Changing Instrument Settings

        This section describes how to change the date and time settings,
        printer settings, and the GPIB and RS-232 parameters. This section
        describes how to display a screen that details the CTS850 SDH/PDH
        Test Set configuration. You will also find a description of how to run
        the instrument self-test in this section.


Viewing the Instrument Configuration
        You can display a page that describes how the CTS850 is configured
        as well as the installed options and the hardware and firmware
        revision level.
        To display the instrument configuration:


         Press Menu          Select Menu    Highlight
         Button              Page           Parameter           Select Choice
         UTILITY             INSTR CONFIG   none                none


        Table 3 48 describes the lines of the INSTR CONFIG page.

        Table 3 48:Lines of the Instrument Configuration Page

         Line                               Description
         Model                              The model number of the instrument.
         Serial Number                      The serial number of the instrument.
         Hardware Revision                  The version of hardware.
         Option Revision                    The version of options.
         Firmware Revision                  The version of firmware.
         Options                            Lists the options and number of
                                            options




CTS850 SDH/PDH Test Set User Manual                                           3 261
Changing Instrument Settings




         Table 3 48:Lines of the Instrument Configuration Page (Cont.)

          Line                                 Description
          Interface Module                     Displays which interface module is
                                               installed (supported transmit and
                                               receive rates) and wavelength of
                                               module, if optical.
          PDH Option                           Indicates whether the 2/8/34/45/140
                                               Mb/s Mux/Demux options are
                                               installed.
          Jitter Option                        Indicates whether Jitter/Wander
                                               Option is installed
          VC4 4c                               BER test of Concatenated STM 4c
                                               signal



Setting the Display Brightness
         You can set the display brightness to three levels: Low, Medium, and
         High.
         To set the display brightness:


          Press Menu         Select Menu        Highlight
          Button             Page               Parameter          Select Choice
          UTILITY            MISC SETTINGS      Display            Low
                             (see Figure 3 102) Brightness
                                                                   Medium
                                                                   High




3 262                                   CTS850 SDH/PDH Test Set User Manual
                                                Changing Instrument Settings




        Figure 3 102:The MISC SETTINGS Page


Turning the Beeper On and Off
        The CTS850 has a beeper. The beeper is used to alert you when a
        pass/fail test has completed, or when certain conditions occur. You
        can turn off the beeper if you wish.
        To turn the beeper on or off:


         Press Menu       Select Menu        Highlight
         Button           Page               Parameter        Select Choice
         UTILITY          MISC SETTINGS      Beeper           On
                          (see Figure 3 102)
                                                              Off




CTS850 SDH/PDH Test Set User Manual                                      3 263
Changing Instrument Settings




Setting the Date
         The date is used when writing files to disk, it is used to track
         measurement history, and it is used when displaying history graphs.
         To set the date:
         1. Display the current date setting as follows:


          Press Menu        Select Menu        Highlight
          Button            Page               Parameter      Select Choice
          UTILITY           MISC SETTINGS      Current Date   SET DATE


            After you select SET DATE, the CTS850 enters Edit Mode.
         2. Assign the knob by selecting Year, Month, or Day as necessary.
         3. Turn the knob to change the setting.
         4. Select CANCEL to abort any changes and exit Edit Mode.
         5. Select DONE to enter your changes and exit Edit Mode.


Setting the Time
         The time is used when writing files to disk, it is used to track
         measurement history, and it is used when displaying history graphs.
         To set the time:
         1. Display the current time as follows:


          Press Menu        Select Menu        Highlight
          Button            Page               Parameter      Select Choice
          UTILITY           MISC SETTINGS      Current Time   SET TIME
                            (see Figure 3 102)


            After you select SET TIME, the CTS850 enters Edit Mode.




3 264                                 CTS850 SDH/PDH Test Set User Manual
                                                  Changing Instrument Settings




        NOTE. While you set the time in Edit Mode, the clock stops running.

        2. Assign the knob by selecting Hour, or Minute as necessary.
        3. Turn the knob to change the setting.
        4. Select CANCEL to abort any changes and exit Edit Mode.
        5. Select DONE to enter your changes and exit Edit Mode.


Changing the Printer Setup
        The CTS850 prints to Tek DPU-411 printers, Epson-compatible
        printers, Hewlett-Packard Thinkjet printers and ASCII text printers.
        It can also print to a file on disk. The print parameters are located on
        the PRINTER SETUP page of the UTILITY menu (see Figure
        3 103). Printers are supported only by an RS-232 connection.




        Figure 3 103:The PRINTER SETUP Page


        Setting up the CTS850 for a printer consists of two steps, specifying
        the printer or file type and setting RS-232 parameters. Additionally,




CTS850 SDH/PDH Test Set User Manual                                         3 265
Changing Instrument Settings




         you can specify two lines of text to be included on any printout. The
         two lines of text identify the user name and the company name.

         Specifying the Printer or File Type
         To set the printer or file type:


          Press Menu         Select Menu       Highlight
          Button             Page              Parameter        Select Choice
          UTILITY            PRINTER           Printer Type     Tek DPU-411
                             SETUP
                                                                Epson
                                                                Thinkjet
                                                                To Disk
                                                                BMP Format
                                                                To Disk
                                                                Ileaf Format
                                                                To Disk
                                                                EPS Format
                                                                To Disk
                                                                ASCII


         H Select To Disk BMP Format to print a file to disk in Windows
           bitmap format.
         H Select To Disk Ileaf Format to print a file to disk in Interleaf
           image format.
         H Select To Disk EPS Format to print a file to disk in Encapsu-
           lated PostScript format.

         Setting RS-232 Parameters
         To determine the correct RS-232 settings for your printer, refer to the
         manual that came with your printer.




3 266                                   CTS850 SDH/PDH Test Set User Manual
                                                 Changing Instrument Settings




        To set the RS-232 parameters for the printer:


         Press Menu       Select Menu       Highlight
         Button           Page              Parameter        Select Choice
         UTILITY          PRINTER           Baud Rate        1200
                          SETUP
                                                             2400
                                                             4800
                                                             9600
                                            Stop Bits        1
                                                             2
                                            Parity           None
                                                             Odd
                                                             Even
                                            Flow Control     None
                                                             Software
                                                             Hardware
                                                             H/W & S/W




CTS850 SDH/PDH Test Set User Manual                                      3 267
Changing Instrument Settings




         Setting the Print User & Company Text
         You can have the CTS850 include text on a printout that identifies
         the user name and company name. Including this text is optional.
         To set the user name and company name:


          Press Menu       Select Menu       Highlight
          Button           Page              Parameter        Select Choice
          UTILITY          PRINTER           Print User &     On
                           SETUP             Company
                                                              Off
                                             User Name        EDIT TEXT
                                             Company Name     EDIT TEXT


         H The User Name and Company Name fields are 20 characters
           long. Select DONE when you are finished editing the name.


Setting Remote Control Parameters
         You can control the CTS850 using a General Purpose Interface Bus
         (GPIB) or an RS-232 connection. For information on remote control
         commands, refer to the CTS850 Programmer Manual.




3 268                                CTS850 SDH/PDH Test Set User Manual
                                                Changing Instrument Settings




        Setting the GPIB Address
        To set the CTS850 GPIB address:


         Press Menu       Select Menu       Highlight
         Button           Page              Parameter         Select Choice
         UTILITY          REMOTE            GPIB Primary      Default 4
                          CONTROL           Address (see
                                            Figure 3 104)
                                                              Inc
                                                              Dec
                                                              Offline


        H Select Default 4 to set the GPIB address to its default value.
        H Select Inc to increment the GPIB address.
        H Select Dec to decrement the GPIB address.
        H Select Offline to place the CTS850 in the offline state.
        H The maximum GPIB address value is 30. The minimum GPIB
          address value is 0.




CTS850 SDH/PDH Test Set User Manual                                        3 269
Changing Instrument Settings




         Figure 3 104:The REMOTE CONTROL Page


         Setting RS-232 Parameters
         The appropriate settings for RS-232 parameters depend on how the
         controller is set up. Refer to the user manual that came with your
         controller to determine the correct settings.




3 270                                CTS850 SDH/PDH Test Set User Manual
                                                Changing Instrument Settings




        To set the remote control RS-232 parameters:


         Press Menu      Select Menu       Highlight
         Button          Page              Parameter        Select Choice
         UTILITY         REMOTE            Baud Rate        1200
                         CONTROL
                         (see Figure
                         3 104)
                                                            2400
                                                            4800
                                                            9600
                                           Stop Bits        1
                                                            2
                                           Parity           None
                                                            Odd
                                                            Even
                                           Hardware         Off
                                           Handshake
                                                            On
                                           Software         None
                                           Handshake
                                                            Xon/Xoff
                                           Data Carrier     Off
                                           Detect
                                                            On
                                           Tx Delay         0
                                           (Seconds)
                                                            1
                                                            5
                                                            Inc
                                                            Dec




CTS850 SDH/PDH Test Set User Manual                                    3 271
Changing Instrument Settings




          Press Menu       Select Menu      Highlight
          Button           Page             Parameter         Select Choice
                                            Tx Terminator     LF
                                                              CR
                                                              CR/LF
                                                              LF/CR


         H For Tx Delay, select one of the preset choices or use Inc and Dec
           to specify a value different from the preset choices.
         H The maximum value for Tx Delay is 60. The minimum value
           is 0.


Running Instrument Self Tests
         The CTS850 provides self-contained tests that can be run any time
         you suspect the CTS850 may not be performing properly.
         The only test you might need to perform is the Power up Self Test.
         The other self tests available for selection are for servicing the
         instrument. Complete details on the self tests are located in the
         CTS 850 SDH/PDH Test Set Service manual.




3 272                                CTS850 SDH/PDH Test Set User Manual
                                                  Changing Instrument Settings




        Running the Power Up Self Test
        To run the power up self test:


         Press Menu        Select Menu       Highlight
         Button            Page              Parameter           Select Choice
         UTILITY           SELF TEST         Self Test Group     Power up
                                                                 Self Test
                                             Self Test Loop      Once
                                             Self Test Control   Run


        H Select Abort to stop a self test in progress.
        If your CTS850 fails the self test, contact the nearest Tektronix
        Service Center.




CTS850 SDH/PDH Test Set User Manual                                          3 273
Changing Instrument Settings




3 274                          CTS850 SDH/PDH Test Set User Manual



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo