                 COLOR MONITOR
                 SyncMaster 800TFT
                 (Toshiba Panel)




SERVICE                  Manual

 COLOR MONITOR                          CONTENTS
                       1. Precautions

                       2. Product Specifications

                       3. Disassembly & Reassembly

                       4. Alignments & Adjustments

                       5. Troubleshooting

                       6. Exploded View & Parts List

                       7. Electrical Parts List

                       8. Block Diagram

                       9. Wiring Diagram

                       10. Schematic Diagrams
1 Precautions
Follow these safety, servicing and ESD precautions to prevent damage and to protect against potential hazards such as
electrical shock.

1-1 Safety Precautions

1-1-1 Warnings
1.   For continued safety, do not attempt to modify the                                                (READING SHOULD
     circuit board.                                                                                   NOT BE ABOVE 0.5mA)


2.   Disconnect the AC power and DC power jack
     before servicing.                                                     DEVICE
                                                                                                            LEAKAGE
                                                                                                            CURRENT
                                                                           UNDER                             TESTER
1-1-2 Servicing the LCD Monitor                                            TEST
                                                                                         TEST ALL
                                                                                      EXPOSED METAL
1.   When servicing the LCD Monitor, Disconnect the                                     SURFACES


     AC line cord from the AC outlet.
                                                                                2-WIRE CORD

2.   It is essential that service technicians have an
     accurate voltage meter available at all times. Check
     the calibration of this meter periodically.                               *ALSO TEST WITH
                                                                               PLUG REVERSED
                                                                             (USING AC ADAPTER
                                                                             PLUG AS REQUIRED)                     EARTH
1-1-3 Fire and Shock Hazard                                                                                       GROUND



Before returning the monitor to the user, perform the                   Figure 1-1. Leakage Current Test Circuit
following safety checks:
1.   Inspect each lead dress to make certain that the         4.   With the unit completely reassembled, plug the AC
     leads are not pinched or that hardware is not                 line cord directly into a 120V AC outlet. With the
     lodged between the chassis and other metal parts in           unit's AC switch first in the ON position and then
     the monitor.                                                  OFF, measure the current between a known earth
2.   Inspect all protective devices such as nonmetallic            ground (metal water pipe, conduit, etc.) and all
     control knobs; insulating materials; cabinet backs;           exposed metal parts, including: metal cabinets,
     adjustment and compartment covers or shields;                 screwheads and control shafts. The current
     isolation resistor-capacitor networks; mechanical             measured should not exceed 0.5 milliamp. Reverse
     insulators, etc.                                              the power-plug prongs in the AC outlet and repeat
3.   Leakage Current Hot Check (Figure 1-1): WARNING:              the test.
     Do not use an isolation transformer during this test.
     Use a leakage current tester or a metering system        1-1-4 Product Safety Notices
     that complies with American National Standards
                                                              Some electrical and mechanical parts have special
     Institute (ANSI C101.1, Leakage Current for
                                                              safety-related characteristics which are often not
     Appliances), and Underwriters Laboratories (UL           evident from visual inspection. The protection they give
     Publication UL1410, 59.7).                               may not be obtained by replacing them with
                                                              components rated for higher voltage, wattage, etc. Parts
                                                              that have special safety characteristics are identified by
                                                                ! on schematics and parts lists. A substitute
                                                              replacement that does not have the same safety
                                                              characteristics as the recommended replacement part
                                                              may create shock, fire and / or other hazards. Product
                                                              safety is under review continuously and new
                                                              instructions are issued whenever appropriate.




SyncMaster 800TFT                                                                                                           1-1
1 Precautions

1-2 Servicing Precautions
WARNING:          An electrolytic capacitor installed with the wrong polarity may explode.
Caution:          Before servicing units covered by this service manual, read and follow the Safety Precautions
                  section of this manual.
Note:             If unforeseen circumstances create conflict between the following servicing precautions and any of the
                  safety precautions, always follow the safety precautions.


1-2-1 General Servicing Precautions
1.    Always unplug the unit's AC power cord from the             4.   Check the insulation between the blades of the AC
      AC power source and disconnect the DC power                      plug and accessible conductive parts (examples:
      jack before attempting to:                                       metal panels, input terminals and earphone jacks).
      (a) remove or reinstall any component or assembly.          5.   Insulation Checking Procedure: Disconnect the
      (b) disconnect PCB plugs or connectors.                          power cord from the AC source and turn the power
      (c) connect a test component in parallel with an                 switch ON. Connect an insulation resistance meter
      electrolytic capacitor.                                          (500 V) to the blades of the AC plug.
2.    Some components are raised above the printed                     The insulation resistance between each blade of the
      circuit board for safety. An insulation tube or tape             AC plug and accessible conductive parts (see
      is sometimes used. The internal wiring is                        above) should be greater than 1 megohm.
      sometimes clamped to prevent contact with
                                                                  6.   Always connect a test instrument's ground lead to
      thermally hot components. Reinstall all such
                                                                       the instrument chassis ground before connecting the
      elements to their original position.
                                                                       positive lead; always remove the instrument's
3.    After servicing, always check that the screws,                   ground lead last.
      components and wiring have been correctly
      reinstalled. Make sure that the area around the
      serviced part has not been damaged.



1-3 Electrostatically Sensitive Devices (ESD) Precautions
Some semiconductor (solid state) devices can be easily damaged by static electricity. Such components are commonly
called Electrostatically Sensitive Devices (ESD). Examples of typical ESD components are integrated circuits and some
field-effect transistors. The following techniques will reduce the incidence of component damage caused by static
electricity.
1. Immediately before handling any semiconductor
     components or assemblies, drain the electrostatic            6. Do not remove a replacement ESD from its
     charge from your body by touching a known earth                   protective package until you are ready to install it.
     ground. Alternatively, wear a discharging wrist-                  Most replacement ESDs are packaged with leads
     strap device. To avoid a shock hazard, be sure to                 that are electrically shorted together by conductive
     remove the wrist strap before applying power to                   foam, aluminum foil or other conductive materials.
     the monitor.                                                 7. Immediately before removing the protective
2. After removing an ESD-equipped assembly, place it                   material from the leads of a replacement ESD,
     on a conductive surface such as aluminum foil to                  touch the protective material to the chassis or
     prevent accumulation of an electrostatic charge.                  circuit assembly into which the device will be
                                                                       installed.
3. Do not use freon-propelled chemicals. These can
     generate electrical charges sufficient to damage                  Caution: Be sure no power is applied to the
     ESDs.                                                                         chassis or circuit and observe all
4.    Use only a grounded-tip soldering iron to solder or                        other safety precautions.
      desolder ESDs.
                                                                  8.   Minimize body motions when handling
5.    Use only an anti-static solder removal device. Some              unpackaged replacement ESDs. Motions such as
      solder removal devices not classified as "anti-static"           brushing clothes together, or lifting your foot from
      can generate electrical charges sufficient to damage             a carpeted floor can generate enough static
      ESDs.                                                            electricity to damage an ESD.




1-2                                                                                                       SyncMaster 800TFT
2 Product Specifications
2-1 Specifications
                Item                                                         Description

  LCD Panel                       TFT-LCD panel, RGB vertical stripe, normally white transmissive,
                                  18-Inch viewable, 0.28 mm pixel pitch

  Scanning Frequency              Horizontal : 30 kHz to 81 kHz (Automatic)
                                  Vertical : 56 Hz to 85 Hz (~XGA), 76 Hz (SXGA)

  Display Colors                  16.7 Million colors

  Maximum Resolution              Horizontal : 1280 Pixels @ 81 kHz
                                  Vertical : 1024 Pixels @ 76 Hz

  Input Video Signal              Analog, 0.714 Vp-p 