Service Manuals, User Guides, Schematic Diagrams or docs for : Philips Symptom Cure 2001-02 SymptomCure references pa98-04

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
pa98-04


>> Download pa98-04 documenatation <<

Text preview - extract from the document
For internal use only                                                                   PHILIPS

                                                                 ISSUE PA98.04 (98-07-24)
Published by:
Service Department LOBPA Hong Kong

                 LINE OF BUSINESS PORTABLE AUDIO

      SERVICE NEWSLETTER
04.01 TYPENUMBER(S): AJ3925

     INFORMATION    : Following parts are changed from production start onwards to
                      improve distortion and amplification reserve:

                     Capacitor 2210 and       2213    are   changed   to   4.7nF (4822 126 11714)
                     Resistor 3201 and        3204    are   changed   to   6.8k (4822 116 83961)
                               3202 and       3205    are   changed   to    27k (4822 116 52264)
                               3221 and       3222    are   changed   to    18k (4822 116 52251)

     REMARKS        : Changes are applied to sets of new generation with production code
                      "KT-02" only.


04.02 TYPENUMBER(S): AJ3940

     INFORMATION    : Correction to the Instruction Fof Use:

                     To set WEEKEND SLEEPER, only following steps are necesary:

                     1. Select the alarm you wish to deactivate by pressing the
                        ALM 1 or 2 button. Within 5 seconds the display shows the
                        set alarm time. Briefly press the WEEKEND SLEEPER once.

                         If the weekend sleeper is activated, zz will appear in the display
                         for ALARM 1 or 2.

                     2. To cancel the weekend sleeper function, repeat step 1 until zz
                        no longer appears in the display.

     REMARKS        : Errata sheet will be inserted from week 9831 onwards.
                      The IFU will also be updated.