Service Manuals, User Guides, Schematic Diagrams or docs for : RCA Audio RS2625 rca_rs2625_111

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
rca_rs2625_111


>> Download rca_rs2625_111 documenatation <<

Text preview - extract from the document
SAFETY PRECAUTIONS
DO NOT OPERATE THIS INSTRUMENT OR PERMIT IT TO BE OPER-                                   Do not remove, install, or otherwise handle the picture tube in any manner with-
ATED WITHOUT ALL PROTECTIVE DEVICES INSTALLED AND                                         out first putting on shatterproof goggles equipped with side shields. People not so
FUNCTIONING. SERVICERS WHO DEFEAT SAFETY FEATURES OR                                      equipped must be kept safely away while picture tubes are handled. Keep the
FAIL TO PERFORM SAFETY CHECKS MAY BE LIABLE FOR ANY                                       picture tube away from your body. Do not handle the picture tube by its neck.
RESULTING DAMAGE, AND MAY EXPOSE THEMSELVES AND OTH-                                      Some "in-line" picture tubes are equipped with a permanently attached deflection
ERS TO POSSIBLE INJURY.                                                                   yoke; because of potential hazard, do not try to remove such "permanently at-
READ AND COMPLY WITH ALL CAUTION AND SAFETY-RELATED                                       tached" yokes from the picture tube.
NOTES ON OR INSIDE THE RECEIVER CABINET, AND THE RE-                                      X-RADIATION AND HIGH VOLTAGE LIMITS - Because the picture
CEIVER CHASSIS, OR ON THE PICTURE TUBE.                                                   tube is the primary source of X-radiation in solid-state TV receivers, it is specially
SAFETY GLASSES SHOULD BE USED WHEN SERVICING ELEC-                                        constructed to prohibit X-radiation emissions. For continued X-radiation protec-
TRONIC INSTRUMENTS. INADVERTENTLY OVERSTRESSING COM-                                      tion, a replacement picture tube must be the same type as the original. The picture
PONENTS MAY CAUSE THEM TO SHATTER, DISCHARGING SMALL                                      shields, mounting hardware and lenses (projection TV) may also perform an X-
PARTICLES.                                                                                radiation protection function, and they must be correctly in place. Anode connec-
                                                                                          tors contain an X-radiation shield - use only the manufacturer's specified anode
DESIGN ALTERATION WARNING - Do not alter or add to the mechanical or                      connectors. High voltage must be measured each time servicing that involves
electrical design of this instrument. Design alterations and additions may alter the      power supply, horizontal deflection or high voltage circuits is performed. Correct
safety characteristics of this instrument and create a hazard to the user. Design         operation of the X-radiation circuits must also be confirmed each time these cir-
alterations or additions may void the manufacturer's warranty and may make you,           cuits are serviced (X-radiation circuits may also be called "horizontal disable" or
the servicer, responsible for personal injury or property damage resulting there-         "hold-down" circuits). Read and apply high voltage limits and, if the chassis is so
from.                                                                                     equipped, the X-radiation protection circuit specifications. These limits and speci-
BEFORE RETURNING AN INSTRUMENT TO THE CUSTOMER, always                                    fications are given on instrument labels and are included in this service data. High
make a safety check of the entire instrument, including, but not limited to, the          voltage is maintained within specified limits by close-tolerance safety-related com-
following items:                                                                          ponents (and adjustments) in the high voltage circuit. If high voltage exceeds
FIRE AND SHOCK HAZARD                                                                     specified limits, check each safety related component specified on the schematic
                                                                                          and take corrective action.
  1. Never release a repaired unit unless all protective devices such as insula-
     tors, barriers, covers, strain reliefs and other protective hardware have been       ANTENNA LEAKAGE RESISTANCE CHECK - With the instrument AC
     installed in accordance with the original design.                                    plug removed from the AC source, connect an electrical jumper across the two AC
                                                                                          plug prongs. Place the instrument AC switch (if applicable) in the "on" position.
  2. Be sure that there are no cabinet openings through which an adult or a child         Connect one lead of an ohmmeter to the AC plug prongs and touch the other
     might be able to insert their fingers and contact a hazardous voltage. Such          ohmmeter lead, in turn, to each (exposed) antenna input terminal screw and/or
     openings include, but are not limited to: (a) spacing between picture tube           coaxial connector. If the measured resistance is less than 1.0 Megohm, or greater
     and cabinet mask, (b) excessively wide cabinet ventilation slots, and (c) an         than 5.2 Megohm, an abnormality exists which must be corrected before the in-
     improperly fitted or incorrectly secured back cover or cabinet.                      strument is returned to the customer. Repeat this test with the AC switch in the
  3. Observe original lead dress. Take care to restore leads to their original            "off" position.
     dress. Make sure that leads are not in contact with sharp edges or thermally
     hot parts. Always inspect in all areas for pinched, out-of-place or frayed
     wiring. Do not change spacing between adjacent components, or between                                                                                           reading
     components and printed circuit board. Check the AC power cord for dam-                                                                                         should be
     age.                                                                                                                                                            < 0.5mA
                                                                                                DEVICE                                             LEAKAGE
                                                                                                                probe all
  4. Be certain to remove loose solder balls and all other loose foreign particles.             UNDER                                              CURRENT
                                                                                                                exposed
  5. Check components, parts and/or wiring for physical evidence of damage,                      TEST                                               TESTER
                                                                                                                 metal
     overheating or deterioration, and replace if necessary. Determine the cause                                surfaces                            +    -
     of damage and/or overheating and, if necessary, take corrective action to
     remove any potential safety hazard.
  6. Parts Replacement - Many instruments electrical and mechanical parts have
                                                                                            2-wire
     special safety-related characteristics, some of which are often not evident
                                                                                             cord
     from visual inspection, and the protection they give cannot necessarily be                          also test with
     obtained by replacing them with components rated for higher voltage, watt-                          plug reversed
     age, etc. Parts that have special safety characteristics are identified in this                    (use ac adapter                                                earth
     service data by a ( ) on schematics and in the parts list. Use of a substitute                    plug as required)                                              ground
     replacement that does not have the same safety characteristics as the recom-
     mended replacement part in the service data parts list may create shock, fire        LEAKAGE CURRENT HOT CHECK FOR 2-WIRE OR 3-WIRE
     and/or other hazards. Always consult the appropriate current service litera-         GROUNDED CORD SETS - With the instrument completely reassembled,
     ture for the latest information.                                                     plug the AC line cord into the mains AC outlet at normal line voltage via a non-
  7. Some instruments chassis' normally have 85VAC (RMS) between chassis                  polarized adapter. DO NOT GROUND THE 3RD PRONG OF THE ADAPTER
     and earth ground, regardless of the AC plug polarity. Some instrument                AND DO NOT USE AN ISOLATION TRANSFORMER. Use a leakage current
     chassis' are electrically connected directly to one conductor of the AC power        tester or metering system that complies with American National Standards Insti-
     cord. Some instrument chassis' have a secondary ground system in addition            tute (ANSI) C101.1 Leakage Current for Appliances and with Underwriters Labo-
     to the main chassis ground. This secondary ground system is not isolated             ratories (UL) 1492 (Section 67). With the instrument AC switch first in the "on"
     from the AC power line. The two ground systems are electrically separated            position and then in the "off" position, measure from a known earth ground (metal
     by insulating material that must not be defeated or altered. Thus, when              water pipe, conduit, etc.) to all exposed metal parts of the instrument (antennas,
     servicing any unit always use a separate isolation transformer for the chas-         handle bracket, metal cabinet, screwheads, metallic overlays, control shafts, etc.).
     sis. Failure to use a separate isolation transformer may expose the servicer         Any current measured must not exceed 0.5 milliampere. Reverse the adapter plug
     to possible shock hazard, and may cause damage to servicing instruments.             in the outlet and repeat the test. ANY MEASUREMENTS NOT WITHIN THE
  8. Many electronic products use a polarized AC line cord (one wide pin on the           LIMITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCK HAZ-
     plug). Defeating this safety feature may create a potential hazard to the            ARD THAT MUST BE ELIMINATED BEFORE RETURNING THE IN-
     servicer and the user. Extension cords that do not incorporate the polarizing        STRUMENT TO THE CUSTOMER OR BEFORE CONNECTING THE
     feature should never be used.                                                        ANTENNA OR ACCESSORIES. If a leakage current tester is not available,
                                                                                          connect a 1.5 Kohm, 10 Watt resistor, in parallel with a 0.15 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo