                                                  CONFIDENTIAL
                   TFT-LCD MONITOR
                   GH19P*




SERVICE                  Manual
 TFT-LCD MONITOR                        CONTENTS
                       1. Precautions

                       2. Product Specifications

                       3. Disassembly & Reassembly

                       4. Troubleshooting

                       5. Exploded View & Parts List

                       6. Electrical Parts List

                       7. Block Diagram

                       8. Wiring Diagram

                       9. Schematic Diagrams

                       10. Panel Description
                                                                                                 CONFIDENTIAL
1 Precautions
Follow these safety, servicing and ESD precautions to prevent damage and to protect against potential hazards such as
electrical shock.

1-1 Safety Precautions

1-1-1 Warnings
1.   For continued safety, do not attempt to modify the                                                (READING SHOULD
     circuit board.                                                                                   NOT BE ABOVE 0.5mA)


2.   Disconnect the AC power and DC Power Jack
     before servicing.                                                     DEVICE
                                                                                                            LEAKAGE
                                                                                                            CURRENT
                                                                           UNDER                             TESTER
3.   When the chassis is operating, semiconductor                          TEST
                                                                                         TEST ALL
     heatsinks are potential shock hazards.                                           EXPOSED METAL
                                                                                        SURFACES


1-1-2 Servicing the LCD Monitor                                                 2-WIRE CORD


1.   When servicing the LCD Monitor, remove the static
     charge by connecting a 10k ohm resistor in series                         ALSO TEST WITH
                                                                               PLUG REVERSED
     with an insulated wire (such as a test probe)                           (USING AC ADAPTER
                                                                             PLUG AS REQUIRED)
     between the chassis and the anode lead.                                                                       EARTH
                                                                                                                  GROUND

     (Disconnect the AC line cord from the AC outlet.)
2.   It is essential that service technicians have an                   Figure 1-1. Leakage Current Test Circuit
     accurate voltage meter available at all times. Check
     the calibration of this meter periodically.              4.   With the unit completely reassembled, plug the AC
                                                                   line cord directly into a 120V AC outlet. With the
1-1-3 Fire and Shock Hazard                                        unit's AC switch first in the ON position and then
Before returning the monitor to the user, perform the              OFF, measure the current between a known earth
following safety checks:                                           ground (metal water pipe, conduit, etc.) and all
                                                                   exposed metal parts, including: metal cabinets,
1.   Inspect each lead dress to make certain that the
                                                                   screwheads and control shafts. The current
     leads are not pinched or that hardware is not
                                                                   measured should not exceed 0.5 milliamp. Reverse
     lodged between the chassis and other metal parts in
                                                                   the power-plug prongs in the AC outlet and repeat
     the monitor.
                                                                   the test.
2.   Inspect all protective devices such as nonmetallic
     control knobs, insulating materials, cabinet backs,
     adjustment and compartment covers or shields,            1-1-4 Product Safety Notices
     isolation resistor-capacitor networks, mechanical
                                                              Some electrical and mechanical parts have special
     insulators, etc.
                                                              safety-related characteristics which are often not
3.   Leakage Current Hot Check (Figure 1-1):                  evident from visual inspection. The protection they give
     WARNING: Do not use an isolation transformer             may not be obtained by replacing them with
     during this test.                                        components rated for higher voltage, wattage, etc. Parts
     Use a leakage current tester or a metering system        that have special safety characteristics are identified by
     that complies with American National Standards             ! on schematics and parts lists. A substitute
     Institute (ANSI C101.1, Leakage Current for              replacement that does not have the same safety
                                                              characteristics as the recommended replacement part
     Appliances), and Underwriters Laboratories (UL
                                                              might create shock, fire and / or other hazards. Product
     Publication UL1410, 59.7).
                                                              safety is under review continuously and new
                                                              instructions are issued whenever appropriate.




GH19P*                                                                                                                      1-1
                                                                                                             CONFIDENTIAL
2 Product Specifications
2-1 Specifications


              Item                                                              Description

LCD Panel                       TFT-LCD panel, RGB vertical stripe, normally black transmissive,
                                0.264 pixel pitch

Scanning Frequency              Horizontal : 30 kHz ~ 81 kHz (Automatic)
                                Vertical : 56 Hz ~ 85 Hz

Display Colors                  16,7 Million colors

Maximum Resolution              Horizontal : 1280 Pixels @ 81 kHz
                                Vertical : 1024 Pixels @ 76 Hz

Input Video Signal              Analog : 0.7 Vp-p 