Service Manuals, User Guides, Schematic Diagrams or docs for : Sony Ericsson Mobile Phones Сотовый телефон Sony Ericsson V800 GONO GO TEST SCRIPT FOR ANTENNA COUPLER USE

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
GONO GO TEST SCRIPT FOR ANTENNA COUPLER USE


>> Download GONO GO TEST SCRIPT FOR ANTENNA COUPLER USE documenatation <<

Text preview - extract from the document
                                                                                               Go/No Go Test Script Specification, HVC




                Go/No Go Test Script Specification, HVC
                Applicable for V800/V802SE
                Applicable for K700i


                Contents
                1     General.............................................................................................................................2
                      1.1      About this document..........................................................................................2
                      1.2      Requirements.....................................................................................................2
                      1.3      General definitions ............................................................................................4
                      1.4      Test conditions...................................................................................................5
                      1.5      Scripts ................................................................................................................5
                2     Test sequence GSM.........................................................................................................6
                      2.1      INITIALISING and call setup...........................................................................6
                      2.2      Measurement group ALLMEAS HCH 1900.....................................................7
                      2.3      Measurement group ALLMEAS MCH 1900 ....................................................7
                      2.4      Measurement group ALLMEAS LCH 1900 .....................................................8
                      2.5      Measurement group ALLMEAS LCH 1800 .....................................................8
                      2.6      Measurement group ALLMEAS MCH 1800 ....................................................9
                      2.7      Measurement group ALLMEAS HCH 1800.....................................................9
                      2.8      Measurement group ALLMEAS HCH 900.....................................................10
                      2.9      Measurement group ALLMEAS LCH 900 .....................................................10
                      2.10     Measurement group ALLMEAS MCH 900 ....................................................11
                      2.11     Call Termination..............................................................................................11
                3     Test sequence WCDMA ...............................................................................................12
                      3.1      Procedure proposal ..........................................................................................12
                      3.2      Sequence in Instrument Script/MMI proposal.................................................12
                      3.3      Measurement group WCDMA ........................................................................13
                4     Attenuation factors for Sony Ericsson V802SE .........................................................14
                      4.1      Attenuation factors for Rohde&Schwarz antenna coupler use........................14
                      4.2      Attenuation factors for RF-holder use .............................................................15
                5     Revision history.............................................................................................................16




2/1524-2/FEA 209 544/83 B                                                                        Approved according to 000 21-LXE 107 42/1
 Sony Ericsson Mobile Communications AB
                                                                          Go/No Go Test Script Specification, HVC




1 General

      1.1        About this document

                 This document contains the test requirements for theWCDMA/Triband GSM (E-GSM900,
                 GSM1800, GSM1900) pocket transceiver using antenna coupler or direct line connection.
                 This test should be used as an arrival and verification test radio functionality.
                 Tests are done in signalling mode, i.e a call has been established to the test instrument. The
                 testinstrument controls the transceiver unit. RF Performance is measured with an antenna
                 coupler or direct line connection, whichever method is selected.



      1.2        Requirements

                 1. The test should be designed so those users with little or no system expertise can perform
                    accurate testing.


                 2. The measurements should run automatically, though a certain amount of manual work is
                    included (and mandatory), such as call setup (i.e. dialling number).


                 3. It should be possible to print or store the measurement results.

                 4. It should be possible to change the channels used in testing due to possible local radio
                    interference. The range for these settings is specified under 1.3.1General definitions.


                 5. All functions and should be protected in such a manner that the end-user cannot directly
                    change them. (For example, a password or encrypted settings file.)


                 6. The attenuation factors that should be used are stated in section 5. The test instrument
                    must be capable of using different attenuation factors for RX and TX. It must also be
                    possible to use various attenuation factors for different channels in each band.




2/1524-2/FEA 209 544/83 B                                                                                         2(16)
 Sony Ericsson Mobile Communications AB
                                                                       Go/No Go Test Script Specification, HVC



                        Parameter:                     Possible to change:
                        Attenuation factors            Yes *
                        Channel allocations table      Yes, within specified range *
                        Powerlevel allocation table    No
                        Measurement flow               No
                        Measurement limits             No

                        * All functions and settings should be protected in such manner that the end-user
                        cannot directly change them. (For example a password or an encrypted settings file.)

                        Note! Any setups other than the one stated in this document must be discussed
                        and exempted by SonyEricsson to be approved.




2/1524-2/FEA 209 544/83 B                                                                                      3(16)
 Sony Ericsson Mobile Communications AB
                                                                        Go/No Go Test Script Specification, HVC




      1.3        General definitions


      1.3.1      Channel allocation table


                                    Band            Ch definition Any ARFCN of:
                                  E-GSM900              Low          975-979
                                  E-GSM900              Mid           34-38
                                  E-GSM900             High          120-124

                                   GSM1800              Low           512-516
                                   GSM1800              Mid           698-702
                                   GSM1800              High          881-885

                                   GSM1900              Low           512-516
                                   GSM1900              Mid           658-662
                                   GSM1900              High          806-810

                                   WCDMA                Low            10562
                                   WCDMA                Mid            10700
                                   WCDMA                High           10838



      1.3.2      Power level allocation table GSM


                                     Band            PL definition Powerlevel (PL)
                                   E-GSM900              Low             19
                                   E-GSM900              Mid             12
                                   E-GSM900             High             5

                                 GSM1800/1900           Low              15
                                 GSM1800/1900           Mid               8
                                 GSM1800/1900           High             0



      1.3.3      Test limits
                 The test limits for each measurement is specified in the Sequence tables.
                 1. Since the coupler introduces higher measurement inaccuracy, some measurements may
                    have wider limits than stated in the GSM specifications.
                 2. The direct line connection limits conform to the phase 2 GSM specification and the 3GPP
                    specifications.


2/1524-2/FEA 209 544/83 B                                                                                     4(16)
 Sony Ericsson Mobile Communications AB
                                                                           Go/No Go Test Script Specification, HVC

      1.4        Test conditions

      1.4.1      General



                 Attenuation factors


                 The different scripts must be configured with the correct attenuation factors and named after
                 the product that it is designed to test. The attenuation factors to be used are stated in chapter
                 4.



      1.5        Scripts
                 General scripts for the different system/system combinations may be developed. No handover
                 is necessary if not stated, however, SonyEricsson mobile phones are capable with handover
                 between E-GSM900/1800 and might therefore be used in order to decrease test time. Possible
                 system/system combinations are listed below:


      1.5.1      Script types
                 WCDMA
                 E-GSM900
                 GSM1800
                 GSM1900
                 E-GSM900/GSM1800
                 WCDMA/E-GSM900/GSM1800/GSM1900




2/1524-2/FEA 209 544/83 B                                                                                            5(16)
 Sony Ericsson Mobile Communications AB
                                                                         Go/No Go Test Script Specification, HVC


2 Test sequence GSM

      2.1        INITIALISING and call setup

                                                   Parameter                    Value            Unit
                                 BCCH                                            Mid              Ch
                                 TCH                                            Low               Ch
                                 TX power level                                 High              PL
                                 RF output power                                 -50             dBm
                                 System                                       GSM 1900



      2.1.1      Sequence
                 1. Initialise instrument
                 2. Insert a test-USIM and a fully charged standard battery. It's very important that a fully
                    charged battery is used otherwise there is a risk for wrong test results. Position the phone
                    in the coupler according to the pictures. (Fig.1 or Fig.2) An antenna adapter and RF-
                    holder together with RF-cable can also be used for Go/No-Go test. If RF-Holder solution
                    is chosen a dummy battery according to the equipment list shall be used instead of
                    original battery. (Fig.3 and 3.1)




                              Fig.1 Position of the phone in to
                              the Rohde&Schwarz holder




                            Fig.2 Press the antenna connector        Fig.2.1 Slide the holder towards
                            gently against the external antenna      the RF-connector until the adapter
                            connector.                               is in place.



2/1524-2/FEA 209 544/83 B                                                                                      6(16)
 Sony Ericsson Mobile Communications AB
                                                                          Go/No Go Test Script Specification, HVC



                 1. Set up a call to the instrument or let the test instrument call MS.
                 2. Close the lid on the shielding box if that one is used.




      2.2        Measurement group ALLMEAS HCH 1900

                                                  Parameter                      Value            Unit
                                BCCH                                              Mid              Ch
                                TCH                                              High              Ch
                                TX power level                                    Mid              PL
                                RF output power                                   -75             dBm
                                System                                         GSM 1900

      2.2.1      Sequence


                                        Measurement                      Test limits                Unit
                                Power time template                         P/F
                                TX power                                   +/- 5                     dB
                                RMS Phase error                            0



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo