Service Manuals, User Guides, Schematic Diagrams or docs for : Tektronix TDS7000 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 Applications 04_DDM2 readme

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Preview not available!
Sorry, no preview image available for this document.
Possible reasons are : this is not a PDF document, it is password protected or the file is partially corrupted.
We are working to fix the issue.
You can still download the full file from the link below and it will be viewable.



>> Download readme documenatation <<

Text preview - extract from the document
Readme.txt file

Date: 08 Dec 2006
Product: TDSDDM2 (Disk Drive Measurements 2).
Version: 3.0.1

This file contains more up-to-date information than will be found
in the TDSDDM2.pdf or TDSDDM2.hlp files. Installation instructions
and model support information in this file supercedes the help and
PDF files.

===============================================================

What is in this Readme File:

1. System Requirements
2. Contents of Distribution
3. New Features
   -V1.2.0
   -V1.2.1
   -V1.2.2
   -V1.2.3
   -V1.3.0
   -V1.3.1
   -V1.3.2
   -V3.0.0
   -V3.0.1
4. Known Problems
5. Installation
6. Contact Information

===============================================================
1. System Requirements

- TekScope Software version required for this release:
         Product           SW Version
    ================    ================
    DPO70404, DPO70604  2.0.0 or above
    DPO70804, DSA70404
    DSA70604, DSA70804
    DPO7054, DPO7104
    DPO7254

    TDS7054, TDS7104	2.2.0 or above
    TDS7154, TDS7254
    TDS7404, CSA7154
    CSA7404

    TDS7254B, TDS7404B  3.0.0 or above
    TDS7154B, TDS7704B
    CSA7404B

    TDS5034, TDS5054    1.0.9 or above
    TDS5104,

    TDS5034B, TDS5054B  2.0.0 or above
    TDS5104B

    TDS6604B, TDS6804B  4.0.1 or above

    TDS6124C, TDS6154C  5.0.0 or above


- P6247, P6248, or P7330 Differential Probes are recommended for connecting the
  Read Signal input to an oscilloscope channel.

- Sun Microsystem's Java Runtime Environment (JRE) version 1.4.2_04 is
  required for this release.

- Disk space requirements:
  8.5MB of free disk space to install and operate this application.

- Note that while TDSDDM2 will run on two channel instruments the "Sector" mode
  should not be used on those instruments since it requires three channels.

- Refer to the TDSDDM2 manual for more requirements.

- The JRE will be installed when TDSDDM2 is installed. If the JRE is deleted
  then re-install TDSDDM2

- This software download offers Five (5) Free Trials for evaluation. Once the
  five free trials are exhausted, a software security key may be purchased from
  Tektronix to permanently enable the software application on your oscilloscope.

===============================================================
2. This Distribution includes these files:
C:\Program Files\TekApplications\TDSDDM2
 ddm2.jar
 InstGpibNative.dll
 Readme.txt
 SRM.xml
 starthelp.bat
 tdsddm2.bat
 TDSDDM2.cnt
 TDSDDM2.GID
 TDSDDM2.HLP
 TDSDDM2.pdf
 tdsddm2ctrl.c
 version.ini

C:\TekApplications\tdsddm2\waveforms:
 asperity.wfm
 baselineShift.wfm
 ovhisig.wfm
 ovlosig.wfm
 taapw50.wfm
 x9x4x1.wfm

===============================================================

3. New Features

v3.0.1

- Support for the latest DPO Tektronix instruments.
- Fixed out of memory error with 50M RL on DPO7254.

---------------------------------------------------------------

v3.0.0

- Support for DPO7000 and DSA/DPO70000 instruments.
- Update to Sun Microsystem's Java (TM) Runtime Environment (JRE)
  version 1.4.2_04 incorporated.

---------------------------------------------------------------

V1.3.2

- Provide TDS6604B and TDS6804B support.

---------------------------------------------------------------

V1.3.1

- Correction to this readme file only. No software change from V1.3.0.
  Corrected list of the TekScope Software Product models supported
  by TDSDDM2.

---------------------------------------------------------------

V1.3.0

- Update to support XGA display resolution.

---------------------------------------------------------------

V1.2.3

- Update to Sun Microsystem's Java (TM) Runtime Environment (JRE)
  version 1.2.2-14 incorporated.

---------------------------------------------------------------

V1.2.2

- Enhanced instGpibNative.dll [v4.1.0.1], for TekVisa

---------------------------------------------------------------

V1.2.1

- Qualified on Windows2000 (TM) Professional Operating System
  and backward compatible with Windows98 (TM) and WindowsME
  (TM) OS.

- Added Start menu shortcuts for OLH and the PDF
    Start > Programs> TekApplications> TDSDDM2> Help (PDF Version)
    Start > Programs> TekApplications> TDSDDM2> Help

---------------------------------------------------------------

V1.2.0

- The range of the filters is displayed on the Filter panel.

- For the filters an Update button was added to update the filter ranges
  after the sample rate of the instrument has been changed.

- The behavior of the file chooser has been improved.

- A GPIB command was added to set/query the Asperity threshold.

===============================================================

4. Known Problems

V3.0.0

- Unchanged from V1.3.2

---------------------------------------------------------------

V1.3.2

- Unchanged from V1.3.1

---------------------------------------------------------------

V1.3.1

- Unchanged from V1.3.0

---------------------------------------------------------------

V1.3.0

- Unchanged from V1.2.3

---------------------------------------------------------------

V1.2.3

- Unchanged from V1.2.2

---------------------------------------------------------------

V1.2.2

- Unchanged from V1.2.1
- If the application fails to restore the Oscilloscope settings on exit, 
  then make certain the folder "C:\Windows\temp" exists.

---------------------------------------------------------------

V1.2.1

- Unchanged from V1.2.0

- The "Hide" or "Close" Button/Icon can intermittently remain in foreground
  when TekScope application goes to full window and displays the "App"
  button. If this occurs, click anywhere in TekScope Application to bring
  TekScope application forward.

---------------------------------------------------------------

V1.2.0

- Due to a bug in Sun's JRE v 1.2.2 dragging a dialog box to the 2nd 
  monitor causes the contents of the window to be displayed on the
  wrong monitor. 

- The possibility exists that if the same reference memory is selected to
  store more than one waveform the application might hang since only one 
  waveform may be stored in a ref.  The work around is to ensure that each 
  reference memory is used for only one waveform.

===============================================================

5. Installation

Normally, the TDSDDM2 application resides on the hard drive of your 
oscilloscope. If the application is not installed on hard disk perform 
the following steps to install the application from the Optional 
Applications Software on a Windows-Based Oscilloscope Compact disc (CD-ROM.)

  1. If the keyboard is not installed, connect it to the oscilloscope rear
     panel (the optional-accessory keyboard plugs into the DDM connector).
  2. Power on the oscilloscope to start Windows.
  3. Install the optional applications software CD in the CD-ROM/DVD Drive 
     of the oscilloscope.
  4. The AutoOpen utility will start the installation program.
  5. Select the option 'Install Products'.
  6. Select the option 'Disk Drive Measurement'.
  7. Select the option 'INSTALL NOW'.
  8. Follow the instructions given by the InstallShield Wizard. If Java
     Run-time Environment (JRE 1.4.2_04) software is not previously installed 
     then the InstallShield Wizard will prompt for installing it. 
     Click "Yes" when prompted for installing JRE 1.4.2 and the InstallShield 
     will install it. 
     The oscilloscope must reboot to complete the installation process.
  9. You will need to enter the authorized Option Installation Key to enable
     the application. The key is specific to the serialized oscilloscope and
     options for which it was purchased.

     Do not enter this key until all application software that you have
     purchased has been installed. To enter the key number, follow these steps:
	a. If the oscilloscope powered on in the toolbar mode (default), select
	   the Menu button (upper right corner of the display) to put the
	   oscilloscope into menu-bar mode. In menu-bar mode you should see a
	   PC-style menu across the top of the display.
	b. Go to the Utilities menu in the menu bar and select Option 
           Installation.
	c. Follow the on-screen instructions to enter the alphanumeric key
	   number exactly as it is printed on the rear-panel label. 

 NOTE: 
     If the AutoOpen utility fails to start, then Select the My Computer icon.
     In the Exploring My Computer window, select the CD-ROM (for example, D:)
     drive.
     Select the file Launch.exe to start the installation program. Complete 

===============================================================
6. Contact Information

- Telephone:
	Contact your local Tektronix Representative at 1-800-833-9200 
 		Sales support,     	select option 1
		Service support,	select option 2
		Technical support, 	select option 3



-WEB:
   	http://www.tektronix.com/Measurement/scopes/index.html

	Click on "Software & Drivers" under the "Resources For You" set of
        links on the left.

---End of File---



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo