SERVICE ADJUSTMENTS                SVP310-320-
350




             SERVICE ADJUSTMENTS




                      93
SERVICE ADJUSTMENTS        SVP310-320-
350




                      94
SERVICE ADJUSTMENTS                                                                                   SVP310-320-
350

                                                SERVICE ADJUSTMENTS




These adjustments must be performed when particular components, as CRT, yoke, etc., have been replaced.




MAGNET ADJUSTMENT
Signal: video composite 15KHz connected to VIDEO 1.
         UPC ON (projector working at 32 KHz).


                                     non-pole




                                             50 mm




CENTERING MAGNETS ADJUSTMENT


?     Adjust CONV/CENT H V to 50
?     UPC ON
?     Rotating the centering magnets align the raster in the center of the tube screen.




2/4 POLE ADJUSTMENT


1.   Select the HATCH COARSE test pattern, using the TEST button on the full function remote control.
2.   Adjust the focus potentiometer of the corresponding CRT completely in anti-clockwise.
3.   Adjust the 2 pole magnet till the flare is equal on both sides of the vertical and horizontal lines (see following figure).




                                                              95
SERVICE ADJUSTMENTS                                                                                 SVP310-320-
350




                           not correct        correct


4.   Select the DOTS test pattern, using the TEST button on the full function remote control.
5.   Adjust the focus potentiometer of the replaced CRT slightly clockwise.
6.   Adjust the 4-pole magnet till the dots have the best circular shape in the center of the screen (see following figure).




                                                  not correct             correct


Note. Repeat the 2-pole and 4-pole magnets alignments if necessary, because they influence each other.


7.   Select the HATCH COARSE test pattern, using the TEST button on the full function remote control.
8.   Adjust the focus till the flare disappear from the lines.


How to adjust the 2/4 pole
                                                                      X




                                                                              Y


X: adjusts the power of magnetic force
Y: adjusts the direction of the magnetic force




                                                                 96
SERVICE ADJUSTMENTS                                                                      SVP310-320-
350

SERVICE MODE


Conditions:
Signal generator: - 15 KHz, grey scale.
Plug a jumper into JP1 position of the JP101 connector placed on the PC157 microboard.
Switch-on the projector by the mains switch, on the screen will appear flashing:


                                            FACTORY SET


Into this mode are possible to carry out the factory adjustments, as the following:




G2 AND WHITE BALANCE ADJUSTMENT.


Press OPT button, will appear:


                  OPTIONS MENU


OSD
INSTALLATION TYPE
POWER ON
VCR STABILITY
MEMORY MANAGER
WORKING TIME
SERVICE MENU




Select SERVICE MENU, press ENTER, will be displayed:


                   SERVICE MENU


CONFIGURATION
G2 ADJUST
IIC                   ON
INPUTS
PEAK LIMIT
CONV 15K/50Hz



                                                            97
SERVICE ADJUSTMENTS                                                                             SVP310-320-
350

Select G2 ADJUST, press ENTER, will be displayed:


                      G2 ADJUST




BLACK            49         49     49
WHITE            49         49     49


In this condition brightness and contras will be automatically fixed at 50.
Connect an oscilloscope probe 100:1 to R481 (cathode) of the PC152 CRT board of the red tube.
Adjust the red G2 potentiometer to have 140 V of the cut-off level.
Repeat the same operations for the green and blue tubes.


Press VID.S, will appear:


VIDEO SETUP


Y/C DELAY
WHITE BALANCE
COMB FILTER
GAMMA ADJ
ADAPTIVE BLACK
BLUE STRETCH




Select WHITE BALANCE, will appear:


WHITE BALANCE


  3200 K         ADJ
? 6500 K         ADJ

  9300 K         ADJ
  USER       ADJ
  FACTORY SET


This menu permits to change the three color temperature sets, preset in Factory, at 3200