Text preview - extract from the document
                                      Test and
                                      Measurement Division




               Operating Manual



               Digital Radiocommunication
               Tester for DECT
               CMD60
               1050.9008.60




Printed in the Federal
Republic of Germany




1051.5929.12-05-                  1
CMD60                                                                                               Tabbed Divider Overview




Data Sheet

Safety Instructions
Certificate of quality
EC Certificate of Conformity
List of R & S Representatives




1              Preparation for Use ............................................................................. Tabbed Divider 1

2              Manual Operation ................................................................................. Tabbed Divider 2
               Getting Started
               Description of the Menus (Reference Description)


3              Remote Control ..................................................................................... Tabbed Divider 3

4              Maintenance ........................................................................................... Tabbed Divider 4

5              Testing the Rated Specifications................................................... Tabbed Divider 5

Annex A (Interfaces) .............................................................................................. Tabbed Divider 6

Annex B (List of Error Messages) ................................................................... Tabbed Divider 7

Annex C (List of Commands) ............................................................................ Tabbed Divider 8

Annex D (Program Example) ............................................................................. Tabbed Divider 9

Index .......................................................................................................................... Tabbed Divider 10




1051.5929.12                                                            3                                                                    E-4
                                             Safety Instructions
This unit has been designed and tested in accordance with the EC Certificate of Conformity and has left the
manufacturer's plant in a condition fully complying with safety standards.
To maintain this condition and to ensure safe operation, the user must observe all instructions and warnings
given in this operating manual.
1. The unit may be used only in the operating           7. It is not permissible to interrupt the PE conduc-
    conditions and positions specified by the               tor intentionally, neither in the incoming cable
    manufacturer. Unless otherwise agreed, the fol-         nor on the unit itself as this may cause the unit
    lowing applies to R&S products:                         to become electrically hazardous.
    Pollution severity 2, overvoltage category 2, IP        Any extension lines or multiple socket outlets
    degree of protection 2X, altitude max. 2000 m.          used must be checked for compliance with rele-
    The unit may be operated only from supply net-          vant safety standards at regular intervals.
    works fused with max. 16 A.                         8. If the unit has no power switch for disconnection
2. For measurements in circuits with voltages Vrms          from the AC supply, the plug of the connecting
    > 30 V, suitable measures should be taken to            cable is regarded as the disconnecting device.
    avoid any hazards.                                      In such cases it must be ensured that the power
    (using, for example, appropriate measuring              plug is easily reachable and accessible at all
    equipment, fusing, current limiting, electrical         times (length of connecting cable approx. 2 m).
    separation, insulation).                                Functional or electronic switches are not suit-
                                                            able for providing disconnection from the AC
3. If the unit is to be permanently wired, the PE           supply.
    terminal of the unit must first be connected to         If units without power switches are integrated in
    the PE conductor on site before any other con-          racks or systems, a disconnecting device must
    nections are made (installation and cabling of          be provided at system level.
    the unit to be performed only by qualified techni-
    cal personnel).                                     9. Applicable local or national safety regulations
                                                            and rules for the prevention of accidents must
4. For permanently installed units without built-in         be observed in all work performed.
    fuses, circuit breakers or similar protective de-
                                                            Prior to performing any work on the unit or
    vices, the supply circuit must be fused such as
                                                            opening the unit, the latter must be discon-
    to provide suitable protection for the users and
                                                            nected from the supply network.
    equipment.
                                                            Any adjustments, replacements of parts, main-
5. Prior to switching on the unit, it must be ensured       tenance or repair may be carried out only by
    that the nominal voltage set on the unit matches        authorized R&S technical personnel.
    the nominal voltage of the AC supply network.           Only original parts may be used for replacing
    If a different voltage is to be set, the power fuse     parts relevant to safety (eg power switches,
    of the unit may have to be changed accordingly.         power transformers, fuses). A safety test must
6. Units of protection class I with disconnectible          be performed after each replacement of parts
    AC supply cable and appliance connector may             relevant to safety.
    be operated only from a power socket with               (visual inspection, PE conductor test, insulation-
    earthing contact and with the PE conductor con-         resistance, leakage-current measurement, func-
    nected.                                                 tional test).
                                                        10. Any additional safety instructions given in this
                                                            manual are also to be observed.

Safety-related symbols used on equipment and documentation from R&S:




   Observe             Weight        PE terminal   Ground        Danger!          Warning!        Ground
  operating         indication for                 terminal    Shock hazard          High
 instructions        units >18 kg                                               temperatures
                                                                                  Warning!
                                                                                 Hot surfaces




095.1000 Sheet 17
                                                      EC Certificate of Conformity




Certificate No.: 9502035


This is to certify that:


             Equipment type   Order No.                Designation


             CMD60            1050.9008.60             Dig. Radiocommunication Tester


complies with the provisions of the Directive of the Council of the European Union on the
approximation of the laws of the Member States

- relating to electrical equipment for use within defined voltage limits
  (73/23/EEC revised by 93/68/EEC)

- relating to electromagnetic compatibility
  (89/336/EEC revised by 91/263/EEC, 92/31/EEC, 93/68/EEC)

Conformity is proven by compliance with the following standards:

EN61010-1 : 1993 + A2 : 1995
EN50081-1 : 1992
EN50082-1 : 1992

Affixing the EC conformity mark as from 1995



                                                   ROHDE & SCHWARZ GmbH & Co. KG
                                                   M