Service Manuals, User Guides, Schematic Diagrams or docs for : Tektronix TDS7000 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 Documents HT3-1.2a_Documentation TDSHT3_Quick_Ref_Card_SourceTest

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
TDSHT3_Quick_Ref_Card_SourceTest


>> Download TDSHT3_Quick_Ref_Card_SourceTest documenatation <<

Text preview - extract from the document
Getting Started with TDSHT3                                   4. To connect the DUT, click Tests > Connect.                  8. If you have run the tests successfully, the software
                                                                                                                                 makes Result available automatically and displays the
You can use this side of the quick reference card to get                                                                         eye diagram plot and the clock jitter plot. You can also
started with the Source Clock-Data Tests Select All test                                                                         view both the result summary of the test and the report
procedure. The other side contains a complete menu tree for                                                                      configuration in the result pane.
the TDSHT3 HDMI Compliance Test Software.

    NOTE. For additional procedures, refer to the
    TDSHT3 Quick Start User Manual. For
    complete operating instructions, refer to the
    online help.
                                                              5. Make the connections as follows:

TDSHT3 HDMI Compliance Test Software enables
unprecendented efficiency by providing a comprehensive
range of tests, including Jitter Tolerance.
                                                                                                                             9. In the result summary pane, click Result Details to
Source Clock-Data Tests Select All                                                                                               display the results of the tests.
This option enables you to run the Eye Diagram, Duty
Cycle, Rise Time, Fall Time, Clock Jitter, Over/Undershoot
V-H, Over/Undershoot V-I, and Inter-Pair Skew test
simultaneously.
You will need one supported oscilloscope, two differential
probes, one DC power supply 3.3 V, one EDID emulator,
and one TPA-P-DI fixture.
Follow these steps:
1. On the menu bar, click Tests > Select > Source.                                                                           10. In the Result Details dialog box, click Result Statistics
2. In the clock-data tests pane, click Select All.                                                                               to display statistics based on the tests.


                                                              6. Ensure that your signal in the oscilloscope display is
                                                                  similar to the sample signal. Click View Waveform to
                                                                  display a sample of the expected signal. If the displays
                                                                  are not similar, go back and check your configuration
                                                                  and connections.



3. To change the configuration settings, click Tests >
    Configure. For most tests, you can use the factory                                                                       The software calculates statistics for each selected test, and
    default configuration. However, you can change the                                                                       logs the statistics on a cycle-by-cycle basis in a fairly large
    values by using the virtual keyboard or the general                                                                      waveform. The standard statistics are for the Maximum,
    purpose knob on the oscilloscope front panel. Using the                                                                  Minimum, Mean, Standard Deviation, and Population.
    File menu, you can also restore the factory defaults or
    save and recall your own configuration settings.
                                                              7. Click Run Test to perform the test. The TDSHT3
                                                                  HDMI Compliance Test Software sets up the
                                                                  oscilloscope and the test runs displaying a progress
                                                                  indicator.




For up-to-date information on Tektronix oscilloscope          To order along with oscilloscope:
solutions for HDMI Compliance Test Software, access the
www.tektronix.com Web page.                                   H Opt. HT3 - HDMI Compliance Test Software
                                                              To order an upgrade for an existing oscilloscope:
TDSHT3 Ordering Information
                                                              H TDS6000B - Order TDS6BUP - Opt. HT3
This software supports the TDS6000B, TDS6000C,
TDS7254/B, TDS7404/B, CSA7404/B, TDS7704B, and                H TDS7000/B - Order TDS7UP/7BUP - Opt. HT3
DPO/DSA70000 series of oscilloscopes. Refer to the            H CSA7000/B - Order TDS7UP/7BUP - Opt. HT3
Optional Applications Software on Windows-Based
Oscilloscopes Installation Manual for a list of specific      Recommended Accessories
models. The applications CD includes a PDF file of the
online help.                                                  Oscilloscopes
                                                              H 16M Record Length/Ch - Opt. 4M or more (for Eye
                                                                 Diagram and Jitter tests)
                                                              H Serial Trigger - Opt. ST (for Inter-pair Skew tests)
                                                              HDMI Pattern Sources
                                                              H Jitter Generation - AWG710B (for Sink tests)
                                                              H Test Pattern Generation - DTG5274 and DTGM30 for
                                                                Sink Tests (three required)
                                                              TDR Tests
                                                              H Oscilloscope - TDS8000B with 80E03 and 80E04
                                                                modules                                                         TDSHT3
                                                              Probes                                                            HDMI Compliance Test Software
                                                              H Differential Probes - P6330, P7330, P7350 (two probes           Reference
                                                                 required), and P7380
                                                              H Active Probes - P7240 and above (two probes required)
                                                                                                                                Source Test
                                                              H Probe Positioner - PPM100 Flexible Arm Probe Posi-
                                                                 tioner
                                                              Test Fixtures
                                                              H Plug type - HDMI TPA-P adapter set - 013-A013-50
                                                              H Receptacle type - HDMI TPA-R adapter set -
                                                                  013-A012-50




                                                                                                                              www.tektronix.com
                                                                                                                              *P071195901*
                                                                                                                              071-1959-01
TDSHT3 Menu Tree
                                    Recall Default
                                    Recall
                                    Save
                        File        Recall Recent      Position Eye Mask in Center
                                    Preferences        Acquisition Alert Message
                                    Minimize                                                         Pulse Width
                                                       Trigger (Rise/Fall Time or Over/Undershoot)
                                    Exit                                                             Edge Trigger

                                                                                                     Eye Diagram
                                                       Source                                        Duty Cycle
                                    Select             Sink                                          Rise Time
                                                       Cable                                         Fall Time
                                                                                                     Clock Jitter
                                                                                                     Over/Undershoot VH
                                                       Source                                        Over/Undershoot VL
                                                                                                     InterPair Skew (ClockData Tests)
                                                                                                     InterPair Skew (DataData Tests)
                                                                                                     IntraPair Skew
                                                                                                     Low Amplitude +
                        Tests       Configure                                                        Low Amplitude

                                                                                                     Min/MaxDiff Swing Tolerance
                                                       Sink                                          Jitter Tolerance
                                                                                                     IntraPair Skew

                                                       Cable                                         Eye Diagram
                                    Connect

                                    View Waveform


                                    Summary
                        Results     Details
                                                       Define Test Template
                        Utilities   Report Generator   Define Report Layout
                                    Deskew             Generate Report

                        Help        Help Topics
                                    About TDSHT3




Copyright  Tektronix, Inc.