                                          www.keithley.com


2260B Series
360W and 720W Multi-Range Programmable DC Power
Supplies


User Manual
Rev. A / March 2014




 A G reate r Measur e o f Confidenc e
                                           A Tektronix Company
Series 2260B
360W and 720W Multi-Range Programmable DC Power
Supplies




USER MANUAL




             ISO-9001 CERTIFIED MANUFACTURER
This manual contains proprietary information, which is protected by
copyright. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent.

The information in this manual was correct at the time of printing.
However, we continue to improve our products and reserve the rights
to change specification, equipment, and maintenance procedures at
any time without notice.
                                                                  Table of Contents



                 Table of Contents
SAFETY INSTRUCTIONS .................................................... 3

GETTING STARTED ........................................................... 7
            2260B Series Overview ........................... 8
            Appearance .......................................... 12
            Theory of Operation ............................. 18

OPERATION .................................................................... 30
               Set Up .................................................. 31
               Basic Operation ................................... 43
               Parallel / Series Operation ................... 56
               Test Sequence ...................................... 71

CONFIGURATION ........................................................... 83
            Configuration ....................................... 84

ANALOG CONTROL ........................................................ 98
           Analog Remote Control Overview ......... 99
           Remote Monitoring ............................ 115

COMMUNICATION INTERFACE ..................................... 120
           Interface Configuration ...................... 121

MAINTENANCE ............................................................. 132

FAQ ............................................................................... 134

APPENDIX ..................................................................... 136
                2260B Default Settings ...................... 136
                Error Messages & Messages .............. 138
                LED Display Format ........................... 138

                                                                                      1
                                                       2260B Series User Manual

                      2260B Specifications .......................... 139
                      2260B Dimensions ............................. 145
                      Declaration of Conformity .................. 147

INDEX ............................................................................ 148




2
                                             SAFETY INSTRUCTIONS




SAFETY INSTRUCTIONS
                 This chapter contains important safety
                 instructions that you must follow during
                 operation and storage. Read the following before
                 any operation to insure your safety and to keep
                 the instrument in the best possible condition.


Safety Symbols
These safety symbols may appear in this manual or on the
instrument.


                 Warning: Identifies conditions or practices that
    WARNING      could result in injury or loss of life.

                 Caution: Identifies conditions or practices that
    CAUTION      could result in damage to the instrument or to
                 other properties.

                 DANGER High Voltage

                 Attention Refer to the Manual


                 Protective Conductor Terminal


                 Earth (ground) Terminal




                                                                    3
                                                      2260B Series User Manual


                    Do not dispose electronic equipment as unsorted
                    municipal waste. Please use a separate collection
                    facility or contact the supplier from which this
                    instrument was purchased.


Safety Guidelines

General Guideline      Do not place any heavy object on the
                       instrument.
    CAUTION            Avoid severe impact or rough handling that
                       leads to damaging the instrument.
                       Do not discharge static electricity to the
                       instrument.
                       Use only mating connectors, not bare wires, for
                       the terminals.
                       Do not block the cooling fan opening.
                       Do not disassemble the instrument unless you
                       are qualified.
                    (Measurement categories) EN 61010-1:2001 specifies the
                    measurement categories and their requirements as follows. This
                    instrument falls under category II.
                     Measurement category IV is for measurement performed at the
                     source of low-voltage installation.
                     Measurement category III is for measurement performed in the
                     building installation.
                     Measurement category II is for measurement performed on the
                     circuits directly connected to the low voltage installation.
                     Measurement category I is for measurements performed on
                     circuits not directly connected to Mains.

Power Supply           AC Input voltage range: 85VAC~265VAC
                       Frequency: 47Hz~63Hz
    WARNING
                       To avoid electrical shock connect the protective
                       grounding conductor of the AC power cord to
                       an earth ground.



4
                                                   SAFETY INSTRUCTIONS


Cleaning the      Disconnect the power cord before cleaning.
Instrument        Use a soft cloth dampened in a solution of mild
                  detergent and water. Do not spray any liquid.
                  Do not use chemicals containing harsh material
                  such as benzene, toluene, xylene, and acetone.

Operation         Location: Indoor, no direct sunlight, dust free,
Environment       almost non-conductive pollution (Note below)
                  Relative Humidity: 20%~ 85%
                  Altitude: < 2000m
                  Temperature: 0



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo