                                        TM 11-6625-2980-14

          TECHNICAL MANUAL

    OPERATOR'S, ORGANIZATIONAL,
    DIRECT SUPPORT AND GENERAL
    SUPPORT MAINTENANCE MANUAL
                FOR
    PULSE GENERATOR AN/USM-359A

         (NSN 6625-01-077-4620)

 (TEKTRONIX MODEL PG 508 WITH TM 503)

HEADQUARTERS, DEPARTMENT OF THE ARMY

                                          27 MARCH 1981
                                                                                                  TM 11-6625-2980-14

                                                 SAFETY SUMMARY

     This manual contains safety information which the user must follow to ensure safe operation of this instrument.
WARNING information is intended to protect the operator; CAUTION information is intended to protect the instrument.
The following general safety precautions must be observed during all phases of operation, service, and repair of this
instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety
standards of design, manufacture, and intended use of the instrument.

    Warning statements precede potentially dangerous procedures throughout this manual. The instructions contained in
the warnings must be followed. The following warning statements are found in this manual.

                                                      WARNING

       Use a proper power source. This instrument is designed to operate from a power source with its neutral
       at or near ground potential with a separate safety-earth conductor. It is not intended for operation from
       two phases of a multi-phase system, or across the legs of a single-phase, three-wire system.


                                                      WARNING

       Avoid live circuits. Dangerous voltages exist at several points throughout this instrument. When the
       instrument is operated with the cover removed, do not touch exposed connections or components. Some
       transistors have voltages present on their cases. Disconnect power before cleaning the instrument or
       replacing parts.

                                                      WARNING

       Avoid contact with chemicals. Handle silicone grease with care. Avoid getting silicon-in grease in
       eyes. Wash hands thoroughly after use.

                                                      WARNING

       Adequate ventilation should be provided while using TRICHLOROTRIFLUOROETHANE. Prolonged
       breathing of vapor should be avoided. The solvent should not be used near heat or open flames; the
       products of decomposition are toxic and irritating. Since TRICHLOROTRIFLUOROETHANE dissolves
       natural oils, prolonged contact wit h skin should be avoided. When necessary,-use gloves which the
       solvent cannot penetrate. If the solvent is taken internally, consult a-physician immediately.

                                                      WARNING

       Compressed air is dangerous and can cause serious bodily harm if protective means or methods are not
       observed to prevent a chip or particle (of whatever size) from being blown into the eyes or unbroken skin
       of the operator or other personnel. Compressed air shall not be used for cleaning purposes except where
       reduced to less than 30 p.s.i.f. and then only with effective chip guarding and personnel protective
       equipment. Do not use compressed air to dry parts when Trichlorotrifloroethane has been used.

                                                      CAUTION

       Avoid power surge damage. Do not remove or install plug-in unit while power is on as damage may
       occur to circuitry.
                                                                                                 TM 11-6625-2980-14

This manual contains copyright material reproduced b)y permission of Tektronix. Inc.

TECHNICAL MANUAL                                                                             HEADQUARTERS
                                                                                        DEPARTMENT OF THE ARMY
No. 11-6625-2980-14                                                                    WASHINGTON, DC, 27 March 1981

                            OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT, AND
                                GENERAL SUPPORT MAINTENANCE MANUAL
                                                  FOR
                                    GENERATOR, PULSE AN/USM-359A
                                 (TEKTRONIX MODEL PG 508 WITH TM 503)
                                          (NSN 6625-01-077-4620)

                         REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS
                       You can help improve this manual. If you find any mistakes or if you know of a way to
                  improve the procedures, please let us know. Mail your letter, DA Form 2028 (Recommended
                  Changes to Publications and Blank Forms), or DA Form 2028-2 located in back of this
                  manual direct to: Commander, US Army Communications and Electronics Materiel
                  Readiness Command, ATTN: DRSEL-ME-MQ, Fort Monmouth, New Jersey 07703.

This manual is an authentication of the manufacturer's commercial literature which, through usage, has been found to
cover the data required to operate and maintain this equipment. Since the manual was not prepared in accordance with
military specifications, the format has not been structured to consider levels of maintenance.
                                                                                                TM 11-6625-2980-14
                                                    TABLE OF CONTENTS

                                                   Page                                                    Page
Section 0   INTRODUCTION                           0-1      APPENDIX A TM 503 MAINFRAME
                                                            Section I.       INSTALLATION PROCEDURE       A-1
SECTION 1   OPERATING INSTRUCTIONS
            Instrument Description                 1-1      Section II.     TM 503 OPERATING
                                                                            INSTRUCTIONS                   A-3
            Installation and Removal               1-1                      Introduction                   A-3
            BASIC OPERATION                        1-2                      Powering Up                    A-3
            Period and Duration Selection          1-2                      Building a System              A-5
            Duty Factors                           1-2                      Specifications                 A-6
            Delayed and Paired Pulse Selection     1-2
            Transition Time Selection              1-3      Section III.
                                                                       TM 503 SYSTEM MAINTENANCE           A-7
            Transition Time Selection              1-3                 General                             A-7
            External Triggering and Gating         1-3                 Troubleshooting Aids                A-8
            Trigger Output                         1-4                 Troubleshooting Techniques          A-8
            Manual Trigger                         1-4                 Parts Replacement                   A-10
            Control Error Light                    1-4                 Diagrams and Circuit Board
            Control Error Light                    1-4                 Illustrations                       A-14
            OPERATING CONSIDERATIONS               1-4                 Power Module Interface Pin
            Output Termination's and                                   Assignments                         A-15
            Connections                            1-4                 Detailed Block Diagram              A-16
            Connections                            1-4                 Parts Location Grid                 A-17
            Rise Time Measurements in Linear                           Parts Location Grid                 A-17
            Systems                                1-5                 Replaceable Mechanical Parts        A-19
            Counted Burst Using the DD 501                  APPENDIX B REFERENCES
            External Voltage Control               1-5
            Digital Delay Unit                     1-5
            Definitions of Pulse Characteristics   1-8      APPENDIX C COMPONENTS OF END ITEM AND
            SPECIFICATIONS                         1-9                 BASIC ISSUE ITEMS LIST
            Environmental Requirements             1-11     Section I. INTRODUCTION                        C-1
            Using the Rear Interface                                   Scope                               C-1
            Connectors                             1-12                General                             C-1
                                                                       Explanation of Columns              C-1
SECTION 2   THEORY OF OPERATION
            Introduction                           2-1      Section II.     COMPONENTS OF END ITEM         C-2
            Input Circuitry                        2-1      Section III.    BASIC ISSUE ITEMS              C-3
            ~ TRIG'D/GATED Light Circuitry         2-1
            Triggered Mode                         2-1      APPENDIX D ADDITIONAL AUTHORIZATION
            Period Generator                       2-2                 LIST (Not Applicable)
            Delay Generator                        2-2
            Duration Generator                     2-2      APPENDIX E MAINTENANCE ALLOCATION
            Duration and Delay Control Error                Section I. INTRODUCTION                        E-1
            Light Circuitry                        2-3                 General                             E-1
            Variable Transition Time Circuitry     2-3                 Maintenance Function                E-1
            Transition Time Control Error                              Column Entries                      E-2
            Light Circuitry                        2-3                 Tool and Test Equipment
            Level Control Multiplier               2-5                 Requirement                         E-2
            Output Amplifier                       2-6
            Power Supply                           2-6                      Remarks                        E-2
                                                            Section II.     MAINTENANCE ALLOCATION
SECTION 3   SERVICE INFORMATION                                             CHART OR PULSE
            Symbols and Reference Designators      3-1                      GENERATOR AN/USM-359A          E-3
            General Maintenance and                          Section III.   TOOL AND TEST EQUIPMENT
            Adjustments                            3-2                      REQUIREMENTS FOR PULSE
            Maintenance                            3-2                      GENERATOR AN/USM-359A          E-5
            Circuit Board Removal                  3-2
            Circuit Board Removal                  3-2      APPENDIX F EXPENDABLE SUPPLIES AND
            Test Equipment                         3-2                  MATERIALS LIST
            General                                3-2      Section I.  INTRODUCTION                       F-1
SECTION 4   CONTROLS AND CONNECTORS                                     Scope                              F-1
            AND SCHEMATIC DIAGRAMS                 4-1                  Explanation of Columns             F-1
SECTION 5   REPLACEABLE MECHANICAL                          Section II. EXPENDABLE SUPPLIES AND
            PARTS LIST                             5-1                  MATERIALS                          F-2

                                                           iii
                                                                                                            TM 11-6625-2980-14
                                                    LIST OF ILLUSTRATIONS

Fig.                                                     Page                                                 Page
No.                                                       No.                                                  No.
1-0      Pulse Generator AN/USM-359A.                     vi         FO-1    Controls and connectors.                     4-1
1-1    PG 508 installation and removal.                  1-1         FO-2    Block diagram.                               4-3
1-2    Locations of period, delay and duration                       FO-3    Input circuit schematic diagram.             4-5
       custom timing capacitors and TRIG/GATE                        FO-4    Period generator schematic diagram.          4-7
       input impedance switch.                           1-2         FO-5    Delay generator schematic diagram.           4-9
1-3    Location for transition custom timing                         FO-6    Duration generator and control error circuit
       capacitor.                                        1-3                 schematic diagram.                           4-11
1-4    Equivalent circuit of external input for output               FO-7    Transition time generator schematic diagram. 4-13
       voltage control.                                  1-5         FO-8    Level control multiplier schematic diagram.4-15
1-5    Location of trigger jumpers in DD 501 for                     FO-9    Output amplifier schematic diagram.          4-17
       selecting trigger or delay interval output        1-6         FO-10   Tracking voltage supply schematic diagram.   4-19
1-6    PG 508-DD 502 interconnections for counted                    FO-11   PG 508 power supply schematic diagram.       4-21
       burst operation.1-6                                           FO-12   TM 503 power supply schematic diagram.       4-23
1-7    Typical propagation delays using PG 508 with                  5-1     Al board component locations.                5-2
       DD 501 in counted burst mode at 50 MHz                        FO-13   A2 board component locations.                5-3
       repetition rate.                                  1-7         FO-14   A3 board component locations.                5-5
1-8    Pulse characteristics.                            1-8         FO-15   A4 board component locations.                5-7
1-9    Locations for user installed rear interface                   FO-16   PG 508 exploded view.                        5-9
       connections.                                      1-12
2-1    Simplified schematic for
       control error indicator
       logic with control settings
       causing illumination.                             2-4

                                                                iv
                                           TM 11-6625-2980-14




Figure 1-0 . Pulse generator AN/USM-359A

                   vi
                                                                                                    TM 11-6625-2980-14

                                                     SECTION O

                                                   INTRODUCTION


Scope                                                               c. Discrepancy in Shipment Report (DISREP) (SF
                                                                 361). Fill out and forward Discrepancy in Shipment
   This manual describes Pulse Generator AN/USM-                 Report (DISREP) (SF 361) as prescribed in AR 55-38/
359A and provides instructions for operation and                 NA.VSUPI NST 4610.33B/AFR 75-18/MCO P4610.19C
maintenance. Throughout this manual, the SG-                     and DLAR 4500.15.
1178/USM-359A is referred to as Tektronix Model PG
508 and PP-7578/USM 359A is referred to as TM 503.               Reporting       Equipment                Improvement
                                                                 Recommendations (EIR)
Indexes of Publications
                                                                      If your AN/USM-359A needs improvement, let us
     a. DA Pam 310-4. Refer to the latest issue of DA            know. Send us an EIR. You, the user, are the only one
Pam 310-4 to determine whether there are New                     who can tell us what you don't like about your
editions, changes, or additional publications pertaining         equipment. Let us know why you don't like the design.
to the equipment.                                                Tell us why a procedure is hard to perform. Put it on an
                                                                 SF 368 (Quality Deficiency Report). Mail it to
    b. DA Pam 310-7. Refer to DA Pam 310-7 to                    Commander, US Army Communications and Electronics
determine whether there are modification work orders             Materiel Readiness Command, ATTN: DRSEL-ME-MO,
(MWO's) pertaining to the equipment.                             Fort Monmouth, New Jersey 07703. We'll send you a
                                                                 reply.
Maintenance Forms, Records, and Reports
                                                                 Administrative Storage
    Reports of Maintenance and Unsatisfactory
Equipment. Department of the Army forms and                          To prepare the equipment for administrative
procedures used for equipment maintenance will be                storage, ascertain its operability and reliability. In
those prescribed by TM 38-750, The Army Maintenance              addition, use the proper packing materials.
Management system (Army).
                                                                 Destruction of Army Electronics Materiel
    b. Report of Item and Packaging Discrepancies. Fill
out and forward SF 364 [Report of Discrepancy (ROD)]                Destruction of Army electronics materiel to prevent
as      prescribed      in    AR       735-11-2/DLAR             enemy use shall be in accordance with TM 750-244-2.
4140.55/NAVMATINS4355.73/AFR             400-54/MCO
4430.3E.

                                                           0-1
                                                                                                      TM 11-6625-2980-14
                                                                                                        Section 1-PG 508
                                                       OPERATING
                                                     INSTRUCTIONS


Instrument Description                                                  The front panel is color coded for easy reference to
                                                                   controls and their associated functions. Green indicates
     The PG 508 is a 50 MHz general purpose full                   triggering functions and blue indicates mode functions.
function pulse generator usable in all TM 500-series
power modules except the TM 501. It is compatible with             Installation and Removal
MOS and other general purpose circuitry. Important
features of the instrument include independent period                  The PG 508 is calibrated and ready for use when
and duration controls with a control error light,                  received. It operates in any two compartments of the TM
independent pulse top and bottom level controls,                   500-series power modules. See Appendix A for line
variable leading and trailing transition time adjustments,         voltage requirements and power module operation. Fig.
and fully adjustable pulse delay capabilities. Front panel         1-1 shows the installation and removal procedure. Make
controls and connectors provide a trigger or                       certain the power module is off when inserting or
synchronous gate input with level and slope controls,              removing the PG 508. Check that the PG 508 is fully
square wave output and complementary pulse output for              inserted in the power module. Pull the power switch on
high duty factors. Delayed and paired pulse and manual             the power module. The POWER light on the PG 508
trigger or gate capabilities are also provided. All inputs         should now be on. Refer to the Controls and Connectors
and outputs are internally terminated in 50 n except the           foldout page in Section 4 of this manual for a complete
TRIG/GATE input which is internally selectable for                 description of the front panel controls and connectors.
either 50 n or 1 Mn, 20 pF input impedance. Special
positions on PERIOD, DURATION, DELAY, and
TRANSITION controls permit customized control
ranges.




                                        Fig. 1-1. PG 508 installation and removal.

                                                             1-1
                                                                                                      TM 11-6625-298014


BASIC OPERATION                                                   10-2 or a 500pF capacitor. If a polarized capacitor is
                                                                  used, observe the correct polarity. Use at least a 6 V
Period and Duration Selection                                     rated capacitor. Connect this capacitor as shown in Fig.
                                                                  1-2.
    The period generator operates, in all modes except
EXT TRIG or MAN, at a rate set by the PERIOD range                Duty Factors
switch and variable control. The duration of the output
pulse is set by the DURATION range switch and                     Duty factors greater than those specified are obtainable
variable control. When the DURATION control is set for            on several ranges. When the duty factor is increased to
a time greater than the PERIOD, the CONTROL                       the point that internal circuitry prevents completion of
ERROR lamp will light. When the DURATION control is               the pulse waveform, the CONTROL ERROR light will
set to the SQ WAVE position, the duration time is                 flash. To further increase the duty factor, switch to the
determined internally at approximately 50% of the                 complement mode. Set the DURATION control for a
period time.                                                      pulse width equal to the desired pulse off time and push
                                                                  the front panel COMPLEMENT (-) pushbutton.
    The custom range positions on the PERIOD and
DURATION controls permit user-selected period and                 Delayed and Paired Pulse Selection
duration times. To determine the approximate capacitor
value for the desired period, multiply the period time in         In the pulse delay mode, the output pulse is delayed
seconds by 5 X 10-3. The result is the value of the               from the +TRIG OUT signal by the DELAY time
capacitor in Farads. For example, a 50 ms period times            selected plus a specified fixed delay. In the PAIRED
5 X 10-3 equals 250 X 10- or 250 HF. This capacitor               mode of operation, the delay controls the time between
must be non-polarized and have at least a 6 V rating.             the leading edges of the paired pulses. To use this
Solder this capacitor in the position shown in Fig. 1-2.          feature push the DELAY button and trigger the external
                                                                  device from the +TRIG OUT jack. Set the DELAY
    To determine the capacitor value for the duration             control for the desired delay time from trigger to pulse
time desired, multiply the duration time by 1 X 10-2. For         leading edge. Use the variable control labeled CAL for
example a 50 ms duration time requires 50 ms times 1              time adjustments between steps or to increase the delay
X                                                                 times beyond the steps.




           Fig. 1-2. Locations of period, delay and duration custom timing capacitors and TRIG/GATE IN input
                      impedance switch. Remove the Input board to gain access to the delay pads.

                                                            1-2
                                                                                                         TM 11-6625-2980-14

     Paired pulses are obtained by pushing both the
DELAY and UNDLY buttons. An initial pulse now occurs
at external trigger time with the second or paired pulse
delayed by the selected delay time. The CONTROL
ERROR light illuminates if the delay is too short or long
for a valid pulse train. A custom delay position is
provided on the DELAY switch. To determine the value
of the capacitor required, multiply the desired delay time
in seconds by 1 X 10-2. For example, a 50 ms delay
time requires a 500 Pf capacitor (50 ms times 1 X 10-2).
Use either a polarized or non-polarized capacitor with a
rating of at least 6 V. If a polarized capacitor is used,
observe the polarity markings. Remove the input board
and connect the capacitor as shown in Fig. 1-2.

Transition Time Selection
     The leading and trailing times of the pulses may be
varied by using the TRANSITION TIME control and the
LEADING and TRAILING variable controls. Select the
desired transition time range with the TRANSITION                       Fig. 1-3 . Location for transition custom timing
TIME control and vary the leading and trailing times                                      capacitor .
independently with the LEADING and TRAILING
controls.                                                                The pulse high and low levels can be preset. Push
     A custom range position is also provided on the                 the PRESET button and adjust the HIGH LEVEL and the
TRANSITION TIME control. To select the correct                       LOW LEVEL potentiometers with a screwdriver for the
capacitor (in Farads) for this range, multiply the desired           desired output levels.
transition time (in seconds) measured from 10% to 90%
points, by 4.4 X 10-'. For example, a desired transition             External Triggering and Gating
time of 50 ms requires a capacitor of 220 HF. Connect
                                                                          To change the TRIG/GATE IN input impedance
the capacitor as shown in Fig. 1-3. Use a capacitor with
                                                                     remove the plug-in from the mainframe. Remove the
at least a 10 V rating and observe polarity requirements.
                                                                     left side cover. Set the slide switch, located on the Input
     When the transition times become large compared
                                                                     board and labeled Input Impedance, to either the 50 n or
with the duration or period times and the pulse does not
                                                                     the 1 MO position. In the 1 MO position the shunt
reach full amplitude, the CONTROL ERROR light will
                                                                     capacitance is approximately 20 pF. A standard
flash indicating improper control settings.
                                                                     oscilloscope probe can be used to acquire the triggering
                                                                     signal from the external circuitry. If a compensated
Output Levels                                                        probe is used, calibrate the probe on the input of a 1 M)
     The output amplitude and offset are selected by                 20 pF oscilloscope first. A 10X probe allows triggering
independent pulse LOW LEVEL and HIGH LEVEL                           directly from high impedance sources such as MOS
controls. Use the front panel voltage calibration marks              digital circuitry with an effective TRIG/GATE LEVEL
for an open circuit load and divide the values by two                range of 