Service Manuals, User Guides, Schematic Diagrams or docs for : Tektronix TDS7000 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 Documents HT3-1.3_Documentation TDSHT3_Source_Reference

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
TDSHT3_Source_Reference


>> Download TDSHT3_Source_Reference documenatation <<

Text preview - extract from the document
Getting Started with TDSHT3                                     4. To connect the DUT, click Tests > Connect.                  8. If you have run the tests successfully, the software
                                                                                                                                   makes Result available automatically and displays the
You can use this side of the quick reference card to get                                                                           eye diagram plot and the clock jitter plot. You can also
started with the Source Clock- -Data Tests Select All test                                                                         view both the result summary of the test and the report
procedure. The other side contains a complete menu tree for                                                                        configuration in the result pane.
the TDSHT3 HDMI Compliance Test Software.

    NOTE. For additional procedures, refer to the
    TDSHT3 Quick Start User Manual. For
    complete operating instructions, refer to the
    online help.
                                                                5. Make the connections as follows:

TDSHT3 HDMI Compliance Test Software enables
unprecedented efficiency by providing a comprehensive
range of tests, including Jitter Tolerance. Start the
application by using Analyze > HDMI Compliance Test                                                                            9. In the result summary pane, click Result Details to
Software(1.3) or App > HDMI Compliance Test                                                                                        display the results of the tests.
Software(1.3).

Source Clock- -Data Tests Select All
This option enables you to run the Eye Diagram, Duty
Cycle, Rise Time, Fall Time, and Clock Jitter
simultaneously.
You will need one supported oscilloscope, two differential
probes, one DC power supply 3.3 V, one EDID emulator,
and one HDMI EFF-   -TPA- fixture.
                         -P
Follow these steps:                                                                                                            10. In the Result Details dialog box, click Result Statistics
                                                                                                                                   to display statistics based on the tests.
1. On the menu bar, click Tests > Select > Source.
               -data tests pane, click Select All.
2. In the clock-




                                                                6. Ensure that your signal in the oscilloscope display is
                                                                    similar to the sample signal. Click View Waveform to
                                                                    display a sample of the expected signal. If the displays
                                                                    are not similar, go back and check your configuration
                                                                    and connections.                                           The software calculates statistics for each selected test, and
3. To change the configuration settings, click Tests >                                                                         logs the statistics on a cycle- -cycle basis in a fairly large
                                                                                                                                                             -by-
    Configure. For most tests, you can use the factory                                                                         waveform. The standard statistics are for the Maximum,
    default configuration. However, you can change the                                                                         Minimum, Mean, Standard Deviation, and Population.
    values by using the virtual keyboard or the general
    purpose knob on the oscilloscope front panel. You can
    also restore the factory defaults or save and recall your
    own configuration settings.




                                                                7. Click Run Test to perform the test. The TDSHT3
                                                                    HDMI Compliance Test Software sets up the
                                                                    oscilloscope and the test runs displaying a progress
                                                                    indicator.




For up-to-date information on Tektronix oscilloscope            Recommended Accessories
solutions for HDMI Compliance Test Software, access the
www.tektronix.com Web page.                                     Oscilloscopes
                                                                H 16 M Record Length/Ch: Opt. 4 M or more (Eye
TDSHT3 Ordering Information                                        Diagram and Jitter tests)
This software supports the TDS6000B, TDS6000C,                  HDMI Pattern Sources
TDS7254/TDS7254B, TDS7404/TDS7404B, CSA7404/
CSA7404B, TDS7704B, and DPO70000 series of                      H Jitter Generation: AWG7102/AWG710/AWG710B/
oscilloscopes. Refer to the Optional Applications Software        AFG3000 (minimum two channel AFG) for Sink tests
on Windows-Based Oscilloscopes Installation Manual for a        H Test Pattern Generation: DTG5274/DTG5334,
list of specific models. The applications CD includes a PDF       DTGM30 (three required), and DTGM32 (one required
file of the online help.                                          for AFG3000/AWG710/AWG710B) for sink tests
To order along with oscilloscope:                               TDR Tests
H Opt. HT3 - HDMI Compliance Test Software
              -                                                 H Oscilloscope: TDS8200B/DSA8200 with 80E03 and
                                                                  80E04 modules
To order an upgrade for an existing oscilloscope:
                                                                Probes
H TDS6000B - Order TDS6BUP - Opt. HT3
                 -               -
                                                                H Differential Probes: P7313SMA for both single-ended
H TDS7000/B - Order TDS7UP/7BUP - Opt. HT3
                  -                    -
                                                                   and differential measurements. P7350SMA can be used
H CSA7000/B - Order TDS7UP/7BUP - Opt. HT3
                  -                    -                           for differential tests of limited resolutions.
H DPO70000 - Order DPO7UP - Opt. HT3
                -              -                                H Active Probes: P7240 (two probes) for single ended
To order an upgrade from HDMI 1.2a to HDMI 1.3a                    measurements using old fixtures.
compliance test software:                                       H Probe Positioner: PPM100 Flexible Arm Probe Posi-
                                                                                                                                  TDSHT3
                                                                   tioner.                                                        HDMI Compliance Test Software
H   TDS6000B - Order TDS6BUP - Opt. HT23
             -                 -
                                                                Test Fixtures                                                     Reference Source Test
H   TDS7000/B - Order TDS7UP/7BUP - Opt. HT23
              -                    -
H   CSA7000/B - Order TDS7UP/7BUP - Opt. HT23
               -                    -                           H Plug type: EFF-   -HDMI-  -TPA- available from Efficere
                                                                                                  -P,
                                                                    Technologies
H   DPO70000 - Order DPO7UP - Opt. HT23
             -               -
                                                                H Receptacle type: EFF-    -HDMI-  -TPA- available from
                                                                                                         -R,
                                                                    Efficere Technologies
    NOTE. You will be provided with two
    TDSHT3 applications, one supporting                         H Receptacle type: HDMI TPA- adapter set -
                                                                                                  -R          -
    CTS 1.2a specification, displayed as                            013--A012- (can be used for limited resolution)
                                                                               -50
    TDSHT3, and the other for CTS 1.3a                          H Plug type: HDMI TPA- adapter set - 013-
                                                                                            -P             - -A013-  -50
    specification, displayed as TDSHT3v1.3. Both                    (can be used for limited resolution)
    applications can be loaded onto the
    oscilloscope, but you can run only one
    application at a time.




                                                                                                                                www.tektronix.com
                                                                                                                                *P071195902*
                                                                                                                                071-1959-02
TDSHT3 Menu Tree
                                     Recall Default
                                     Recall
                                     Save
                         File        Recall Recent      Position Eye Mask in Center
                                     Preferences        Acquisition Alert Message
                                     Minimize
                                     Exit

                                                                                      Eye Diagram
                                                        Source                        Duty Cycle
                                     Select             Sink                          Rise Time
                                                        Cable                         Fall Time
                                                                                      Clock Jitter
                                                                                      Inter-- Pair Skew (Data-- Data Tests)
                                                         Source                       Intra-- Pair Skew
                                                                                      Low Amplitude +
                                                                                      Low Amplitude 



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo