Text preview - extract from the document
Reference




TDS 500B, TDS 600B & TDS 700A
Digitizing Oscilloscopes
070-9382-01
To Display a Waveform:                                                                                              To Preview a Waveform:

    Attach a probe to CH 1                             Press       Press           Adjust VERTICAL and HORIZONTAL
1   and hook the probe to your                  2      CH 1.   3   AUTOSET.   4    POSITION and SCALE.
    signal.




                                                                                                                     1   Press ZOOM.

                                                                                                                         Press Mode in the main menu. Then press Preview
                                                                                                                     2   in the side menu to turn on Dual Window Zoom.
                                                                                                                                                 Upper graticule zooms the boxed area
                                                                                                                                                             on the selected waveform.




                                                                                                                                         Lower graticule displays the selected waveform
                                                                                                                                               unzoomed with the zoomed area in box.




                                                                                                                         Use the Selected Graticule menu to select the upper
                                                                                                                         or lower waveform. Use the vertical and horizontal
                                                                                                                     3   knobs to adjust the waveform in the graticule you select.


                                                                                                                    To Capture Infrequent Events (TDS 500B & 700A Models):



                                                                                                                     Press InstaVu to toggle between InstaVu and
                                                                                                                     Normal waveform capture rates.

                                                                                                                     When in InstaVu mode:
                                                                                  Device Under                         Waveforms displayed are updated thousands of
                                                                                      Test                             times faster than normal.
                                                                                                                       Very brief changes in waveforms are captured.
                                                                                                                       Certain features, such as Limit Testing, Math
                                                                                                                       Waveforms, Zoom, and record lengths longer than
                                                                                                                       500 points, are not available.
Copyright H Tektronix, Inc., 1995. Printed in U.S.A.
To Save a Hardcopy to the File System:                                                                              To Set Up Using a Menu:
                                                                                                                                                                                           Use SHIFT for
                                                                                                                                                                                           the Alternate
                                                                                                                                                                                           (Blue) Menus




                                                                                                                     1   Press any of the front panel menu buttons.




                                                                    Press Format in the main menu, and select a
1    Press SHIFT, and then press HARDCOPY.                      2   hardcopy format from the side menu.


            Disk Drive




                                                                                                                     2   Select an item from the main (bottom) menu.


                                                                                                                                                                              The Readout Indicates The
                                                                                                                                                                              Value That You Can Adjust with
                                                                                                                                                                              the General Purpose Knob or
                                                                                                                                                                              Keypad



                                                                                                                                                                              Adjustable Menu Item Value

                                                                    Press HARDCOPY anytime to save a copy
     Press Port in the main menu, press File in the                 of the current screen to a unique file in the
 3   side menu, and then press CLEAR MENU.                      4   oscilloscope file system.                        3   Select an item from the side menu, if displayed.


 To Perform Other File System Operations:
                                                                                                                                                                             General Purpose
     H Press SAVE/RECALL WAVEFORM, and use the menu buttons to save a waveform to a file or                                                                                  Knob
       recall it from a file.

     H Press SAVE/RECALL SETUP, and use the menu buttons to save a setup to a file or recall it                                                                              Keypad
       from a file.

     H Press File Utilities in the Save/Recall Waveform, Save/Recall Setup, or Hardcopy menus to access                  Adjust menu item values using the general purpose
       utilities that create directories, copy files, and do other operations in the oscilloscope file system.       4   knob or by entering numbers on the keypad.
                                                                                                                                                                             End Your Entry by
                                                                                                                                                                             Pressing ENTER ( )
To Select a Trigger:                                                                                                                                                                         To Take Measurements Automatically:
                                                                                      Trigger Selections                                     (On some models, Ax 1 & Ax 2

                                                                                                                                                                           TYPE
                                                                                           TYPE                                                                           
                                                                                          
                                                                                                                                 CLASS                                    CLASS
                                                                                                                                                                 




                                                                           Source




                                                                                                            Define Inputs




                                                                                                                                                      Define Inputs
                                                                                       Select any one of                     Define levels High,                       Define levels High,
 1    Press TRIGGER MENU.                                                              Ch 1 thru Ch 4,
                                                                                       Line, or DC Aux
                                                                                                                             Low, or Don't Care
                                                                                                                             for Ch 1 thru Ch 4
                                                                                                                                                                       Low, or Don't Care
                                                                                                                                                                       for Ch 1 thru Ch 3

                                                                                                                                                                       Select edge for the
                                                                                                                                                                       clock (always Ch 4)
     This Symbol
                                                                                                                                                                                                                                                          Press Select Measrmnt or Snapshot in
      Indicates a                                                                                                                                                                             1   Press MEASURE.                                        2 the main menu.




                                                                                                            Define Logic




                                                                                                                                                      Define Logic
     Pop-Up Menu                                                                       Positive                                AND                                      AND




                                                                           Slope
                                                                                       Negative                                OR                                       OR                                                  Automated Measurement Selections
                                                                                                                                                                                                                                                                       Select
     Select a trigger type or
2    parameter from the main                                                                                                   NAND                                     NAND                                                                                        Measurement

     menu.
                                                                                                                               NOR                                      NOR                                                      Period    Rise Time     Delay         High        Pk