Service Manuals, User Guides, Schematic Diagrams or docs for : Philips Monitor CD 2001 Monitor CD 2001 E-MANUALS Philips crt 107b2 pdf p06
<< Back |
HomeMost service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download
Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing.
If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.
Image preview - the first page of the document
Preview not available!
Sorry, no preview image available for this document.
Possible reasons are : this is not a PDF document, it is password protected or the file is partially corrupted.
We are working to fix the issue.
You can still download the full file from the link below and it will be viewable.
>> Download p06 documenatation <<Text preview - extract from the document 6 107B2 CM24 GSIII OSD Lock Function & Service Mode
9 Go to cover page
To lock (disable) OSD function:
Access Factory Mode
- Press OSD button " " for over 15 seconds to lock the OSD function. Firstly, get into Factory Adjustment Mode.
Release it, then OSD comes on the screen as below.
Push LEFT & RIGHT buttons at the same time for
over 15 seconds and release them.
ATTENTION The factory message appears at the bottom of the
main OSD menu. (for example : GS3 107B2 V1.41 20000630;
CONTROL MENU IS LOCKED 00115 is M.used hours)
00115
To unlock (enable) OSD function:
- Press OSD button " " for over 15 seconds again to unlock the
OSD function.
Release it, then OSD comes on the screen as below.
GS3 107B2 v1.41 20000630
Access Service Mode
- Disconnect the Interface cable of the monitor.
- Push LEFT & RIGHT buttons at the same time, then power
ON.
- If it is successful, the signal " "
comes on the screen later. SERVICE MODE
MODEL SELECT (Background is white.). SERIAL NO: TY 123456
HOURS : 00021
FACTORY VER 1.01 990706
Exit "Service Mode" :
GS3 107B2 V1.41 20000630 - Apply a normal VGA Signal to monitor, then monitor will exit " service
mode" back to normal.
Disable/Enable all the WARNING SIGNAL
To disable all the WARNING SIGNAL :
- Disconnect the Interface cable of the monitor (Monitor is ON.).
- Press OSD button " " for over 15 seconds to disable all the
WARNING SIGNAL. Then release the "OSD" button.
- If it is successful, then the signal " NO SIGNAL INPUT "disappeared to
enter power saving-off mode.
To enable all the WARNING SIGNAL :
- After disconnect the Interface cable of the monitor, then Monitor is
powered ON.
- If it is successful, the signal " NO SIGNAL INPUT " comes on the
screen again later.