      TELEVISION/MONITOR SAFETY GUIDELINES FOR THE PROFESSIONAL SERVICE TECHNICIAN

Safety Checks
After the original swevice problem has been corrected,a complete safety
check                                                                              6. New picture tubes are specifically designed to withstand higher operathng
should be made. Be sure to check over the entire set, not just the areas               voltages without creating undesirable X-radiation. It is strongly
where you have worked. Some previous servicer may have left an unsafe                  recommended that any shop test fixture which is to be used with the new
condition,which could be unknowingly passed on to your customer. Be sure               higher voltage chassis be equipped with one of the new type tubes
to check all of the following:                                                         designed for this service.Addition of a permanently connected HV meter
Fire and Shock H azard                                                                 to the shop test fixture is advisable. The CRT types used in these new
1. Be sure all components are positioned in such a way as to avoid the                sets should never be replaced with any other types,as this may result in
   possibility of adjacent component shorts. This is especially important              excessive X-radiation.
   on those chassis which are transported to and feom the service shop.            7. It is essential to use the specified picture tube to avoid a possible X-diation
2. Never release a repaired unit unless all protective devices such as                 problem.
    insulators, barries, covers, strain reliefs, and other hardware have been      8. Most TV receivers contain some type of emergency "Hold Down" circuit to
    installed in accordance with the original design.                                  pervent HV from rising to excessive levels in the presence of a failure
3. Soldering and wiring must be inspected to locate possible cold solder               mode. These various circuits should be understood by all technicians
    joints,solder splashes,sharp solder points, frayed leads, pinched leads,           servicing them, especially since many hold down circuits are inoperative
   or damaged insulation ( including the ac cord).Be certain to remove                 as long as the receiver performs normally.
    loose solder balls and all other loose foreign particles.
4. Check across-the-line components and other components for physical              Leakage Current Cold Check
                                                                                   1. Unplug the ac line cord and connect a jumper between the two prongs of
    evidence of damage or deteriortion and replace if necessary. Follow
                                                                                       the plug.
    original layout,lead length, and dress.
                                                                                   2. Turn on the power switch.
5. No lead or component should touch a receiving tube or a resistor rated
                                                                                   3. Measure the resistance value between the jumpered ac plug and all
    at 1 watt or more. Lead tension around protruding metal surfaces or
                                                                                      exposed cabinet parts of the receiver, such as screw heads, antennas,
    edges must be avoided.
                                                                                      and control shafts.When the exposed metallic part has a return path to
6. Critical components having special safety characteristics are identified
                                                                                      the chassis, the reading should be between 1 megohm and 5.2 megohms.
    with ans bythe Ref. No. in the parts list and enclosed within a broken line
                                                                                      When the exposed metal does not have a return path to thr chassis, the
     * (where seceral criticalcomponents are grouped in one area) along with
                                                                                      reading must be infinity.Remove the jumper from the ac line cord.
   the safety symbols on the schematic diagrams and/or exploded views.
7. When servicing any unit, always use a seoparate isolation transformer
   for the chassis Failure to use a separate isolation transformer may
   exopose you to possible shock hazard, and may cause damage to
   servicing instruments.
8. Many electronic products use a polarized ac line cord (one wide pin on
   the plug.) Defeating this safety feature may create a potential hazard to
   the service and the user. Extension cords which do not incorporate the
   polarizing feature should never be used.                                        TO                                 0.15 uF                            WATER
9. After reassembly of the unit, always perform an leakage test or resistance      INSTRUMENTS                                                           PIPE
   test from the line cord to all exposed metal parts of the cabinet. Also check   EXPOSED                                                               EARTH
   all metal control shafts(with knobs removed), antenna terminals, handles,       METAL PARTS                  1500 ohm, 10W                            GROUND
   screws, etc. to be sure the unit may be safety operted without danger of
   electrical shock.
                                                                                   Leakage Current Hot Check
                                                                                   1. Do not use an isolation transformer for this test. Plug the completely
* Broken line
                                                                                       reassembled receiver directly into the ac outlet.
                                                                                   2. Connect a 1.5k, 10w resistor paralleled by a 0.15uf. capacitor between
Implosion
                                                                                       each exposed metallic cabinet part and a good earth ground such as a
1. All picture tubes used in current model receivers are equipped with an
                                                                                       water pipe, as shown above.
   intergral implosion system. Care should always be used, and safety
                                                                                   3. Use an ac voltmeter with at least 5000 ohmsy volt sensitivity to measure
   glassesworn,whenever handling any picture tube. Avoid scratching or
                                                                                      the potential across the resistor.
   other rwise damaging the picture tube during installation.
                                                                                   4. The potential at any point should not exceed 0.75 volts. A leakage current
2. Use only replacement tubes specified by the manufacturer.
                                                                                       tester may be used to make this test; leakage current must not exceed
X-radiation                                                                            0.5 milliamps. If a measutement is outside of the specified limits, there is
1. Be sure procedures and instructions to all your service personnel cover            a possibility of shock hazard. The receiver should be repaired and
    the subject of X-radiation. Potential sources of X-rays in TV receivers are       rechecked before retutning it to the customer.
    the picture tube and the high voltage circuits. The basic precaution which     5. Repeat the above procedure with the ac plug reversed.( Note: An ac
    must be exercised is to keep the high voltage at the factory recommended           adapter is necessary when a polarized plug is used. Do not defeat the
    level.                                                                             polarizing feature of the plug.)
2. To avoid possible exposure to X-radiation and electrical shock, only the
    manufacturer's specified anode connectors must be used.                        Picture Tube Replacement
                                                                                   The primary source of X-radiation in this television receiver is the picture
3. It is essential that the service technician has an accurate HV meter
                                                                                   tube.The picturetube utilized in this chassis is specially constructed to limit
   available at all times. The calibration of this meter should be checked
                                                                                   X-radiation emissions. For continued X-radiation protection, the replacement
   periodically against a reference standard.
                                                                                   tube must be the same type as the original, including suffix letter,or a Philips
4. When the HV circuitry isoperating properly there is no possibility of an x-
                                                                                   approved tupe.
   radiation problem. High voltage should always be kept at the anufacture,s
   rated value-no higher - for optimum performance. Every time a color set is
                                                                                   Parts Replacement
   serviced, the brightness should be run up and down while monitoring the
                                                                                   Many electrical and mechanical parts in Philips television sets have special
   HV with a meter to be certain that the HV is requlated correctlv and does
                                                                                   safety related charcteristics. These characteristics are often not evident from
   not exceed the specified value. We suggest that you and your technicians
                                                                                   visual inspection nor can the protection afforded by them necessarily be
   review test procedures so that HV requation are always checked as a
                                                                                   obtained by using replacement components rated for higher voltage, wattage,
   standard servicing procedure, and the reason for this prudent routine is
                                                                                   etc. The use of a substitute part which does not have the same safety
   cleary understood by everyone. It is important to use an accurate and
                                                                                   characteristics as the Philips recommended replacement part shown in this
    reliable HV meter. It is recommended that the HV recorded on each
                                                                                   service manual may create shock, fire, or other hazards
    customer's invoice, which will demonstrate a proper concern for the
    customer's safety.
5. When troubleshooting and making test measurements in a receiver with
     a problem of excessive high voltage, reduce the line voltage by means of
     a Variac to bring the HV into acceptable limits while troubleshooting. Do
     not operate the chassis longer than necessary to locate the cause of the
     excessive HV.

        WSRNING : Before removing the CRT anode cap, turn the unit OFF and short the HIGH VOLTAGE to the CRT DAG ground.
     SERVICE NOTE : The CRT DAG is not at chassis ground.