 10     107B2 CM24 GSIII                                       DDC Instructions
      Go to cover page

1. General                                                                 3. Pin assignment
DDC Data Re-programming
                                                                             A. 15-pin D-Sub Connector
In case the main EEPROM with Software DDC which store all factory
settings were replaced because a defect,repaired monitor the serial
numbers have to be re-programmed.

It is advised to re-soldered the main EEPROM with Software DDC from
the old board onto the new board if circuit board have been replaced, in
this case the DDC data does not need to be re-programmed.                         The 15-pin D-sub connector (male) of the signal cable
                                                                                  on the 3rd row for DDC feature :
Additional information

Additional information about DDC (Display Data Channel) may be
obtained from Video Electronics Standards Association (VESA).
Extended Display Identification Data(EDID) information may be also
obtained from VESA.
                                                                                          1                             5
DDC EDID structure                                                                        6                             10
For the monitor   : Standard Version 3.0                                                 11                             15
                    Structure Version 1.2



2. System and equipment requirements
1. An i486 (or above) personal computer or compatible.
2. Microsoft operation system Windows 95/98.                                Pin No.      Assignment
3. EDID301.EXE program (3138 106 10103) shown as Fig. 1                       1          Red video input
4. Software DDC Alignment kits (4822 310 11184) shown as Fig. 2.
The kit contents: a. Alignment box x1                                         2          Green video input
                  b. Printer cable x1                                         3          Blue video input
                  c. D-Sub cable x1
                                                                              4          Identical output - connected to pin 10
    Note: The EDID301.EXE (Release Version 1.58, 20000818)is a                5          Salf test
    windows-based program, which cannot be run in MS-DOS.                     6          Red video ground
                                                                              7          Green video ground
                                                                              8          Blue video ground
                                                                              9          No pin
                                                                             10          Logic ground
                                                                             11          Identical output - connected to pin 10
                                                                             12          Serial data line (SDA)
                                                                             13          H. Sync / H + V
                               EDID301.EXE
                                 Ver:1.58                                    14          V. Sync (VCLK for DDC)
                                                                             15          Data clock line (SCL)
                Figure 1 Diskette with EDID301.EXE


                         DC 8V~12V           Power indicator

                         To Monitor            To Printer




                                   Video Card




                         Fig. 2 Alignment Kits




   Back                                                                                                                           Forward
                                                                    DDC Instructions (Continued)                                           107B2 CM24 GSIII            11
                                                                                                                                                 Go to cover page

4. Configuration and procedure                                                                    3. At the submenu, type the letter of your computer's floppy disk drive
                                                                                                     followed by :EDID301 (for example, A:\EDID301, as shown in Fig. 5).
There is no Hardware DDC (DDC IC) anymore. Main EEPROM stores
all factory settings and DDC data (EDID code) which is so called
Software DDC. The following section describes the connection and
procedure for Software DDC application. The main EEPROM can be re-                                                                                                Fig. 5
probrammed by enabling "factory memory data write" function on the
DDC program (EDID301.EXE).



*** INITIALIZE ALIGNMENT BOX ***

In order to avoid that monitor entering power saving mode due to                                  4. Click OK button. The main menu appears (as shown in Fig. 6).
sync will cut off by alignment box, it is necessary to initialize                                    This is for initialize alignment box.
alignment box before re-programming DDC Data. Following steps
show you the procedures and connection.
                                                                                                                                                                  Fig. 6
Step 1: Supply 8~12V DC power source to the Alignment box by
        plugging a DC power cord or using batteries.
Step 2: Connecting printer cable and video cable of monitor as
        shown in Fig.3.



              PC

                                                           Fig. 3
                                                                                                  Note 1: If the connection is improper, you will see the following error
                                                                                                          message (as shown in Fig. 7) before entering the main menu.
                                                                                                          Meanwhile, the (read EDID) function will be disable. At this time,
                       To printer port (LTP1)




                                                                                                          please make sure all cables are connected correctly and fixedly,
                                                                       Rear view of the monitor           and the procedure has been performed properly.
                                                DC Power
       To video card




                                                 8~12 V
                                                      ~
                                                                                                                                                Fig. 7
                                                          To
                                                          Monitor
                                                Printer
                                                Port

                                                           To PC
                                                                        Video cable
                                                                                                  Method 2: After create a shortcut of EDID301.EXE
                                                                                                       : Double click EDID301 icon          (as shown in Fig. 8) which is
                                                                                                         on the screen of Windows Wallpaper.
                                                                                                         Bring up main menu of EDID301 as shown in Fig. 9.
Step 3: Installation of EDID301.EXE                                                                      This is for initialize alignment box.
Method 1: Start on DDC program
Start Microsoft Windows.
1. Insert the disk containing EDID30.EXE program into floppy disk drive.
2. Click          , choose Run at start menu of Windows 95/98 as
   shown in Fig. 4.


                                                                                                                 1
                                                                                                           Fig. 8
                                                                                                                                              Fig. 9
                                                                                                  Note 2: During the loading, EDID301 will verify the EDID data which just
                                                                                 Fig. 4                   loaded from monitor before proceed any further function, once
                                                                                                          the data structure of EDID can not be recognized, the following
                                                                                                          error message will appear on the screen as below. Please
                                                                                                          confirm following steps to avoid this message.
                                                                                                          1. The data structure of EDID was incorrect.
                                                                                                          2. DDC IC that you are trying to load data is empty.
                                                                                                          3. Wrong communication channel has set at configuration setup
                                                                                                             windows.
                                                                                                          4. Cables loosed or poor contact of connection.




3Back                                                                                                                                                         Forward4
 12     107B2 CM24 GSIII                                                DDC Instructions (Continued)
      Go to cover page

Re-programming EEPROM (Software DDC)                                                                 4. Click     icon (Read EDID function) to read DDC EDID data from
Step 1: After initialize alignment box, connecting all cables and                                       monitor. The EDID codes will display on screen as shown in Fig. 13.
        box as shown in Fig. 10


                                                                        Rear view of the monitor                                                                                      Fig. 13
                PC
                                                   Fig. 10
                          To printer port (LTP1)




                                                   DC Power
          To video card




                                                    8~12 V                                           Step 3: Modify DDC data (verify EDID version, week, year)
                                                         ~
                                                                                                     1.      Click     (new function) icon from the tool bar, bring up
                                                                       Video cable                           Step 1 of 9 as shown in Fig. 14 .
                                                             To                                              EDID301 DDC application provides the function selection and
                                                   Printer
                                                             Monitor
                                                                                                             text change (select & fill out) from Step 1 to Step 9.
                                                   Port

                                                              To PC




Step 2: Read DDC data from monitor

1-1 Click the left key of Mouse, or hit any key on the keyboard,
     then the characters disappear from the screen.
                                                                                                                                                                                    Fig. 14
1-2 Click       icon as shown if Fig. 11 from the tool bar to bring up
    the "Configuration Setup" windows as shown in Fig. 12.




                                                                                           Fig. 11




                                                                                                     Step 4: Modify DDC data (Monitor Serial No.)

                                                                                                     1.      Click Next till the Step 7 of 9 window appears as shown in Fig. 15.
                                                                                                     2.      Fill out the new Serial No. (for example, TY 500053).
                                                                                                     3.      Click Next till the last step window appears, then click Finish to exit
                                                                                                             the Step window.

2.    Select the DDC2B as the communication channel.
      Select "Enable" & fill out "F0" for Mapped EDID page address
      as shown in Fig. 12.
                                                                                                                                   ----->
                                                                                                                                    ----->




                                                                                                                        a space
                                                                                                                              two space                                            Fig. 15
                                                                                         Fig. 12




                                                                                                     Definition of Serial Number

                                                                                                     TY000028000001

                                                                                                                                            Serial Number (U.S.A: 8 digit)
                                                                                                                                                       (Others regions: 6 digit)
                                                                                                                                            Week
                                                                                                                                            Year

                                                                                                                                            TY Code
                                                                                                                                            TY----Chungli

3.    Click OK button to confirm your selection.                                                                                            CX----Dong Guan
                                                                                                                                            HD----Hungary
                                                                                                                                            BZ----Suzhou


3Back                                                                                                                                                                              Forward4
                                           DDC Instructions (Continued)                                              107B2 CM24 GSIII              13
                                                                                                                           Go to cover page

Step 5: **Configuration Setup & Enter Factory Mode **

1.   Click      icon from the tool bar to bring up the Configuration Setup
     windows again. Then, select "Software DDC only" as shown in Fig.
     16. Click "OK".                                                                                                                         Fig. 19




                                                             Fig. 16         2.    Click Save.

                                                                             Step 9: Load DDC data

                                                                             1.   Click     from the tool bar.
                                                                             2.   Select the file you want to open as shown in Fig. 20.
                                                                             3.   Click Open.
                                                                             4.   Access "Factory Mode" and enable "Software DDC only" as shown
                                                                                  in Fig. 16.
Access factory mode:                                                         5.   Write EDID.
- Turn off monitor (don't turn off PC)
- Press "     " and "        " simultaneously on the front
   control panel, then press "       ",wait till the OSD menu
                                                                                                                                       Fig. 20
   with characters " factory mode (below OSD menu)" come
   on the screen of monitor.

                                   00115



                                                              Fig. 17
                                                                             Step 10: Exit DDC program
                                                                              Pull down the File menu and select Exit as shown in Fig. 21.
                                                                             (EDID Tool 3.01)
                            MODEL SELECT
        Factory          MODEL SELECT
        Mode
        Indicator          GS3 107B2 V1.41 20000630
                                                                                                                                       Fig. 21

Step 6: Write DDC data
1. Click      (Write EDID) icon from the tool bar to write DDC data.
    Bring up "Writing 0%~100%, ready" a progressing bar on the left
    down corner.
2. Click      (Read EDID) to confirm it.
                                                                                  Note1 : In User Mode: Read DDC data only
Step 7: Confirm Serial Number in User Mode                                                Before read EDID code, please confirm that the Software
1. Press the       button to turn off the monitor. Press the  button                      DDC only is disabled as shown in Fig. 22.
    again to turn on the monitor.
2. Press the        button to bring up the OSD Main Menu.
3. Press the        button to select Extra Control, press the  button
    to confirm your selection.
4. Confirm the Serial Number is updated as shown in Fig. 18.                                                                           Fig. 22




                                                              Fig. 18



                          TY 123456                                               Note 2 : In Factory Mode: Read/Write DDC data
                                                                                           Before Read/Write EDID code, please confirm that the
                                                                                           Software DDC only is enabled as shown in Fig. 23.
Step 8: Save DDC data
    Sometimes, you may need to save DDC data as a text file for using
    in other IC chip. To save DDC data, follow the steps below:

1. Click       (Save) icon (or click "file"-> "save as") from the tool bar                                                             Fig. 23
   and give a file name as shown in Fig. 19.
   The file type is EDID301 file (*.ddc) which can be open in WordPad.
   By using WordPad, the texts of DDC data & table (128 bytes, hex
   code) can be modified. If DDC TEXTS & HEX Table are completely
   correct, it can be saved as .ddc flie to re-load it into EEPROM for
   DDC Data application.