         INSTRUCTION MANUAL




                 @ 1980 Wavetek




THIS DOCUMENT CONTAINS INFORMATlON PRO-
PRIETARY TO WAVETEK AND IS SOLELY FOR IN-
STRUMENT OPERATION AND MAINTAINANCE. THE
INFORMATION IN THIS DOCUMENT IS NOT TO BE
DUPLICATED IN ANY MANNER WITHOUT THE
PRIOR APPROVAL IN WRITING OF WAVETEK.




       SAN DIEGO
      9 0 4 5 B a l b o a A v e . , S a n Dlego, Calif. 9 2 1 2 3
      P . O. B o x 6 5 1 , S a n Diego, California 9 2 1 1 2
            .                                                             Manual Revision 7/80
      Tel 7 14/279-2200                 TWX 9 1 o-335-2007          Instrument Release C-1 180
f' x' R
  n!` E




                   S'
                    fFJC
                    CNJT




          Figure i. Model 802 50 MHz Pulse Generator
1.1 THE MODEL 802                                                Double Pulse: Same as continuous, triggered and gated,
                                                                 except two pulses for each period. Time to second pulse is
The Model 802 is a 50 MHz general purpose laboratory             controlled by delay control. Double pulse at all outputs
pulse generator. The instrument gives you full control i n       except sync.
primary pulse triggering and shaping plus simultaneous TTL,
m and sync pulses. The primary pulse output has control-         External Width: External signal at trigger input determines
lability in rate, width, delay, upper level, lower level and a   output pulse width and period as shown.
choice of positive, negative or complementary outputs. The
TTL and TTL are of fixed levels and rise times that are
standard for use with compatible devices. The primary pulse
                                                                         TTL TRIG ____s-?l_-
has rise and fall times of 5 ns or less.                                  LEVEL    I I
                                                                                           I   I

The output is t30 volts with a 5OQ termination. Upper and
                                                                                           I
                                                                                           I   I
lower pulse levels are fully adjustable through +lO volts, a              PULSE
20 volt window. Termination may be internal, at the load                 OUTPUT        i-in
or both.


Single pulses or pulse pairs may be triggered; pulse width
may be trigger controlled; continuous pulses may be gated        1.2.2        Pulse Outputs
for a `
      burst' output.
                                                                 Variable Amplitude Pulse

                                                                                       0
`1.2    SPECIFICATIONS                                              E           cl
                                                                                d      $$              AMPLITUDE
                                                                    !s
                                                                                2      cs
1.2.1      Versatility                                              t2                             MAXIMUM     MINIMUM
                                                                                       0


Four Simultaneous Pulse Outputs
Fixed TTL level sync, TTL and m outputs, and variable
amplitude output pulses are available over a 5 Hz (200 ms)
to 50 MHz (20 ns) frequency range.
                                                                  1 ka
                                                                          I
                                                                         OR
                                                                               501n    +j()V   -_-_-_-_--___-_


                                                                                                _-r--r   -r---dv
                                                                   SOi    l>lka        -10V    _--------------
For optimum pulse characteristics from the variable ampli-
tude pulse output, an internal 5052 load can be selected via
a front panel control.                                           Upper and lower pulse levels are independently adjustable.
                                                                 Pulse dynamic range is +lOV when load is 5Oa terminated
Operational Modes                                                and source is not (internal 5OQ off) or vice versa. Maximum
Continuous: Generator oscillates continuously at selected        pulse amplitude is 1OV; minimum is 1V. Dynamic range
frequency.                                                       and pulse amplitude are decreased by a factor of 2 when
                                                                 source and load are 5Oa terminated. Overshoot and ringing
Triggered: Generator quiescent until triggered by external       are less than +(5% of amplitude setting +I00 mV) when ter-
TTL pulse or front panel control, then generates one pulse.      minated into 5052 at both load and source. Transition times
                                                                 are less than 5 ns.
Gated: Generator oscillates at the period rate selected by
the front panel control when gate input is high. Generator       Sync, TTL and TTL Pulses
quiescent when input is low. First cycle is synchronous          Sync pulse levels from 5Os2; TTL and TTL pulse levels into
with rising edge of gating signal.                               50!2 termination.

                                                                                                                         1-1
                                                                  Delay jitter is less than +O.l% plus 50 picoseconds. Fixed
                                                                  delay is as shown.
            SYNC, TTL



                TTL
                                                                             FIXED DELAY4            )6- 40 ns TYPICAL


                                                                              SYNC
 Transition times less than 7 ns into 5Oa termination.                                               I
                                                                                  F I X E D   DELAY+ b+- 20 ns TYPICAL

 Normal/Complement Control
                                                                             O"TP"To
 Normal pulse or its complement is selected. The normally
 quiescent and active levels are reversed in complement for-
 mat. This control affects all outputs except sync pulse.

 7.2.3    Time Domain                                             1.2.4     Input Characteristics

 Period                                                           External Trigger
 Period range is from less than 20 ns to greater than 200 ms      The circuit receiving the external trigger is TTL compatible.
 in 7 overlapping ranges. Period jitter is less than +O.l% plus   Triggering level is fixed at approximately 1.4V. Input im-
 50 picoseconds.                                                  pedance is greater than 5OOQ shunted by approximately
                                                                  33 pF. Triggering and gating occurs on the rising edge of
 Width                                                            the input signal.
 Width range is from less than 10 ns to 10 ms in 6 overlapping
 ranges. Maximum duty cycle is 70% for periods to 200 ns,         1.2.5     General
 decreasing to 50% for 20 ns periods. Width selector switch
 also has a square wave detent and a customer-specified           Environmental
 detent.." rl~ duty cycle is 50 24% to 2 E_CS period, changing    Specifications apply at 25