Text preview - extract from the document
         CE Mark Information for the
         DAS-1600/1400/1200 Series
                  Note: Products that contain the CE Mark are certified to meet European
                  EMC directive 89/336 EEC. If this directive is not of importance to your
                  application, please disregard the information in this document.


                  Keithley MetraByte certifies that this product has been tested and found
                  to be in compliance with the EMC directive and relevant harmonized
                  standards.

                  This document describes the limitation of certification, the declaration of
                  conformity, and the cabling instructions required for the CE Mark
                  configuration.


Limitation of Certification

                  This certification applies only to the operation of the product (with
                  specified cables and accessories) in the stated configuration and under the
                  stated operational and environmental specifications. Any modification,
                  misuse, or improper or inadequate maintenance of the product by the user
                  voids this certification.

                  Any deviation from the specific configuration may cause emissions or
                  susceptibility not within the allowed limits required by the stated
                  directive. It is the user's responsibility to demonstrate and maintain
                  compliance with the directive and standards.

                  Please read the next section, "Declaration of Conformity," for the specific
                  testing configuration for this product. Consult the Keithley Instruments
                  GMBH office (European importer) or Technical Support in Taunton, MA,
                  USA, for further information regarding the exact configuration details and
                  testing.



Part Number: 24637; Revision B                                                               1
Declaration of Conformity

Application of Council Directive(s)   89/336/EEC
Standard(s) to which Conformity is EN50081-1, EN50082-1
Declared
Manufacturer's Name                   Keithley MetraByte
Importer's Name                       Keithley Instruments GMBH
Importer's Address                    Landsberger Str.65 D-82110 Germering, Munich
Type of Equipment                     Data Acquisition Plug-in Boards
Model Numbers                         DAS-1601/CE, DAS-1602/CE, DAS-1201, or DAS-1202
                                      with EXP-1600, an ENCL Series enclosure, FWA-37U,
                                      FWA-EXP, CAB-3740/1/S, STA-U, and S-1800

                                      DAS-1401 or DAS-1402 with EXP-1600, FWA-37U,
                                      FWA-EXP, and CAB-3740/1/S
Year of Manufacture                   1995


I, the undersigned, hereby declare that the equipment specified above conforms
                   to the above Directive(s) and Standard(s).
Place: Taunton, MA USA
                                      ___________________________________
                                      (Signature)

Date: 01 January 1996                 Mark Urban
                                      (Name)

                                      Quality Assurance Manager
                                      (Position)




2                                                                                January 1996
Cabling Instructions for the CE Mark Configuration

                  When using an EXP-1600 as part of the CE Mark configuration, you must
                  use an ENCL Series enclosure. The ENCL-1 supports one EXP-1600, the
                  ENCL-2 supports two EXP-1600s, and the ENCL-4 supports four
                  EXP-1600s.

                  Each version of the ENCL Series enclosure contains slotted card guides
                  and a rear panel that accommodates the rear connectors of each installed
                  EXP-1600. To install an EXP-1600 in an ENCL Series enclosure,
                  perform the following steps:
                  1. Remove the four standoffs from each EXP-1600 to be installed.
                  2. Insert the EXP-1600 into the slots of a pair of card guides.
                  3. Gently push the EXP-1600 toward the rear of the desktop enclosure
                     until the front-panel screws meet the tapped holes on the card guides.
                  4. Fasten the front-panel screws to the card guides.

                  An ENCL-4 containing four EXP-1600s is shown in Figure 1.




              Figure 1. ENCL-4 Enclosure with Four EXP-1600s Installed




Part Number: 24637; Revision B                                                            3
                       Once the EXP-1600 is installed in the ENCL Series enclosure, connect
                       the EXP-1600 directly to the main I/O connector of the
                       DAS-1600/1400/1200 Series board using the CAB-3740/1/S cable, as
                       shown in Figure 2. Figure 2 also shows where to attach the FWA-EXP
                       and FWA-37U. Refer to the DAS board and EXP-1600 user's guides for
                       more information.
     FWA-EXP               FWA-37U


J1                                   P4




                                                                    DAS-1601/CE, DAS-1602CE,
                                                                    DAS-1401, DAS-1402,
                                                                    DAS-1201, or DAS-1202
                EXP-1600
      P2                     P3


                                                          Note: When using an EXP-1600, remember to
                      CAB-3740/1/S                        configure the channels of the DAS board as
                         Cable                            single-ended inputs.


     Figure 2. Connecting the DAS Board to an EXP-1600, FWA-EXP, and FWA-37U

                       The STA-U connects to the DAS-1601/CE, DAS-1602/CE, DAS-1201, or
                       DAS-1202 board via the S-1800 cable, as shown in Figure 3. One end of
                       the S-1800 cable attaches to a connector on the STA-U; the other end of
                       the S-1800 cable attaches to the PIO connector from the DAS board. Note
                       that the DAS-1401 and DAS-1402 boards do not support the STA-U.
                       Refer to your DAS board user's guide for more information.



           J2        PIO cable             S-1800 cable                J1 J2 J3




        DAS-1601/CE, DAS-1602/CE,                                                 STA-U
        DAS-1201, or DAS-1202              pin 1            pin 1

                  Figure 3. Cabling and Connections for Attaching an STA-U