacturer's Name                   Keithley MetraByte
Importer's Name                       Keithley Instruments GMBH
Importer's Address                    Landsberger Str.65 D-82110 Germering, Munich
Type of Equipment                     Data Acquisition Plug-in Boards
Model Numbers                         PIO-32IN, PIO-32OUT, PIO-32I/O with STP-37/FC,
                                      C-3200, and JACKET shield
Year of Manufacture                   1995


I, the undersigned, hereby declare that the equipment specified above conforms
                   to the above Directive(s) and Standard(s).
Place: Taunton, MA USA
                                      ___________________________________
                                      (Signature)

Date: 01 January 1996                 Mark Urban
                                      (Name)

                                      Quality Assurance Manager
                                      (Position)




2                                                                             December 1995
Cabling Instructions for the CE Mark Configuration

                    Use the C-3200 cable to connect one or more STP-37/FC accessories to a
                    PIO-32 Series board, as shown in Figure 1. Refer to the board's user's
                    guide for more information.

                                                             STP-37/FC
                                                        Screw Terminal Panels




        PIO-32 Series board




                                     C-3200 cables




                         Figure 1. Attaching a PIO-32 Series Board to an STP-37/FC

                    For CE Mark compliance, you must shield the C-3200 cables. The
                    procedure for shielding the cables is as follows:
                    1. With cabling installed and clamped, wrap all cables together with a
                       piece of tape to mark a shield boundary at a point one-half inch or
                       more away from the inside surface of the mounting plate, as shown in
                       Figure 2.


                                                               Mounting Plate


                     PIO-32 Series

                                       Tape Marker  inch
                                      from Mounting Plate


                              Figure 2. Cabling Taped to Show Shield Boundary

                    2. Remove the two clamp-adjusting screws and the clamp from the
                       board's mounting plate.


Part Number: 24649; Revision A                                                            3
3. Unplug the cable connectors from board, and pull the taped cabling
   back through the mounting plate until the tape marker is beyond the
   clamping area.
4. Beginning at the tape marker, cover the cabling with a single piece of
   jacket to the desired length, as shown in Figure 3.


                                     Mounting Plate


     PIO-32 Series




      Figure 3. Cabling Wrapped with Jacket to Tape Boundary

5. Remove tape from cabling, and use scissors to cut -inch flaps in the
   jacket on both sides of cable, as shown in Figure 4.


                                            Fold Line


     PIO-32 Series



                                     inch


    Figure 4. Jacket Trimmed with Scissors to Make -Inch Flaps

6. Fold the flaps back on both sides of cabling to expose the shield
   surface, as shown in Figure 5.

                                     Mounting Plate


    PIO-32 Series
                                    Shield
                                    Surface



 Figure 5. Jacket with Flaps Folded Back to Expose Shield Surface
                  7. Slide cabling back through mounting plate and plug the cable
                     connectors back into the board, placing shield surface directly in line
                     with mounting-plate clamp, as shown in Figure 6.


                                                          Mounting Plate


                    PIO-32 Series
                                                         Shield
                                                         Surface




                   Figure 6. Cabling Reconnected, Placing Shield Surface in Line with
                                               Clamp

                  8. Re-install the clamp and clamp-adjusting screws so that the clamp
                     holds the cabling firmly in place while bearing firmly on the shield
                     surface of the jacket flap, as shown in Figure 7.




                                                                    Trimmed and
                                                                    Folded-back
                                                                     Jacket Flap



                                                                                   Jacket
                                    Cable                                           over
                                                                                   Cable




                                               Clamp




                       Figure 7. Detail of Clamped Cable Showing Installed Jacket


Part Number: 24649; Revision A                                                              5