Service Manuals, User Guides, Schematic Diagrams or docs for : Sony Ericsson Mobile Phones Сотовый телефон Sony Ericsson W760 SONY ERICSSON W760 GO NO GO Test Spec

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
SONY ERICSSON W760 GO NO GO Test Spec


>> Download SONY ERICSSON W760 GO NO GO Test Spec documenatation <<

Text preview - extract from the document
                                                                                               Go/No Go Test Script Specification, Electrical




                   Go/No Go Test Script Specification,
                   Electrical
                   Applicable for:W760 and W760c
                   Contents
                   1 ... General................................................................................................................................3
                           1.1      About This Document.....................................................................................3
                           1.2      Script Requirements.......................................................................................3
                           1.3      Traffic Channel (TCH) Allocation Table.......................................................4
                           1.4      Power Level Allocation Table........................................................................4
                           1.5      Test Limits........................................................................................................5
                           1.6      Attenuation Factors.........................................................................................5
                   2 ... Test Sequence - Radiated..............................................................................................5
                           2.1      Initializing and Call Setup...............................................................................5
                           2.2      Audio Loopback...............................................................................................7
                           2.3      GSM 850 Low TCH Measurements .............................................................7
                           2.4      GSM 850 Mid TCH Measurements..............................................................7
                           2.5      GSM 850 High TCH Measurements ............................................................8
                           2.6      GSM 1900 Low TCH Measurements...........................................................8
                           2.7      GSM 1900 Mid TCH Measurements............................................................9
                           2.8      GSM 1900 High TCH Measurements..........................................................9
                           2.9      GSM 1800 Low TCH Measurements.........................................................10
                           2.10     GSM 1800 Mid TCH Measurements..........................................................10
                           2.11     GSM 1800 High TCH Measurements........................................................11
                           2.12     GSM 900 Low TCH Measurements...........................................................11
                           2.13     GSM 900 Mid TCH Measurements............................................................12
                           2.14     GSM 900 High TCH Measurements ..........................................................12
                           2.15     UMTS 850 Low TCH Measurements (W760 only)..................................13
                           2.16     UMTS 850 Mid TCH Measurements (W760 only)...................................13
                           2.17     UMTS 850 High TCH Measurements(W760 only)...................................14
                           2.18     UMTS 1900 Low TCH Measurements (W760 only)................................14
                           2.19     UMTS 1900 Mid TCH Measurements (W760 only).................................15
                           2.20     UMTS 1900 High TCH Measurements (W760 only)...............................15
                           2.21     UMTS 2100 Low TCH Measurements (W760 only)................................16
                           2.22     UMTS 2100 Mid TCH Measurements (W760 only).................................16
                           2.23     UMTS 2100 High TCH Measurements (W760 only)...............................17
                   3 ... Test Sequence - Conducted........................................................................................18
                           3.1      Initializing and Call Setup.............................................................................18
                           3.2      Audio Loopback.............................................................................................19
                           3.3      GSM 850 Low TCH Measurements...........................................................19
                           3.4      GSM 850 Mid TCH Measurements ............................................................19
                           3.5      GSM 850 High TCH Measurements ..........................................................20
                           3.6      GSM 1900 Low TCH Measurements.........................................................20
1211-1568 4
Company Internal      Sony Ericsson Mobile Communications AB
                                                                                           Go/No Go Test Script Specification, Electrical

                           3.7     GSM 1900 Mid TCH Measurements..........................................................21
                           3.8     GSM 1900 High TCH Measurements........................................................21
                           3.9     GSM 1800 Low TCH Measurements.........................................................22
                           3.10    GSM 1800 Mid TCH Measurements..........................................................22
                           3.11    GSM 1800 High TCH Measurements........................................................23
                           3.12    GSM 900 Low TCH Measurements...........................................................23
                           3.13    GSM 900 Mid TCH Measurements............................................................24
                           3.14    GSM 900 High TCH Measurements ..........................................................24
                           3.15    UMTS 850 Low TCH Measurements (W760 only)..................................25
                           3.16    UMTS 850 Mid TCH Measurements (W760 only)...................................25
                           3.17    UMTS 850 High TCH Measurements (W760 only)..................................26
                           3.18    UMTS 1900 Low TCH Measurements (W760 only)................................26
                           3.19    UMTS 1900 Mid TCH Measurements (W760 only).................................27
                           3.20    UMTS 1900 High TCH Measurements (W760 only)...............................27
                           3.21    UMTS 2100 Low TCH Measurements (W760 only)................................28
                           3.22    UMTS 2100 Mid TCH Measurements (W760 only).................................28
                           3.23    UMTS 2100 High TCH Measurements (W760 only)...............................29
                   4 ... Attenuation Factors.......................................................................................................30
                           4.1     Radiated Loss Values for W760 (AT&T and Rogers)..............................30
                           4.2     Radiated Loss Values for W760.................................................................31
                           4.3     Radiated Loss Values for W760c...............................................................32
                           4.4     Conducted Loss Values for W760..............................................................33
                           4.5     Conducted Loss Values for W760c............................................................33
                   5 ... Revision history .............................................................................................................34




1211-1568 4                                                                                                                                          2(34)
Company Internal     Sony Ericsson Mobile Communications AB
                                                                  Go/No Go Test Script Specification, Electrical




1 General

      1.1     About This Document
                   This document contains the test requirements for a 3G GSM (850/900/1800/1900) and
                   UMTS (850/1900/2100) pocket transceiver using an antenna coupler (Radiated) or RF
                   cable (Conducted) connection. These test sequences should be used as an arrival and
                   verification test of radio functionality.
                   Tests are done in signaling mode, i.e. a call has been established to the test instrument.
                   The test instrument controls the transceiver unit. RF performance is measured with an
                   antenna coupler or the direct line connection, whichever method is selected.



      1.2     Script Requirements
                         The test should be designed so those users with little or no system expertise can
                         perform accurate testing.

                         The measurements should run automatically, though a certain amount of manual
                         work is included (and mandatory), such as MS call setup (i.e. dialling number).

                         It should be possible to print or store the measurement results.

                         It should be possible to change the channels used in testing due to possible local
                         radio interference. The ranges for these settings are specified under the Channel
                         Allocation Table.

                         All functions and settings should be protected in such a manner that the end-user
                         cannot directly change them. (For example, a password or encrypted settings file.)

                         The attenuation factors that should be used are stated in section 4. The test
                         instrument must be capable of using different attenuation factors for RX and TX. It
                         must also be possible to use various attenuation factors for different channels in
                         each band.




                   NOTE!        Any setups other than the one stated in this document must be
                                discussed and exempted by Sony Ericsson to be approved.




1211-1568 4                                                                                                    3(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                                   Go/No Go Test Script Specification, Electrical

      1.3     Traffic Channel (TCH) Allocation Table
                                   Band           Ch definition Any ARFCN of:
                                  GSM 850             Low          128-132
                                  GSM 850             Mid          187-191
                                  GSM 850            High          247-251

                                  GSM 900             Low            975-979
                                  GSM 900             Mid             36-40
                                  GSM 900             High           120-124

                                 GSM 1800             Low            512-516
                                 GSM 1800             Mid            697-701
                                 GSM 1800             High           881-885

                                 GSM 1900             Low            512-516
                                 GSM 1900             Mid            658-662
                                 GSM 1900             High           806-810

                                WCDMA 850             Low             4132
                                WCDMA 850             Mid             4175
                                WCDMA 850             High            4233

                               WCDMA 1900             Low             9262
                               WCDMA 1900             Mid             9400
                               WCDMA 1900             High            9538

                               WCDMA 2100             Low             9612
                               WCDMA 2100             Mid             9750
                               WCDMA 2100             High            9888



      1.4     Power Level Allocation Table
                                    Band               PL        Power level (PL)
                                                    definition
                                  GSM 850            Lowest             19
                                  GSM 850              Mid              12
                                  GSM 850            Highest            7

                                  GSM 900            Lowest             19
                                  GSM 900              Mid              12
                                  GSM 900            Highest            5

                               GSM 1800/1900         Lowest             15
                               GSM 1800/1900           Mid              8
                               GSM 1800/1900         Highest            0

1211-1568 4                                                                                                     4(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                 Go/No Go Test Script Specification, Electrical

      1.5     Test Limits
                   The test limits for each measurement are specified in the Sequence Tables.
                            1. Since a coupler introduces higher measurement inaccuracy, some
                               measurements in the radiated test sequences may have wider limits than
                               stated in the 3GPP specifications.
                            2. The conducted limits conform to the phase 3GPP specification.


      1.6     Attenuation Factors
                   The different scripts must be configured with the correct attenuation factors and named
                   after the product that they are designed to test. The attenuation factors to be used are
                   stated in section 4.




2 Test Sequence - Radiated

      2.1     Initializing and Call Setup
                                               Parameter                    Value              Unit
                                BCCH                                         Mid                Ch
                                TCH                                          Mid                Ch
                                TX power level                              High                PL
                                RF output power                              -40               dBm
                                System                                     GSM 850




1211-1568 4                                                                                                   5(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                                 Go/No Go Test Script Specification, Electrical


      2.1.1        Sequence

                            1. Initialize instrument.

                            2. Insert a test-USIM and attach a fully charged standard battery to the
                               mobile. It's very important that a fully charged battery is used otherwise
                               there is a high risk for incorrect test results.

                            3. Position the mobile in the coupler according to the picture.




                               Rohde & Schwarz Shield Box and Coupler (N25)



                            4. Turn on the mobile and wait for registration.

                            5. Set up a call to the instrument or let the instrument call the MS.

                            6. Close the lid on the shielding box.



1211-1568 4                                                                                                   6(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                               Go/No Go Test Script Specification, Electrical



      2.2     Audio Loopback
                            1. Set power level to high.
                            2. Activate audio loopback in the instrument.
                            3. Operator must acknowledge passed or failed before the test is continued.


      2.3     GSM 850 Low TCH Measurements
                                               Parameter                  Value              Unit
                                TCH                                        Low                Ch
                                TX power level                            High                PL
                                RF output power                            -68               dBm
                                System                                   GSM 850



      2.3.1        GSM 850 Low TCH Test Limits
                                     Measurement                  Test Limits                  Unit
                                TX power                           29 +/-4                      dB
                                RMS Phase error                     0 +/-5                     deg
                                Rx Level                            34-50                       dB
                                Rx Quality                           0-3                       Units



      2.4     GSM 850 Mid TCH Measurements
                                               Parameter                  Value              Unit
                                TCH                                        Mid                Ch
                                TX power level                             Mid                PL
                                RF output power                           -102               dBm
                                System                                   GSM 850

      2.4.1        GSM 850 Mid TCH Test Limits
                                     Measurement                  Test Limits                  Unit
                                TX power                            19 +/-5                     dB
                                RMS Phase error                      0 +/-5                    deg
                                Peak Phase error                    0 +/-20                    deg
                                Freq error                        +/-0.1 ppm                    Hz
                                Rx Level                              2-14                      dB
                                Rx Quality                             0-3                     Units




1211-1568 4                                                                                                 7(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                             Go/No Go Test Script Specification, Electrical

      2.5     GSM 850 High TCH Measurements
                                               Parameter                Value              Unit
                                TCH                                     High                Ch
                                TX power level                           Low                PL
                                RF output power                          -68               dBm
                                System                                 GSM 850

      2.5.1        GSM 850 High TCH Test Limits
                                     Measurement                Test Limits                   Unit
                                TX power                          5 +/-7                      dB
                                RMS Phase error                   0 +/-5                      deg




      2.6     GSM 1900 Low TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                     Low                 Ch
                                TX power level                          Low                 PL
                                RF output power                         -68                dBm
                                System                                GSM 1900

      2.6.1        GSM 1900 Low TCH Test Limits
                                     Measurement                Test Limits                  Unit
                                TX power                          0 +/-7                      dB
                                RMS Phase Error                   0 +/-5                     deg
                                Rx Level                          34-50                       dB
                                RX Quality                         0-3                       Units




1211-1568 4                                                                                               8(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                             Go/No Go Test Script Specification, Electrical

      2.7     GSM 1900 Mid TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                      Mid                Ch
                                TX power level                           Mid                PL
                                RF output power                         -102               dBm
                                System                                GSM 1900

      2.7.1        GSM 1900 Mid TCH Test Limits
                                      Measurement               Test Limits                  Unit
                                TX power                          14 +/-5                     dB
                                RMS Phase error                    0 +/-5                    deg
                                Peak Phase error                  0 +/-20                    deg
                                Freq. error                     +/-0.1 ppm                    Hz
                                Rx Level                            2-14                      dB
                                Rx Quality                           0-3                     Units




      2.8     GSM 1900 High TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                     High                Ch
                                TX power level                          High                PL
                                RF output power                         -68                dBm
                                System                                GSM 1900



      2.8.1        GSM 1900 High TCH Test Limits
                                     Measurement                Test Limits                   Unit
                                TX power                         30 +/-4                      dB
                                RMS Phase error                   0 +/-5                      deg




1211-1568 4                                                                                               9(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                             Go/No Go Test Script Specification, Electrical

      2.9     GSM 1800 Low TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                     Low                 Ch
                                TX power level                          High                PL
                                RF output power                         -68                dBm
                                System                                GSM 1800

      2.9.1        GSM 1800 Low TCH Test Limits
                                     Measurement                Test Limits                  Unit
                                TX power                         30 +/-4                      dB
                                RMS Phase Error                   0 +/-5                     deg
                                Rx Level                          34-50                       dB
                                RX Quality                         0-3                       Units




      2.10 GSM 1800 Mid TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                      Mid                Ch
                                TX power level                           Mid                PL
                                RF output power                         -102               dBm
                                System                                GSM 1800




      2.10.1 GSM 1800 Mid TCH Test Limits
                                      Measurement               Test Limits                  Unit
                                TX power                          14 +/-5                     dB
                                RMS Phase error                    0 +/-5                    deg
                                Peak Phase error                  0 +/-20                    deg
                                Freq. error                     +/-0.1 ppm                    Hz
                                Rx Level                            2-14                      dB
                                Rx Quality                           0-3                     Units




1211-1568 4                                                                                             10(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                            Go/No Go Test Script Specification, Electrical




      2.11 GSM 1800 High TCH Measurements
                                              Parameter               Value               Unit
                               TCH                                     High                Ch
                               TX power level                          Low                 PL
                               RF output power                         -68                dBm
                               System                                GSM 1800



      2.11.1 GSM 1800 High TCH Test Limits
                                    Measurement                Test Limits                   Unit
                               TX power                          0 +/-7                      dB
                               RMS Phase error                   0 +/-5                      deg




      2.12 GSM 900 Low TCH Measurements
                                              Parameter                Value              Unit
                               TCH                                      Low                Ch
                               TX power level                          High                PL
                               RF output power                          -68               dBm
                               System                                 GSM 900



      2.12.1 GSM 900 Low TCH Test Limits
                                    Measurement                Test Limits                  Unit
                               TX power                         33 +/-4                      dB
                               RMS Phase error                   0 +/-5                     deg
                               Rx Level                          34-50                       dB
                               Rx Quality                         0-3                       Units




1211-1568 4                                                                                            11(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                            Go/No Go Test Script Specification, Electrical




      2.13 GSM 900 Mid TCH Measurements
                                              Parameter                Value              Unit
                               TCH                                      Mid                Ch
                               TX power level                           Mid                PL
                               RF output power                         -102               dBm
                               System                                 GSM 900

      2.13.1 GSM 900 Mid TCH Test Limits
                                    Measurement                Test Limits                  Unit
                               TX power                          19 +/-5                     dB
                               RMS Phase error                    0 +/-5                    deg
                               Peak Phase error                  0 +/-20                    deg
                               Freq error                      +/-0.1 ppm                    Hz
                               Rx Level                            2-14                      dB
                               Rx Quality                           0-3                     Units




      2.14 GSM 900 High TCH Measurements
                                              Parameter                Value              Unit
                               TCH                                     High                Ch
                               TX power level                           Low                PL
                               RF output power                          -68               dBm
                               System                                 GSM 900

      2.14.1 GSM 900 High TCH Test Limits
                                    Measurement                Test Limits                   Unit
                               TX power                          5 +/-7                      dB
                               RMS Phase error                   0 +/-5                      deg




1211-1568 4                                                                                            12(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                  Go/No Go Test Script Specification, Electrical




      2.15 UMTS 850 Low TCH Measurements (W760 only)
                                      Parameter                     Value                        Unit
                               TCH                                   Low                        Channel
                               Power Level                         Maximum                       dBm
                               RF out                                -93                         dBm




      2.15.1 UMTS 850 Low TCH Test Limits
                                             Measurement                          Test Limits      Unit
                               Tx Maximum Output Power                             19 to 27        dBm
                               EVM                                                 17.5 max         %
                               Frequency Error                                    -0.1 to 0.1      ppm
                               Tx Adjacent Channel Level Ratio +/-5MHz                -36          dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz              -46          dBc




      2.16 UMTS 850 Mid TCH Measurements (W760 only)
                                      Parameter                       Value                      Unit
                               TCH                                     Mid                      Channel
                               Power Level                          Maximum                      dBm
                               RF out                              -93 (* -104)                  dBm




      2.16.1 UMTS 850 Mid TCH Test Limits
                                               Measurement                        Test Limits      Unit
                               Tx Maximum Output Power                             19 to 27        dBm
                               EVM                                                 17.5 max         %
                               Frequency Error                                    -0.1 to 0.1      ppm
                               Tx Adjacent Channel Level Ratio +/- 5MHz               -36          dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz              -46          dBc
                               Rx Reference Sensitivity Level* (RF out: -104)     -0.1 to 0.1       %




1211-1568 4                                                                                                  13(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                Go/No Go Test Script Specification, Electrical

      2.17 UMTS 850 High TCH Measurements(W760 only)
                                      Parameter                   Value                      Unit
                               TCH                                 High                     Channel
                               Power Level                       Maximum                     dBm
                               RF out                              -93                       dBm




      2.17.1 UMTS 850 High TCH Test Limits
                                             Measurement                      Test Limits       Unit
                               Tx Maximum Output Power                         19 to 27         dBm
                               EVM                                             17.5 max          %
                               Frequency Error                                -0.1 to 0.1      degree
                               Tx Adjacent Channel Level Ratio +/- 5MHz           -36           dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz          -46           dBc




      2.18 UMTS 1900 Low TCH Measurements (W760 only)
                                      Parameter                   Value                      Unit
                               TCH                                 Low                      Channel
                               Power Level                       Maximum                     dBm
                               RF out                              -93                       dBm




      2.18.1 UMTS 1900 Low TCH Test Limits
                                             Measurement                      Test Limits       Unit
                               Tx Maximum Output Power                         19 to 27         dBm
                               EVM                                             17.5 max          %
                               Frequency Error                                -0.1 to 0.1       ppm
                               Tx Adjacent Channel Level Ratio +/- 5MHz           -36           dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz          -46           dBc




1211-1568 4                                                                                                14(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                  Go/No Go Test Script Specification, Electrical

      2.19 UMTS 1900 Mid TCH Measurements (W760 only)
                                      Parameter                       Value                      Unit
                               TCH                                     Mid                      Channel
                               Power Level                          Maximum                      dBm
                               RF out                              -93 (* -104)                  dBm




      2.19.1 UMTS 1900 Mid TCH Test Limits
                                               Measurement                        Test Limits      Unit
                               Tx Maximum Output Power                             19 to 27        dBm
                               EVM                                                 17.5 max         %
                               Frequency Error                                    -0.1 to 0.1      ppm
                               Tx Adjacent Channel Level Ratio +/- 5MHz               -36          dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz              -46          dBc
                               Rx Reference Sensitivity Level* (RF out: -104)     -0.1 to 0.1       %




      2.20 UMTS 1900 High TCH Measurements (W760 only)
                                      Parameter                     Value                        Unit
                               TCH                                   High                       Channel
                               Power Level                         Maximum                       dBm
                               RF out                                -93                         dBm




      2.20.1 UMTS 1900 High TCH Test Limits
                                             Measurement                          Test Limits      Unit
                               Tx Maximum Output Power                             19 to 27        dBm
                               EVM                                                 17.5 max         %
                               Frequency Error                                    -0.1 to 0.1     degree
                               Tx Adjacent Channel Level Ratio +/- 5MHz               -36          dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz              -46          dBc




1211-1568 4                                                                                                  15(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                  Go/No Go Test Script Specification, Electrical

      2.21 UMTS 2100 Low TCH Measurements (W760 only)
                                      Parameter                     Value                        Unit
                               TCH                                   Low                        Channel
                               Power Level                         Maximum                       dBm
                               RF out                                -93                         dBm




      2.21.1 UMTS 2100 Low TCH Test Limits
                                             Measurement                          Test Limits      Unit
                               Tx Maximum Output Power                             19 to 27        dBm
                               EVM                                                 17.5 max         %
                               Frequency Error                                    -0.1 to 0.1      ppm
                               Tx Adjacent Channel Level Ratio +/- 5MHz               -36          dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz              -46          dBc




      2.22 UMTS 2100 Mid TCH Measurements (W760 only)
                                      Parameter                       Value                      Unit
                               TCH                                     Mid                      Channel
                               Power Level                          Maximum                      dBm
                               RF out                              -93 (* -104)                  dBm




      2.22.1 UMTS 2100 Mid TCH Test Limits
                                               Measurement                        Test Limits      Unit
                               Tx Maximum Output Power                             19 to 27        dBm
                               EVM                                                 17.5 max         %
                               Frequency Error                                    -0.1 to 0.1      ppm
                               Tx Adjacent Channel Level Ratio +/- 5MHz               -36          dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz              -46          dBc
                               Rx Reference Sensitivity Level* (RF out: -104)     -0.1 to 0.1       %




1211-1568 4                                                                                                  16(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                Go/No Go Test Script Specification, Electrical

      2.23 UMTS 2100 High TCH Measurements (W760 only)
                                      Parameter                   Value                      Unit
                               TCH                                 High                     Channel
                               Power Level                       Maximum                     dBm
                               RF out                              -93                       dBm




      2.23.1 UMTS 2100 High TCH Test Limits
                                             Measurement                      Test Limits       Unit
                               Tx Maximum Output Power                         19 to 27         dBm
                               EVM                                             17.5 max          %
                               Frequency Error                                -0.1 to 0.1      degree
                               Tx Adjacent Channel Level Ratio +/- 5MHz           -36           dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz          -46           dBc




      2.23.2 Call Disconnect Sequence

                           1. Disconnect call.

                           2. End test.




1211-1568 4                                                                                                17(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                 Go/No Go Test Script Specification, Electrical


3 Test Sequence - Conducted


      3.1     Initializing and Call Setup
                                               Parameter                    Value              Unit
                                BCCH                                         Mid                Ch
                                TCH                                          Mid                Ch
                                TX power level                              High                PL
                                RF output power                              -40               dBm
                                System                                     GSM 850



      3.1.1        Sequence

                            1. Initialize instrument

                            2. Insert a test-SIM and attach a fully charged standard battery to the mobile.
                                It's very important that a fully charged battery is used otherwise there is a
                                high risk for incorrect test results. A dummy battery can also be used.

                            3. Remove the Battery cover and Antenna plug from the back of the handset and
                               connect the mobile to the RF fixture according to the picture.




                            4. Turn on the mobile and wait for registration.
                            5. Set up a call to the instrument or let the instrument call the MS.



1211-1568 4                                                                                                 18(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                               Go/No Go Test Script Specification, Electrical

      3.2     Audio Loopback
                   1.   Set power level to high.
                   2.   Activate audio loopback in the instrument.
                   3.   Operator must acknowledge passed or failed before the test is continued.


      3.3     GSM 850 Low TCH Measurements
                                               Parameter                    Value            Unit
                                TCH                                          Low              Ch
                                TX power level                              High              PL
                                RF output power                              -68             dBm
                                System                                     GSM 850



      3.3.1        GSM 850 Low TCH Test Limits
                                     Measurement                     Test Limits               Unit
                                TX power                              29 +/-2                   dB
                                RMS Phase error                        0 +/-5                  deg
                                Rx Level                               36-48                    dB
                                Rx Quality                              0-3                    Units




      3.4     GSM 850 Mid TCH Measurements
                                               Parameter                    Value            Unit
                                TCH                                          Mid              Ch
                                TX power level                               Mid              PL
                                RF output power                             -102             dBm
                                System                                     GSM 850

      3.4.1        GSM 850 Mid TCH Test Limits
                                     Measurement                     Test Limits               Unit
                                TX power                               19 +/-3                  dB
                                RMS Phase error                         0 +/-5                 deg
                                Peak Phase error                       0 +/-20                 deg
                                Freq error                           +/-0.1 ppm                 Hz
                                Rx Level                                 4-12                   dB
                                Rx Quality                                0-3                  Units




1211-1568 4                                                                                               19(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                             Go/No Go Test Script Specification, Electrical




      3.5     GSM 850 High TCH Measurements
                                               Parameter                Value              Unit
                                TCH                                     High                Ch
                                TX power level                           Low                PL
                                RF output power                          -68               dBm
                                System                                 GSM 850

      3.5.1        GSM 850 High TCH Test Limits
                                     Measurement                Test Limits                   Unit
                                TX power                          5 +/-5                      dB
                                RMS Phase error                   0 +/-5                      deg




      3.6     GSM 1900 Low TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                     Low                 Ch
                                TX power level                          Low                 PL
                                RF output power                         -68                dBm
                                System                                GSM 1900

      3.6.1        GSM 1900 Low TCH Test Limits
                                     Measurement                Test Limits                  Unit
                                TX power                          0 +/-5                      dB
                                RMS Phase error                   0 +/-5                     deg
                                Rx Level                          36-48                       dB
                                RX Quality                         0-3                       Units




1211-1568 4                                                                                             20(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                             Go/No Go Test Script Specification, Electrical




      3.7     GSM 1900 Mid TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                      Mid                Ch
                                TX power level                           Mid                PL
                                RF output power                         -102               dBm
                                System                                GSM 1900

      3.7.1        GSM 1900 Mid TCH Test Limits
                                      Measurement               Test Limits                  Unit
                                TX power                          14 +/-3                     dB
                                RMS Phase error                    0 +/-5                    deg
                                Peak Phase error                  0 +/-20                    deg
                                Freq. error                     +/-0.1 ppm                    Hz
                                Rx Level                            4-12                      dB
                                Rx Quality                           0-3                     Units




      3.8     GSM 1900 High TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                     High                Ch
                                TX power level                          High                PL
                                RF output power                         -68                dBm
                                System                                GSM 1900



      3.8.1        GSM 1900 High TCH Test Limits
                                     Measurement                Test Limits                   Unit
                                TX power                         30 +/-2                      dB
                                RMS Phase error                   0 +/-5                      deg




1211-1568 4                                                                                             21(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                             Go/No Go Test Script Specification, Electrical

      3.9     GSM 1800 Low TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                     Low                 Ch
                                TX power level                          High                PL
                                RF output power                         -68                dBm
                                System                                GSM 1800

      3.9.1        GSM 1800 Low TCH Test Limits
                                     Measurement                Test Limits                  Unit
                                TX power                         30 +/-2                      dB
                                RMS Phase Error                   0 +/-5                     deg
                                Rx Level                          36-48                       dB
                                RX Quality                         0-3                       Units




      3.10 GSM 1800 Mid TCH Measurements
                                               Parameter               Value               Unit
                                TCH                                      Mid                Ch
                                TX power level                           Mid                PL
                                RF output power                         -102               dBm
                                System                                GSM 1800

      3.10.1 GSM 1800 Mid TCH Test Limits
                                      Measurement               Test Limits                  Unit
                                TX power                          14 +/-3                     dB
                                RMS Phase error                    0 +/-5                    deg
                                Peak Phase error                  0 +/-20                    deg
                                Freq. error                     +/-0.1 ppm                    Hz
                                Rx Level                            4-12                      dB
                                Rx Quality                           0-3                     Units




1211-1568 4                                                                                             22(34)
Company Internal    Sony Ericsson Mobile Communications AB
                                                            Go/No Go Test Script Specification, Electrical




      3.11 GSM 1800 High TCH Measurements
                                              Parameter               Value               Unit
                               TCH                                     High                Ch
                               TX power level                          Low                 PL
                               RF output power                         -68                dBm
                               System                                GSM 1800



      3.11.1 GSM 1800 High TCH Test Limits
                                    Measurement                Test Limits                   Unit
                               TX power                          0 +/-5                      dB
                               RMS Phase error                   0 +/-5                      deg




      3.12 GSM 900 Low TCH Measurements
                                              Parameter                Value              Unit
                               TCH                                      Low                Ch
                               TX power level                          High                PL
                               RF output power                          -68               dBm
                               System                                 GSM 900



      3.12.1 GSM 900 Low TCH Test Limits
                                    Measurement                Test Limits                  Unit
                               TX power                         33 +/-2                      dB
                               RMS Phase error                   0 +/-5                     deg
                               Rx Level                          36-48                       dB
                               Rx Quality                         0-3                       Units




1211-1568 4                                                                                            23(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                            Go/No Go Test Script Specification, Electrical

      3.13 GSM 900 Mid TCH Measurements
                                              Parameter                Value              Unit
                               TCH                                      Mid                Ch
                               TX power level                           Mid                PL
                               RF output power                         -102               dBm
                               System                                 GSM 900

      3.13.1 GSM 900 Mid TCH Test Limits
                                    Measurement                Test Limits                  Unit
                               TX power                          19 +/-3                     dB
                               RMS Phase error                    0 +/-5                    deg
                               Peak Phase error                  0 +/-20                    deg
                               Freq error                      +/-0.1 ppm                    Hz
                               Rx Level                            4-12                      dB
                               Rx Quality                           0-3                     Units




      3.14 GSM 900 High TCH Measurements
                                              Parameter                Value              Unit
                               TCH                                     High                Ch
                               TX power level                           Low                PL
                               RF output power                          -68               dBm
                               System                                 GSM 900

      3.14.1 GSM 900 High TCH Test Limits
                                    Measurement                Test Limits                   Unit
                               TX power                          5 +/-5                      dB
                               RMS Phase error                   0 +/-5                      deg




1211-1568 4                                                                                            24(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                  Go/No Go Test Script Specification, Electrical

      3.15 UMTS 850 Low TCH Measurements (W760 only)
                                      Parameter                     Value                        Unit
                               TCH                                   Low                        Channel
                               Power Level                         Maximum                       dBm
                               RF out                                -93                         dBm




      3.15.1 UMTS 850 Low TCH Test Limits
                                             Measurement                          Test Limits      Unit
                               Tx Maximum Output Power                             21 to 25        dBm
                               EVM                                                 17.5 max         %
                               Frequency Error                                    -0.1 to 0.1      ppm
                               Tx Adjacent Channel Level Ratio +/- 5MHz               -36          dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz              -46          dBc




      3.16 UMTS 850 Mid TCH Measurements (W760 only)
                                      Parameter                       Value                      Unit
                               TCH                                     Mid                      Channel
                               Power Level                          Maximum                      dBm
                               RF out                              -93 (* -104)                  dBm




      3.16.1 UMTS 850 Mid TCH Test Limits
                                               Measurement                        Test Limits      Unit
                               Tx Maximum Output Power                             21 to 25        dBm
                               EVM                                                 17.5 max         %
                               Frequency Error                                    -0.1 to 0.1      ppm
                               Tx Adjacent Channel Level Ratio +/- 5MHz               -36          dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz              -46          dBc
                               Rx Reference Sensitivity Level* (RF out: -104)     -0.1 to 0.1       %




1211-1568 4                                                                                                  25(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                Go/No Go Test Script Specification, Electrical

      3.17 UMTS 850 High TCH Measurements (W760 only)
                                      Parameter                   Value                      Unit
                               TCH                                 High                     Channel
                               Power Level                       Maximum                     dBm
                               RF out                              -93                       dBm




      3.17.1 UMTS 850 High TCH Test Limits
                                             Measurement                      Test Limits       Unit
                               Tx Maximum Output Power                         21 to 25         dBm
                               EVM                                             17.5 max          %
                               Frequency Error                                -0.1 to 0.1      degree
                               Tx Adjacent Channel Level Ratio +/- 5MHz           -36           dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz          -46           dBc




      3.18 UMTS 1900 Low TCH Measurements (W760 only)
                                      Parameter                   Value                      Unit
                               TCH                                 Low                      Channel
                               Power Level                       Maximum                     dBm
                               RF out                              -93                       dBm




      3.18.1 UMTS 1900 Low TCH Test Limits
                                             Measurement                      Test Limits       Unit
                               Tx Maximum Output Power                         21 to 25         dBm
                               EVM                                             17.5 max          %
                               Frequency Error                                -0.1 to 0.1       ppm
                               Tx Adjacent Channel Level Ratio +/- 5MHz           -36           dBc
                               Tx Adjacent Channel Level Ratio +/- 10MHz          -46           dBc




1211-1568 4                                                                                                26(34)
Company Internal   Sony Ericsson Mobile Communications AB
                                                                  Go/No Go Test Script Specification, Electrical

      3.19 UMTS 1900 Mid TCH Measurements (W760 only)
                                      Parameter                       Value                      Unit
                               TCH                                     Mid                      Channel
                               Power Level                          Maximum                      dBm
                               RF out                              -93 (* -104)                  dBm




      3.19.1 UMTS 1900 Mid TCH Test Limits
                                               Measurement                        Test Limits      Unit
                               Tx Maximum Output Power                             21 to 25        dBm
                               EVM                                                 17.5 max         %
                               Frequency Error                    