Text preview - extract from the document
                                   *TB 9-6625-2295-35
      DEPARTMENT OF THE ARMY TECHNICAL BULLETIN
        CALIBRATION PROCEDURE FOR
           OSCILLOSCOPE, OS-288/G
           (TEKTRONIX, TYPE 2465B)
                     AND
     TEKTRONIX, TYPES 2465B OPT46 AND 2467B
                    Headquarters, Department of the Army, Washington, DC
                                      21 October 2002
                            Approved for public release, distribution is unlimited.
                 REPORTING OF ERRORS AND RECOMMENDING IMPROVEMENTS
        You can improve this manual. If you find any mistakes or if you know of a way to improve these
        procedures, please let us know. Mail your letter, DA Form 2028 (Recommended Changes to
        Publications and Blank Forms), or DA Form 2028, directly to Commander, U.S. Army Aviation
        and Missile Command, ATTN: AMSAM-MMC-MA-NP, Redstone Arsenal, AL 35898-5000. A
        reply will be furnished to you. You may also provide DA Form 2028 information to AMCOM via
        e-mail, fax, or the World Wide Web. Our FAX number is: DSN 788-6546 or Commercial 256-
        842-6546. Our e-mail address is: [email protected]. Instructions for sending an
        electronic 2028 may be found at the back of this manual. For the World Wide Web, use:
        https://amcom2028.redstone.army.mil.

                                                                                                     Paragraph   Page
 SECTION                I. IDENTIFICATION AND DESCRIPTION
                           Test instrument identification ............................                   1        2
                           Forms, records, and reports................................                   2        2
                           Calibration description........................................               3        2
                       II. EQUIPMENT REQUIREMENTS
                           Equipment required............................................                4        4
                           Accessories required...........................................               5        4
                     III.   CALIBRATION PROCESS
                            Preliminary instructions.....................................                6         4
                            Equipment setup ................................................             7         5
                            Vertical gain.......................................................         8         6
                            Triggering ..........................................................        9        10
                            Timing ...............................................................      10        14
                            Bandwidth ..........................................................        11        20
                            Calibrator...........................................................       12        21
                            Parametric measurements .................................                   13        22
                            Final procedure ..................................................          14        23




_____ _____
   *This bulletin supersedes TB 9-6625-2295-35, dated 13 January 1997.
TB 9-6625-2295-35

                                                                                              Paragraph   Page
    SECTION         IV. MENU CALIBRATION PROCESS
                        Prelim inary instructions.....................................           15        23
                        Equipment setup ................................................         16        24
                        Power supply ......................................................      17        25
                        DAC REF and input capacitance..........................                  18        27
                        CAL 01 horizontal...............................................         19        27
                        CAL 02 vertical...................................................       20        33
                        CAL 03 triggering ...............................................        21        35
                        CAL 06 vertical transient response .....................                 22        36
                        CAL 09 parametric measurements......................                     23        39
                        Final procedure ..................................................       24        40


                                       SECTION I
                            IDENTIFICATION AND DESCRIPTION

1. Test Instrument Identification. This bulletin provides instructions for the
calibration of Oscilloscope, OS-288/G (Tektronix, Type 2465B), and Tektronix, Types
2465B OPT 46 and 2467B. The manufacturer's manual was used as the prime data
source in compiling these instructions. The equipment being calibrated will be referred
to as the TI (test instrument) throughout this bulletin.

   a. Model Variations.                 Tektronix, Type 2465B OPT46 and 2467B OPT10 are
equipped with an IEEE bus.
   b. Time and Technique. The time required for this calibration is approximately 6
hours, using the dc and low frequency technique.
2. Forms, Records, and Reports

   a. Forms, records, and reports required for calibration personnel at all levels are
prescribed by TB 750-25.
   b. Adjustments to be reported are designated (R) at the end of the sentence in which
they appear. Report only those adjustments made and designated with (R).
3. Calibration Description. TI parameters and performance specifications which
pertain to this calibration are listed in table 1.
                                         Table 1. Calibration Description
       Test instrument parameters                            Performance specifications
      Vertical gain CH1 and CH2          Range: 2 mV/div to 5 V/div
                                         Accuracy: 