Service Manuals, User Guides, Schematic Diagrams or docs for : Tektronix TDS7000 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 Documents HT3-1.2a_Documentation TDSHT3_Quick_Ref_Card_SinkTest

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
TDSHT3_Quick_Ref_Card_SinkTest


>> Download TDSHT3_Quick_Ref_Card_SinkTest documenatation <<

Text preview - extract from the document
Getting Started with TDSHT3                                      4. The software remotely controls the DTG and AWG,        6. To configure and test the GPIB connection to the DTG,
                                                                     which must be connected by a National Instruments         click Signal Sources. The Signal Sources Setup dialog
You can use this side of the quick reference card to get             GPIB-USB-B. To connect the DUT, click Tests >             box appears.
started with the Sink Jitter Tolerance test procedure. The           Connect.
other side contains a complete menu tree for the TDSHT3
HDMI Compliance Test Software.

    NOTE. For additional procedures, refer to the
    TDSHT3 Quick Start User Manual. For
    complete operating instructions, refer to the
    online help.


TDSHT3 HDMI Compliance Test Software enables
unprecendented efficiency by providing a comprehensive           5. Make the connections as follows:
range of tests, including Jitter Tolerance.                                                                                7. To run the test successfully, ensure that the Bus Timing
                                                                 To find the device tolerance limit                           parameter is set to 2 usec on your GPIB board
Sink Jitter Tolerance                                                                                                         configuration.
This test allows you to confirm that the maximum allowed                                                                   8. Click Run Test to perform the test. The TDSHT3
TMDS clock jitter is supported by the Sink DUT.                                                                               HDMI Compliance Test Software sets up the
                                                                                                                              oscilloscope and conducts the test. Follow the
You will need one supported oscilloscope, two differential                                                                    instructions in the dialog box. Depending on your
probes, one digital timing generator (DTG), one arbitrary                                                                     answer, a series of dialog boxes may prompt you for
waveform generator (AWG), one DC power supply, 12                                                                             your input.
SMA cables, two bias-tees, one cable emulator, one GPIB
controller, one TPA-R-DI, and one TPA-R-TDR.                                                                               9. If you successfully run the test, the software calculates
                                                                                                                              the jitter values and displays the results. The software
Follow these steps:                                                                                                           makes Result available automatically and displays the
                                                                                                                              result summary, the eye diagram plot, and the clock jitter
1. On the menu bar, click Tests > Select > Sink.                                                                              plot. You can also view the report configuration details
2. In the differential tests pane, select the Jitter Tolerance                                                                in the result pane.
    check box.




                                                                 To measure the parameters




3. To change the configuration settings, click Tests >                                                                     10. In the result summary pane, click Result Details to
    Configure. For most tests, you can use the factory                                                                         display the results of the tests.
    default configuration. However, you can change the
    values by using the virtual keyboard or the general
    purpose knob on the oscilloscope front panel. Using the
    File menu, you can also restore the factory defaults or
    save and recall your own configuration settings.




For up-to-date information on Tektronix oscilloscope             To order along with oscilloscope:
solutions for HDMI Compliance Test Software, access
                                                                 H Opt. HT3 - HDMI Compliance Test Software
the www.tektronix.com Web page.
                                                                 To order an upgrade for an existing oscilloscope:
TDSHT3 Ordering Information
This software supports the TDS6000B, TDS6000C,                   H TDS6000B - Order TDS6BUP - Opt. HT3
TDS7254/B, TDS7404/B, CSA7404/B, TDS7704B, and                   H TDS7000/B - Order TDS7UP/7BUP - Opt. HT3
DPO/DSA70000 series of oscilloscopes. Refer to the               H CSA7000/B - Order TDS7UP/7BUP - Opt. HT3
Optional Applications Software on Windows-Based
Oscilloscopes Installation Manual for a list of specific         Recommended Accessories
models. The applications CD includes a PDF file of the
online help.                                                     Oscilloscopes
                                                                 H 16M Record Length/Ch - Opt. 4M or more (for Eye
                                                                    Diagram and Jitter tests)
                                                                 H Serial Trigger - Opt. ST (for Inter-pair Skew tests)
                                                                 HDMI Pattern Sources
                                                                 H Jitter Generation - AWG710B (for Sink tests)
                                                                 H Test Pattern Generation - DTG5274 and DTGM30 for
                                                                   Sink Tests (three required)
                                                                 TDR Tests
                                                                 H Oscilloscope - TDS8000B with 80E03 and 80E04
                                                                   modules
                                                                                                                              TDSHT3
                                                                 Probes                                                       HDMI Compliance Test Software
                                                                 H Differential Probes - P6330, P7330, P7350 (two probes      Reference
                                                                    required), and P7380
                                                                 H Active Probes - P7240 and above (two probes required)      Sink Test
                                                                 H Probe Positioner - PPM100 Flexible Arm Probe Posi-
                                                                    tioner
                                                                 Test Fixtures
                                                                 H Plug type - HDMI TPA-P adapter set - 013-A013-50
                                                                 H Receptacle type - HDMI TPA-R adapter set -
                                                                     013-A012-50




                                                                                                                            www.tektronix.com
                                                                                                                            *P071196001*
                                                                                                                            071-1960-01
TDSHT3 Menu Tree
                                    Recall Default
                                    Recall
                                    Save
                        File        Recall Recent      Position Eye Mask in Center
                                    Preferences        Acquisition Alert Message
                                    Minimize                                                         Pulse Width
                                                       Trigger (Rise/Fall Time or Over/Undershoot)
                                    Exit                                                             Edge Trigger

                                                                                                     Eye Diagram
                                                       Source                                        Duty Cycle
                                    Select             Sink                                          Rise Time
                                                       Cable                                         Fall Time
                                                                                                     Clock Jitter
                                                                                                     Over/Undershoot VH
                                                       Source                                        Over/Undershoot VL
                                                                                                     InterPair Skew (ClockData Tests)
                                                                                                     InterPair Skew (DataData Tests)
                                                                                                     IntraPair Skew
                                                                                                     Low Amplitude +
                        Tests       Configure                                                        Low Amplitude

                                                                                                     Min/MaxDiff Swing Tolerance
                                                       Sink                                          Jitter Tolerance
                                                                                                     IntraPair Skew

                                                       Cable                                         Eye Diagram
                                    Connect

                                    View Waveform


                                    Summary
                        Results     Details
                                                       Define Test Template
                        Utilities   Report Generator   Define Report Layout
                                    Deskew             Generate Report

                        Help        Help Topics
                                    About TDSHT3




Copyright  Tektronix, Inc.



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo