For internal use only                                                             PHILIPS

                                                            ISSUE SNL2001.02 (01-05-16)
Published by:
Service Department Audio

                     BUSINESS CREATION UNIT AUDIO

      SERVICE NEWSLETTER
02.01 TYPENUMBER(S): ACT7585

      INFORMATION    : Correction to Service Manual
                       CD-drive DA23LN (3103 309 05320) has been used instead of
                       DA23L (3103 309 05340). The new CD-drive requires the following
                       modification for proper detection of the drive version:
                       Add      3418 4822 051 30008            Chip Jumper 0603
                       Delete 3419

      REMARKS        :


02.02 TYPENUMBER(S): ACT7585

      INFORMATION    : Correction to the Service Manual, Partslist
                       Resistor 3869 should be 47 (4822 051 30479).

      REMARKS        :


02.03 TYPENUMBER(S): AZ1018

      INFORMATION    : In course of production, resistor 3452 has been changed from 2.7k
                       to 4.7k (4822 051 30472) to improve "LCD leakage".

      REMARKS        :


02.04 TYPENUMBER(S): AZ1110, AZ1111, AZ1112, AZ1113, AZ1114, AZ1116, AZ1117,
                     AZ1118, AZ1119, AZ8084, AZ8085, AZ8086, AZ8087

      SYMPTOM        :    IRIS CODE 2 1 1 X
                         Set doesn't work with some specific batteries due to inproper battery
                         contact.

      CURE           : The guiding rib in the battery compartment has been modified.

      REMARKS        : Modified parts are used in production with production code
                       KZ010049136XXX from week 0049 onwards.