Service Manuals, User Guides, Schematic Diagrams or docs for : LeCroy LeCroy_LC334A_LC574AL_Datasheet

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
LeCroy_LC334A_LC574AL_Datasheet


>> Download LeCroy_LC334A_LC574AL_Datasheet documenatation <<

Text preview - extract from the document
LeCroy LC334A Series Digital Oscilloscope                                                                                          Page 1 of 11




                                                                                                               Search:



Home | About LeCroy | Products | Solutions | Service & Support | Technical Library | Request Quote | Request Info | International Sites


PRODUCTS
 Oscilloscopes
Protocol Analyzers
Differential Amplifiers
                               LC334A
 Probes                        LC574A
Automotive/Vehicle Test
Mixed Signal Test Solutions
                               Datasheet
Modular Instruments
Scope Accessories              Leading Specifications
Hardware Options
                                       500 MHz and 1 GHz Bandwidth
Software Options
                                       2 GS/s and 4 GS/s Single- Shot Sample Rate
Discontinued Products
                                       8 Million Points of Acquisition Memory
                                       4 ms Maximum Sample Rate Window
                                       96 MHz PowerPC Microprocessor
                                       8 to 64 MB System RAM
                                       9" Color Display with 8 Traces
                                       Analog Persistence
                                       Full Screen Grid




                               Digital oscilloscopes from LeCroy are designed to save engineers valuable time in troubleshooting
                               and problem-solving.


                               Each oscilloscope is an integrated and powerful system providing the capability to:


                                       Capture the key events with high resolution for longer time intervals


                                       View data like never before, giving you more information more quickly, with a large,
                                       color CRT and advanced display techniques


                                       Analyze your signal to get answers quickly and more accurately with a powerful
                                       processing system and math packages.


                                       Eight trace display for a more complete picture.


                               9" Color Display

                               LeCroy provides a very large, sharp oscilloscope screen that is 50% larger
                               in total viewing area than a 7" screen.

                               Its powerful features include Analog Persistence, Color-Graded
                               Persistence, Full Screen mode, Opaque or Transparent display, color
                               association, and personal color schemes. These provide the user with
                               outstanding benefits that accelerate visual processing and effective
                               communication of on-screen information.

                               High-Speed Acquisition

                               The design and debug of fast digital systems and the need to capture fast
                               transient signals require high-speed signal capture. The LC574A four-
                               channel, 1 GS/s, 1 GHz bandwidth DSO operates at a 4 GS/s sample rate
                               for single-channel inputs. The high sample rate, bandwidth and the 1 GHz
                               trigger bandwidth provide a flexible solution for capturing and viewing
                               fast risetime signals.

                               Large Sample Rate Window

                               Having a high sample rate in a DSO is only the first step to preserving
                               data integrity. The time window over which this sample rate is available is
                               also of critical importance. Long acquisition memory maintains the




http://www.lecroy.com/tm/products/Scopes/LCSeries/LC334/default.asp                                                                  1/31/2007
LeCroy LC334A Series Digital Oscilloscope                                                          Page 2 of 11



                     oscilloscope's highest sample rate for large time windows allowing the
                     user to sample long signals with high horizontal resolution.

                     With up to 8 million points of acquisition memory, the maximum sample
                     rate of the LC574AL of 4 GS/s (2 GS/s in LC334AL) is maintained for a
                     time window of 2 ms (4 ms in LC334AL). This sample rate window
                     enables the user to record long signals with high resolution.

                     Optimum Performance

                     SMARTMemory is a total memory management system that dynamically
                     allocates resources of microprocessor power, acquisition memory and
                     processing RAM. The intelligent management provided by SMARTMemory
                     guarantees optimal usage of oscilloscope resources.

                     The 96 MHz PowerPC microprocessor at the heart of these DSOs drives
                     the system to produce results fast, providing rapid waveform update and
                     super panel responsiveness.

                     Quick Diagnoses

                     Capturing and viewing waveforms are fundamental to an oscilloscope.
                     Productivity improvements are accessible by using built-in math functions
                     to assist troubleshooting and diagnoses of circuit problems.

                     The signal analysis capability of these DSOs is enhanced by advanced
                     waveform math, spectrum analysis, and waveform parameter analysis.
                     This analysis capability greatly increases the speed with which circuit
                     problems are clearly identified and solved.

                     Analog Persistence

                     At a push of the green button, the user can switch between an analog
                     style view and a digital view of signals on these oscilloscopes.

                     The depth of signal information can be explored along the third dimension
                     of the waveform display to give the user a complete picture of waveform
                     activity.

                     Unlike an analog oscilloscope, all signal data is captured and available in
                     memory for analysis and measurements. Analog Persistence gives the
                     user the best of both the analog and digital worlds of oscilloscopes.

                     Full Screen Grid

                     LeCroy DSOs not only have a very large 9" screen but also provide a
                     display mode with an extra-large grid, up to 150% larger than common
                     grid areas. In Full Screen mode, all of the screen area is used to display
                     signals. This provides a magnificent view of up to 8 waveforms: signal
                     details are seen more clearly and with greater ease.

                     8-Trace Display

                     An 8-trace display with any combination of math functions, zooms,
                     reference memories, or channels is a standard feature in the LC series.

                     Octal grid display is available in normal and Full Screen display modes,
                     with and without parameters displayed.

                     Easy Documentation

                     All waveform data and results of analysis can be quickly saved to floppy
                     disk, memory card, ATA flash card, or a removable hard disk. This
                     provides an efficient way to archive information and facilitates easy




http://www.lecroy.com/tm/products/Scopes/LCSeries/LC334/default.asp                                  1/31/2007
LeCroy LC334A Series Digital Oscilloscope                                                        Page 3 of 11



                     documentation of results.

                     An internal graphics printer (standard in "L" models) outputs screen
                     dumps in seconds providing the user with an immediate and clear record
                     of signal activity.

                     Signal Capture

                     Acquisition System

                     LC334A Bandwidth (-3 dB): @ 50 ohm: DC to 500 MHz

                     LC574A Bandwidth (-3 dB): @ 50 ohm: DC to 1 GHz

                     Bandwidth (-3 dB): @ 1 Mohm: DC to 500 MHz typical at probe tip with
                     optional 1 GHz FET probe for LC334A and with PP005 standard with
                     LC374A and LC574A.

                     No. of Channels: 4

                     No. of Digitizers: 4

                     Max. Sample Rate Window:

                     4 ms @ 2 GS/s in single-shot mode; LC334AL.
                     2 ms @ 4 GS/s; LC574AL.

                     Sensitivity LC334A:

                     2 mV/div to 5 V/div, 50 ohm, fully variable.
                     2 mV/div to 5 V/div, 1 Mohm, fully variable.

                     Sensitivity LC574A:

                     2 mV/div to 1 V/div, 50 ohm, fully variable.
                     2 mV/div to 10 V/div, 1 Mohm, fully variable.

                     Scale factors: A wide choice of probe attenuation factors are selectable.

                     Offset Range LC334A:

                     2.00 - 9.99 mV/div: 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo