 16     109P2 GS3 CM25                Purity and Convergence Adjustments
9 Go to cover page
1. Purity adjustment

    - Make sure the monitor is not exposed to any
      external magnetic field.
   - Produce a full red pattern on the screen, adjust the
     purity magnet rings on the PCM assy (on CRT) to
     obtain a complete field of the color red. This is done
     by moving the two tabs (2-pole) in such a manner
     that they advance in an opposite direction but at
     the same time to obtain the same angle between                                                       2-pole purity magnet
     the two tabs, which should be approximately 180
                                                                                                          6-pole convergence magnet
     degree.
   - Check by full green pattern and full blue pattern
                                                                                                          4-pole convergence magnet
     again to observe their respective color purity.                                                      Deflection Yoke


2. Static convergence

    Introduction                                                   4-pole               Beam motion producced by the
   Slight deviation in the static convergence can be                                    4-pole convergence magnet
   corrected by using two permanent pairs of magnets
   which are fitted around the neck of the CRT. These
   are the 4-pole magnet and the 6-pole magnet.                                                                         S
   The 4-pole magnet move the outermost electron                            S               N
   beams (R and B) parallel in the opposite direction
   from the other. The 6-pole magnet moves the                                  B   G   R                       N   B   G       R   N
   outermost electron beam (R, B and G) parallel in the
   opposite direction from the other.                                       N               S
   The magnetic field of the above magnets do not affect                                                                S
   the center of the CRT neck.
                                                                Beam displacement                   Magnetic flux
    Setting                                                     direction                           lines
   - Before the static convergence setting can be made,
      the monitor must be switched on for 30 minutes.
   - The focus setting must be made correctly.
   - Signal: 640 * 480, 31.5 kHz/60 Hz mode.
   - Set the tabs of the 4-pole magnet in the neutral
     position. This is when the tabs are opposite one              6-pole               Beam motion producced by the
     another. In this position the magnets do not affect the                            6- pole convergence magnet
     deflection of the R and B electron beams.
   - Set the tabs of the 6-pole magnet in the neutral                               N
                                                                                                                    S       N
     position. This is when the tabs are opposite one
     another. In this position the magnets do not affect the           S                        S
     deflection of the R, B, and G electron beams.                              B   G   R                   N       B   G   R       S
   - First set the 4-pole magnet optimally.
   - Then set the 6-pole magnet optimally.                             N                        N
   - If the convergence is not now optimal, then adjust to                                                          S       N
                                                                                    S
     the optimal setting with the 4-pole magnet and then with
     the 6- Pole magnet again.
   - Set the tabs of the 6-pole magnet in the neutral
     position. This is when the tabs are opposite one
     another. In this position the magnets do not affect the
     deflection of the R, B, and G electron beams.
   - First set the 4-pole magnet optimally.
   - Then set the 6-pole magnet optimally.
   - If the convergence is not now optimal, then adjust to
     the optimal setting with the 4-pole magnet and then
     with the 6- pole magnet again.