                 COLOR MONITOR
                 CF21M*




SERVICE                Manual

 COLOR MONITOR                        CONTENTS
                     1. Precautions

                     2. Product Specifications

                     3. Disassembly & Reassembly

                     4. Alignment & Adjustments

                     5. Troubleshooting

                     6. Exploded View & Parts List

                     7. Electrical Parts List

                     8. Block Diagram

                     9. Wiring Diagram

                     10. Schematic Diagrams
1 Precautions
1-1 Safety Precautions
WARNINGS                                                     2.   Inspect all protective devices such as nonmetallic
1. For continued safety, do not attempt to modify the             control knobs, insulating materials, cabinet backs,
   circuit board.                                                 adjustment and compartment covers or shields,
2.   Disconnect the AC power before servicing.                    isolation resistor-capacitor networks, mechanical
                                                                  insulators, etc.
3.   When the chassis is operating, semiconductor
     heatsinks are potential shock hazards.                  3.   Leakage Current Hot Check (Figure 1-1):
                                                                  WARNING: Do not use an isolation transformer during
1-1-1    Servicing the High Voltage and CRT :                                 this test.
WARNING:A high voltage VR replaced in the wrong                   Use a leakage current tester or a metering system
        direction may cause excessive X-ray                       that complies with American National Standards
        emissions.                                                Institute (ANSI C101.1, Leakage Current for
1.   When servicing the high voltage system, remove               Appliances), and Underwriters Laboratories (UL
     the static charge by connecting a 10 kohm resistor           Publication UL1410, 59.7).
     in series with an insulated wire (such as a test        4.   With the unit completely reassembled, plug the AC
     probe) between the chassis and the anode lead.               line cord directly into a 120V AC outlet. With the
2.   When troubleshooting a monitor with excessively              unit's AC switch first in the ON position and then
     HV, avoid being unnecessarily close to the monitor.          OFF, measure the current between a known earth
     Do not operate the monitor for longer than is                ground (metal water pipe, conduit, etc.) and all
     necessary to locate the cause of excessive voltage.          exposed metal parts, including: metal cabinets,
                                                                  screwheads and control shafts. The current
3.   High voltage should always be kept at the rated              measured should not exceed 0.5 milliamp. Reverse
     value, no higher. Only when high voltage is                  the power-plug prongs in the AC outlet and repeat
     excessive are X-rays capable of penetrating the shell        the test.
     of the CRT, including the lead in glass material.
     Operation at high voltages may also cause failure of                                              (READING SHOULD
                                                                                                      NOT BE ABOVE 0.5mA)
     the CRT or high voltage circuitry.
4.   When the HV regulator is operating properly, there
                                                                                                            LEAKAGE
     is no possibility of an X-ray problem. Make sure the                 DEVICE
                                                                          UNDER
                                                                                                            CURRENT
                                                                                                             TESTER
     HV does not exceed its specified value and that it is                TEST

                                                                                         TEST ALL
     regulating correctly.                                                            EXPOSED METAL
                                                                                        SURFACES

5.   The CRT is especially designed to prohibit
     X-ray emissions. To ensure continued X-ray                                 2-WIRE CORD

     protection, replace the CRT only with one that is
     the same or equivalent type as the original.                              ALSO TEST WITH
                                                                               PLUG REVERSED
6.   Handle the CRT only when wearing shatterproof                           (USING AC ADAPTER
                                                                             PLUG AS REQUIRED)
     goggles and after completely discharging the high                                                             EARTH
                                                                                                                  GROUND

     voltage anode.
7.   Do not lift the CRT by the neck.                                   Figure 1-1. Leakage Current Test Circuit

1-1-2    Fire and Shock Hazard :                             1-1-3 Product Safety Notices
Before returning the monitor to the user, perform the        Some electrical and mechanical parts have special
following safety checks:                                     safety-related characteristics which are often not
                                                             evident from visual inspection. The protection they give
1.   Inspect each lead dress to make certain that the
                                                             may not be obtained by replacing them with
     leads are not pinched or that hardware is not
                                                             components rated for higher voltage, wattage, etc. Parts
     lodged between the chassis and other metal parts in
                                                             that have special safety characteristics are identified by
     the monitor.
                                                               ! on schematics and parts lists. A substitute
                                                             replacement that does not have the same safety
                                                             characteristics as the recommended replacement part
                                                             might create shock, fire and / or other hazards. Product
                                                             safety is under review continuously and new
                                                             instructions are issued whenever appropriate.
                                                             Components identified by        on schematics and parts
                                                             lists must be sealed by a soldering iron after
                                                             replacement and adjustment.



CF21M*                                                                                                                      1-1
2 Product Specifications
2-1 Specifications

             Item                                                            Description

 Picture Tube:                   21-Inch (53 cm): 20-inch (50.8 cm) viewable, 21": 0.25 mm Dot pitch.
                                 Full-square tube / Perfect Flatmess, 90