Service Manuals, User Guides, Schematic Diagrams or docs for : Tektronix TDS7000 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 Applications 07_HT3-1.3 Readme

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Preview not available!
Sorry, no preview image available for this document.
Possible reasons are : this is not a PDF document, it is password protected or the file is partially corrupted.
We are working to fix the issue.
You can still download the full file from the link below and it will be viewable.



>> Download Readme documenatation <<

Text preview - extract from the document
HDMI Compliance Test Software (1.3)

Product:  TDSHT3v1-3
Version:  3.3.2
Date   :  16-July-07

===============================================================

What is in this file:

1. System Requirements
2. Features
3. Known Problems/Issues
4. Installation 
5. Starting the Application
6. Contents of Distribution
7. Contact Tektronix

===============================================================
1. System Requirements
 
- The TDSHT3v1.3 application is targeted towards DPO/DSA 70000,
  TDS7000B/CSA7000B,TDS6000/TDS6000B,TDS6000C,TDS7000/ CSA7000 series   oscilloscopes.
 
- Report Generator Version: 3.01.000 or above
  (This application will not  install Report Generator . Report Generator is a common 
   feature shared by several applications. You can install Report Generator from the
   Optional application CD. You can check the version from Report Generator Help>About.)
  Report Generator 3.01.000 or above can be downloaded from Tektronix website at
  http://www.tek.com, select Software and drivers and enter keyword "Report Generator".

 
- Minimum amount of disk space required for the application: 240MB
 
- Tek Scope latest Firmware updates can be downloaded from the Tektronix website 
  at http://www.tek.com/Measurement/scopes/index.html. Click on 
  "Software & Drivers" under the "Resources" set of links on the left. 
 
- Sun Microsystems' Java Runtime Environment (JRE) version 1.4.2_02 is required 
  for this release; it will automatically be installed with TDSHT3v1-3 if it is 
  not already present on your oscilloscope. If the JRE is deleted, restore it 
  through the TDSHT3v1-3 installation.

- TekScope firmware updates can be downloaded from the Tektronix website
  at http://www.tek.com/Measurement/scopes/index.html.  
  Under the "Resources" group, click "Software and Drivers".

- The TDSHT3v1-3 application requires 256/512MB or more of (windows) system memory.

- Disk space requirements:
  ~240MB of free disk space to install and operate the application.

- Keyboard: 
  Save/Recall features require the use of a keyboard to enter file or folder 
  names.

- Mouse: 
  Though a mouse is not required, we recommend its use with this
  application.

- The best MS Windows(TM) task bar settings for running this application with
  a mouse (without a keyboard) is:
	Always on top = selected
    	Auto Hide     = selected

===============================================================

2. Features

- Conformance to HDMI standards and test specifications (CTS-1.3b) ensures reliable 
  results

- Complete validation to standards with wide range of tests for Source, Sink,
  and Cable devices

- Accurate Source tests by using precise measurement techniques

- Dependable Sink tests with closed-loop measurements that eliminate 
  non-linearities in test setup

- Shrink test times by automating complex Sink and Cable tests with remote 
  control of signal sources

- Get quick results with automatic Mask-Fit, measurements, and Pass/Fail 
  notification 

- Get in-depth analysis with statistical analysis and mask margins

- Ensure faster testing with one-button selection of multiple tests

- Save time with one-button csv-format summary and reports 

- Complete compliance solution with an elaborate test fixture, signal sources, 
  and TDR

- HDMI Compliance Test Software (1.3) also supports the "save and recall setup"feature

- Online help, the PDF of the online help, and Quick Start User Manuals can 
  be started from:
      Start > Programs > TekApplications > TDSHT3v1-3 > Help   
      Start > Programs > TekApplications > TDSHT3v1-3 > Help (PDF Version)
      Start > Programs > TekApplications > TDSHT3v1-3 > Quick Start User Manual
      (English)
      Start > Programs > TekApplications > TDSHT3v1-3 > Quick Start User Manual
      (Japanese)

================================================================================

3. Known Limitations

- Before performing any test:
   i. Ensure that the probes and test fixtures are connected properly. 
   ii. It is recommended to do the probe calibration.
  If you do not follow the above steps, then the results may be invalid.

- Results: In Eye Diagram and Jitter Plot, if there is no data within a 
  histogram box, you will see the histogram readout on the plots as "--" and the 
  histogram will not be displayed. Increase the record length and try again.

- Report remarks/comments: If the remarks/comments are too long, 
  they might get clipped in the generated report.

- Generated reports can become fragmented during .rtf exporting when
  graphics, tables, and result fields close to the right margin are used
  in the layout. The default templates provided with this product are
  left justified.

- If a printer is not configured on your oscilloscope, you may see a message
  box, "You must first configure a printer." when you run the application. Click 
  OK and then configure a printer.

-In some of the Windows Operating System,the scope screen shot in the test report(.rpt file)
  may be shrunk.

- While running the Min/Max Differential sensitivity test with SMA7313 probe, manually
  change the Attn dynamic range of the probe to 2.5X


================================================================================

4. Installation

4.1 TDSHT3v1-3 (HDMI Compliance Test Software(1.3))

  By default, the TDSHT3v1-3 application resides on the hard drive of your
  oscilloscope. If the application is not installed on the hard disk, perform 
  the following steps to install the application from the Optional 
  Applications Software on a Windows-Based Oscilloscope Compact disc (CD-ROM):

  i. If the keyboard is not installed, connect it to the oscilloscope rear panel
     (the optional-accessory keyboard plugs into the USB connector).

  ii. Power on the oscilloscope to start Windows.

  iii. Install the optional applications software CD in the CD-ROM reader 
       of the oscilloscope.

  iv. The autorun utility will start the installation program. If the autorun 
      utility does not start up automatically, browse to the CD-ROM and 
      double-click launch.exe.

  v. Click 'HDMI Compliance Test (1.3)'.

  vi. Click 'INSTALL NOW'.

  vii. Follow the instructions given by the TDSHT3v1-3 InstallShield Wizard. 
       If Sun Microsystems' Java Runtime Environment (JRE) version 1.4.2_02 software
       is not previously installed, then the InstallShield Wizard will prompt for 
       installing it. Follow the instructions to install the JRE. After 
       successful installation of JRE, choose to restart the oscilloscope 	
       later and continue installing TDSHT3v1-3.

  viii. When the installation is complete, the InstallShield Wizard asks if 
        you want to restart the oscilloscope. Click Yes.

  ix. Enter the authorized Option Installation Key to enable the application. 
      The key is specific to the serialized oscilloscope and options for which 
      it was purchased. To enter the key number, follow these steps:

	a. If the oscilloscope is powered on in the toolbar mode (default), 
	   select the Menu button (upper right corner of the display) to 
	   put the oscilloscope into menu-bar mode. In menu-bar mode, you 
	   should see a PC-style menu across the top of the display.

	b. Go to the Utilities menu in the menu bar and select Option 
           Installation.

	c. Follow the on-screen instructions to enter the alphanumeric 
	   key number exactly as it is printed on the rear-panel label.

  The TDSHT3v1-3 application is now ready for use. See "Starting the Application".


4.2 TDSHT3v1-3 (DTG Distribution)V3.3.0 

  The Sink and Cable tests require DTG Patterns on the DTG at -
  C:\TekApplications\TDSHT3v1-3 sub-folder. Install the DTG Pattern 
  files on the Data Timing Generator (DTG 5274/5334).
  
  If the DTG Pattern files are not installed on the DTG hard disk, perform the 
  following steps to install it from the Optional Applications Software on a 
  Windows-Based Oscilloscope Compact disc (CD-ROM):

  i. If the keyboard is not installed, connect it to the oscilloscope rear panel
     (the optional-accessory keyboard plugs into the USB connector).

  ii. Power on the DTG to start Windows.

  iii. Install the optional applications software CD in the CD-ROM reader 
       of the DTG.

  iv. The autorun utility will start the installation program. If the autorun 
      utility does not start up automatically, browse to the CD-ROM and 
      double-click launch.exe.

  v. Click 'HDMI Compliance Test(1.3)'.

  vi. Click 'DTG INSTALL'. This will install the DTG Pattern files at - 
      C:\TekApplications\TDSHT3v1-3 sub-folder on the DTG.        

================================================================================

5. Starting the Application

- To start an application, select File > Run > , 
  App > , or Analyze >  from the menu bar of the oscilloscope.


================================================================================

6. Contents of Distribution 

- TDSHT3v1-3 (HDMI Compliance Test Software (1.3) Software

- Sun Microsystems' Java Runtime Environment (JRE) 1.4.2_02

- TDSHT3v1-3 Online help, the PDF of the online help, and  Quick Start User Manual
  (English and Japanese)

================================================================================

7. Contact Tektronix
 
For any assistance or feedback on the TDSHT3v1-3, please send an email to: 
- [email protected] or
- [email protected] 

---End of File---