Service Manuals, User Guides, Schematic Diagrams or docs for : Tektronix aurand_sandia_scd5000_deconv

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
aurand_sandia_scd5000_deconv


>> Download aurand_sandia_scd5000_deconv documenatation <<

Text preview - extract from the document
                                                         WEP-4

          BANDWIDTH ENHANCEMENT OF SINGLE-SHOT DATA ACQUISITION SYSTEMS
                      BY DECONVOLUTION OF SYSTEM RESPONSE
                              John F. Aurand, Paul1 E. Patterson, Charles A. Frost
                     Sandia National Laboratories / High-Power ElectromagneticsDepartment
                            MS 1153, PO Box 5800 / Albuquerque, NM 87185-1153

                      Abstract                                 SCD-5000 to a host personal computer, and then
                                                               deconvolution processing. The FlT spectrum of the
Procedures have been developed [ 11 for enhancing the
                                                               acquired signal is divided by the system transfer
effective bandwidth of single-shot measurement
                                                               function, and then an inverse FFT is used to compute
systems. One procedure characterizes the transfer
                                                               the compensated timedomain input signal. If
function of the measurement system hardware, and
                                                               necessary, any one of several lowpass filtering
the other is a software compensation technique to
                                                               algorithms may then used to reduce the deconvolution
deconvolve this transfer function from the acquired
data. The example shown employs a Tektronix
SCD-5000 Transient Digitizer, with a -3 dB
bandwidth improvement of 4.5 times, to over 15 GHz.
              System Characterization
                                                               noise.



                                                                    2-10
                                                                    h




                                                                    3 -20
                                                                             0   0                           ...._ ....
                                                                                                                 ~        .......
                                                                                     _.__.__._,.._._.__...,~..........~........
                                                                                     .... ^...... . ......~.....................
Each of the components of a single-shot data                        .t

acquisition system (coaxial cabling, delay line, and
waveform recorder) is band-limited, and thus
degrades the acquired waveform. The measurement                          -50
system hardware is modeled as a cascaded
frequencydomain transfer function, and if mismatch                               0           5          10           I5             20
S parameters are assumed negligible, then the transfer                                           Frequency (GHz)
function can be formed as the ratio of the input and                     -
                                                                Fig. 1 Raw Hardware and Compensated Transfer
output signal spectra. Step timedomain excitation is              Functions of SCD-5000 Measurement System
used to characterize the entire system as one network,
permitting simple and rapid evaluation of the                  Considering the difficulties associated with
measurement hardware.                                          deconvolution of noisy data, these procedures have
The excitation step pulse is generated with a                  yielded stable, low-noise results. This success is due
Picosecond Pulse Labs 4015B pulse Generator (9 V,              to careful consideration of many signal processing
15 ps), and it is measured with two systems: the               details and fundamental hardware parameters.
single-shot SCD-5000system, and a wider-bandwidth                                            Conclusions
sampling system consisting of a Tektronix CSA-803
sampling oscilloscope with 20-GHz SD-26 Sampling               Bandwidthenhancement techmques have been
Head. This sampled waveform is taken as the input              developed for single-shot data acquisition systems.
excitation pulse, and the transfer function of the             The transfer function of the system hardware is
single-shot system is then formed as the ratio of the          characterized using step timedomain excitation, and
FFT spectra of these two waveforms.                            robust data compensation algorithms implement
                                                               frequencydomain deconvolution of that transfer
For the example system, the hardware had a -3 dB               function from the acquired data. These techniques are
bandwidth of 3.2 GHz (and a step-response risetime of          most applicable to data acquisition systems with
109 ps), and an effective bandwidth after                      waveform recorders which have signifcant
deconvolution of 15.2 GHz (and a risetime of 23 ps).           oversampling rates and well-behaved frequency
These transfer functions are shown in Fig. 1 below.            rolloff.
                Data ComDensation                                                             Reference
Once the transfer function of the single-shot system           U1   P.E. Patterson, J.F. Aurand, C.A. Frost, 15-GHz
hardware has been characterized, then subsequent                    Bandwidth Enhancement of Transient Digitizers
compensation of desired data is performed by                        In a Portable Data Acauisition System, Sandia
post-processing. This s o h a r e performs data                     National Labs Technical Report, SAND93-2280,
acquisition over an IEEE-488 (GPIB) bus f o the
                                             rm                     Feb. 1994.

                                                         282



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo