Text preview - extract from the document
R&S UPL                                                          Previous/Actual Data Comparison


             Supplement to the R&S UPL Manual
The R&S UPL software version 3.02/3.03 has been upgraded to 3.04/3.05.
The modifications in 3.04 and 3.05 are described below.



Brief Overview
GENERATOR panel:

                 Previously ...                                                Now ...

... frequency sweeps were only possible with    ... this error is eliminated.
    an activated equalizer when you selected at
    least three sweep points. With only two         For manual control, see
    sweep points, a wrong output level was set.     2.5.4.1.3 Equalization of SINE, SINE BURST,
                                                    DFD, MULTISINE, RANDOM
                                                    For IEC/IEEEbus command, see
                                                    3.10.1.4.2 Sweep Settings for Gen. SIN, STER,
                                                    BURS, S2P, MDIS,DFD, DC

... in the RANDOM Domain TIME function,             ... this noise generator has been improved in such a
    acoustically interfering periodic artfacts were     way that there is no periodicity anymore.
    audible but irrelevant to measurements.
                                                        For manual control, see
                                                        2.5.4.9 RANDOM
                                                        For IEC/IEEEbus command, see
                                                        3.10.1.5.7 RANDOM

... negative phase parameters were allowed in        ... this error is eliminated.
    the MULTISINUS function but were inter-
    nally limited to 0