Text preview - extract from the document
9450A Portable, Dual-Channel
Digital Oscilloscope



Main Features
I 50K memory per channel
     Automatic PASSIFAILtesting on
     templates and parameters

     Segmentable memories with trigger
     point time stamps

     FASTGLITCH trigger mode

     Signal processing and FFT analysis

m    Optional high speed memory card

D    Unmatched display quality

     TV trigger and XY display



The Ultimate Instrument
for Design and Test
The LeCroy 9450A combines high                 The 9450A is shown measuring a frequencyshitfkeyed signal. The FFT of the waveform is
                                               shown in the lower trace, indicating peaks at 1 MHz and 1.5 MHz.
bandwidth, fast sampling rates, high
fidelity, extensive trigger capabilities and
signal processing. Aimed at meeting the
demands of researchers and engineers
working in fields as diverse as telecom-
                                               Functional Description                         including spikes and glitches. It is fully
                                                                                             oroarammable over GPlB or RS-232-C
munications, electronic design and test,                                                     ;nt&aces. Hard copies are made at the
lasers, computers, NDT, physics and            The LeCray 9450A Dual-channel Digital         touch of a button on a wide range of
defense, the 9450A will rapidly become         Oscilloscope is a pawertul high-resolu-       digital ploners and printers.
an indispensable measurement tool in           fion instrument for waveform recording
any laboratory.                                and sophisticated analysis. It provides a     ANALOG FEEL, DIGITAL PRECISION
                                               bandwidth of 300 MHz, and sampling
Like all LeCroy oscilloscopes, the              rates of up to 400 MSIsec for transients     The 9450A employs Flash technology in
9450A i designed to serve as a range
         s                                     and 10 GS/sec for repetitive waveforms.       its two high-resolution, 8-bit ADCs (one
of different instruments: oscilloscope,        The instrument features high-fidelity,        per channel) which digtize waveforms
transient recorder, counterftimer,             8-bit ADCS, 50K of non-volatile acquisi-      with speed and precision. By combining
frequency meter, signal averager, data         tion memory per channel, 200K of              this technology with ease of use,
\ogger and digits\ vohmeter. \t offers the     addiliona\ waveform storage memory,           LeCroy's portabie instrument provides
highest performing data acquisition and         extensive pulse parameter analysis, and      the best leatures of both analog and
processing system available in any              a highly sophisticated trigger system to     digital oscilloscopes.
portable instrument.                           capture the most complex signals,
The front-panel controls of the 9450A         TRIGGER                                      For instance, the oscilloscope can be set
have been laid out in the style of an                                                      up to PASS if:
analog oscilloscope, making it easy to        Push-button control enables the user to
use from the very first moment. The           choose the appropriate trigger functions      1, The waveform in Channel 1 is
analog feel is enhanced by the rapid          for his signal: standard triggering for          contained in the mask in Memory C
instrument response and the fact that         basic measurements and advanced                   (all points inside the mask).
waveforms are presented instantly on          triggering to meet highly sophisticated
a bright high-resolution screen. For          requirements.                                 2. The frequency in Channel 2 is less
automated test applications at1 the                                                            than 10 kHz.
front-panel controls, including cursor        The standard trigger facility provides all
positions and internal functions, are fully   the conventional trigger functions. Front-    3. The maximum value of Function F
programmable over RS-232-C or GPlB            panel controls select and adjust param-          is more than 1.45 V.
interfaces.                                   eters such as pre- and post-trigger
                                              settings, trigger level, slope, mode and      4. The RMS value in Channel 1 is
Capturing and measuring signals has           coupling. To help users quickly deter-           less than 850 mV.
never been easier. For repetitive signals     mine the 9450A's trigger mode and
an auto-setup facility finds and displays     conditions, LeCroy has created a series      If any of these four conditions is not
signals in less than 2 seconds. For one-      of illustrative trigger graphics.            satisfied, the test will FAIL.
time phenomena the 9450A's long 50K
memories and extensive triggering             SMART triggering offers a solution to        Whether the test PASSes or FAILS,the
capabilities enable signals to be cap-        even the most intricate triggering           oscilloscope can, if the user wishes,
tured the very first time, even when          problems. For example, FASTGLITCH            perform any or all of the following
signal speed and duration are uncertain.      trigger can be used to locate and reveal     actions:
                                              glitches and spikes less than 2.5 nsec
LONG NOH-VOLATILEMEMORIES                     wide. Time-qualified trigger is ideal for     - Stop the acquisition.

Only long memories allow high-fidelity
                                              ranging applications and can be used to
                                              ignore unwanted signal ref[ections. Other
                                                                                            -   Make a screen dump.
recording over extended periods of time.      trigger features include hold-off (by time    - Store a trace to Memory D.
On equal time-base settings the 9450A,        or number of events), gated triggering        -   Store the selected traces to the
with 50K of memory per channel, will          and conditional triggering, qualified             memory card.
sample waveforms up to 50 times faster        trigger, and trigger delayed by time or
                                              number of events.
                                                                                            -   Emit a "beep".
than an oscilloscope with only 1K of
memory. Faster sampling means better                                                        -   Send a pulse from the rear-panel
single-shot bandwidth, better time                                                              accessory port.
resolution and the power to expand
waveforms up to 1000 times to see             The PASSiFAlL routine enables the            The mask envelope can also be gener-
details that completely elude other           oscilloscope to compare a source trace       ated inside the oscilloscope.
digital oscilloscopes. In addition, when      against a tolerance mask while simulta-
segmented, the 9450A's non-volatile           neously testing a set of extracted
acquisition memories can store up to          parameters.
200 waveforrns/channel (complete with
date and time stamps).
9450A Specifications

\/ERTICAL ANALGC; SECTION                           VERTICAL DIGITAL SECTION                            HORIZONTAL SECTION
Bandwidth (-3 dB):                                  ADCs: One per channel, &bit Flash.                  Time Base
@ 50 ii, DC to 300 MHz                              Conversion rate: Up to 400 MSIsec for               Range: 1 nsecldiv to 5000 secidiv.
@ 1 M . DC DC to 250 MHz typical at the
       i!                                           transients, up to 10 GS/sec for repetitive          Clock accuracy: 5 -10.002"/0.
probe t ~ p                                         slgnals, s~multaneouslyon both channels.            lnterpolator resolution: 5 psec.
Input impedance: 1 MQ1l 5 pF and                    Aperture uncenalnty: +I 0 psec.                     Interpolator accuracy: 20 psec RMS.
50 Cl11%                                            Acquisition memories, Channel 1 and 2:              Sampling clock output: BNC connector on
Channels: Two Independent channels;                 Non-volallle memories (battery backed for           rear panel.
standard BNC connector lnputs                       a rnlnlmum of 2 years) of 50 kllowords per
                                                                                                        External clock in: BNC connector on rear
Sensitivity range: 5 mV:dtv to 2 Vidiv,             channel can be segmented into 2,5, 10, 20,
                                                                                                        panel.
continuously var ab e from 1 to 2 5 trmes           50. 100 or 200 segments.
the flxed setlrng F~xed   settlngs range frow       Reference memories, C and D: 50K. 16-bit
                                                    word rnernorles whlch can store one acquired        Acquls~t~on    Modes
5 mV1d1v 2 Vldlv (In a I 2, 5 sequence)
            to
                                                    andlor processed waveform, or up to 205             Rendom Interleaved Sampling (RIS):
Vertical expansion: Up to 5 tlrnes (wlth                                                                For repetltlve signals from 1 nsectd~v
averaging up to 50 l~mes 100 rnV/dlv
                             or                     waveforms when segmented.
                                                    Function memories E and F: Two 50K, 16-             to 5 psecidlv.
sensltrvlty).
                                                    bjt word memo-ies for waveform processing.          S~ngle   shot: For translent s~gnalsand
Scale factors: Probe attenuation factors of                                                             repetitive slgnals from 10 nsectdlv to
X I X l o , X100, XlG00 X10G00 may be
                                                                                                        200 msecld~v
selected and are remotely programmable              PEAK AND GLITCH DETECTION
                                                                                                        Roll: For s owly changlng s~gnals  from
Offset: i 1 2 times the flxed ssnsitivity setting   Minimum and maximum peaks, as fast as
                                                                                                        500 rnsecidiv to 5000 sec!d~v
 In 0 02 drv~s~on increments up to 5 ' 0 V rnax ;   0.002% of the record length (minimum
j;24 dlv @ 10 mV~div,    248 drv @ 5 mVidiv         2.5 nsec), are captured and displayed with          Sequence mode: D~vldes acqulsll~on
                                                                                                                                     the
                                                    100% probabili:y. Using LeCroy's new                memory inlo 2, 5 10, 20, 50, 100 or 200
 DC accuracy: 