LED INDICATIONS FOR ERROR CONDITION
Each LED indication facilitates finding the cause of the error.
When an error is detected, each LED on the front will light up or flash when the AC Cord is plugged in.
The detected error data will not be stored in the EEPROM. This data is cleared when the AC Cord is unplugged.



                                                                                                                                       POWER LED


                                                                                          TEMP LED                  LAMP LED

                                                                                                                                                                         (Note 3) (Note 4)
          Error No.     Error Information                        ERROR DESCRIPTION                                POWER LED           TEMP LED          LAMP LED          OSD LAMP OFF
             1)       Fan1, Fan2 or Fan3    IC6302(pin6) detects the stop of FAN1, FAN2 or FAN3,                 flashes orange
                      stopped               then indicates the error when the FAN1, FAN2 or FAN3 is              once every                -                 -
                                            stopped.                                                             5 seconds
             2)       Lamp Cover open       IC6003(pin66) detects the Lamp Cover condition                       flashes orange
                                            (open or close), then indicates the error when the Lamp Cover        twice every               -                 -
                                            is open.                                                             5 seconds
             3)       Temperature Sensor    IC6302(pin4 and 5) detects open or short of the Temperature                              flashes once
                      shorted or open       Sensor (R2811) on Thermistor 1 C.B.A., then indicates the                    -           every 5 seconds         -
                                            error when Temperature Sensor is open or shorted.
                                            (The error is not detected for 1 minute after Lamp ON.)
             4)       Abnormal              IC6302(pin4 and 5) detects the temperature near                                          flashes twice
                      Temperature           the FAN1 by the Temperature Sensor (R2811) on Thermistor 1                   -           every 5 seconds         -
                                            C.B.A., then indicates the error when the temperature exceeds
                                             55 C (131 F).
                                            (The error is not detected for 1 minute after Lamp ON.)
             5)       Ballast Error         IC6003(pin19) detects the error of the Lamp, and Ballast C.B.A.,     flashes green for                     flashes once
                      (abnormal Lamp)       then indicates the error when an inner malfunction of Ballast        140 seconds.                          every 5 seconds
                                                                                                                                           -
                                            C.B.A. occurs, the Lamp voltage becomes more than 130V or            flashes red
                                            less than 30V, the Lamp is cracked, the Thermal Fuse Unit is
                                            open or the Lamp is not cooled off.
             6)       Ballast Error         IC6003(pin19) detects the error of the Lamp, then indicates the      flashes green for                     flashes twice
                      (abnormal             error when the Lamp is defective.                                    140 seconds.                          every 5 seconds
                                                                                                                                           -
                      Lamp voltage)                                                                              flashes red
             7)       Ballast Error         IC6003(pin19) detects the error of Ballast C.B.A.,                   flashes green for                     flashes 3 times
                      (abnormal             then indicates the error when the thermal fuse (F1302)               140 seconds.              -           every 5 seconds
                      temperature)          117 C (243 F) in Ballast C.B.A. is open.                             flashes red
             8)       Ballast Error         IC6003(pin19) detects the error of Ballast C.B.A.,                   flashes green for                     flashes 4 times
                      (other causes)        then indicates the error when an inner malfunction of Ballast        140 seconds.              -           every 5 seconds
                                            C.B.A. occurs.                                                       flashes red
             9)       Abnormal Voltage      IC6302(pin61) detects +33V line voltage on Main C.B.A., then         flashes orange      flashes once    flashes once
                      on 33 V line of       indicates the error when the voltage becomes less than +10V.         5 times every       every 5 seconds every 5 seconds
                      Main C.B.A.                                                                                5 seconds
            10)       Abnormal Voltage      IC6302(pin64) detects +9V line voltage on Main C.B.A., then          flashes orange      flashes twice   flashes twice
                      on 9 V line of        indicates the error when the voltage becomes less than +2V.          6 times every       every 5 seconds every 5 seconds
                      Main C.B.A.                                                                                5 seconds
            11)       Abnormal Voltage      IC6302(pin63) detects +5V line voltage on Main C.B.A., then          flashes orange      flashes 3 times flashes 3 times
                      on 5 V line of        indicates the error when the voltage becomes less than +1V.          7 times every       every 5 seconds every 5 seconds
                      Main C.B.A.                                                                                5 seconds
            12)       Abnormal Voltage      IC6302(pin7) detects +3.3V line voltage on Main C.B.A., then         flashes orange      flashes 4 times flashes 4 times
                      on 3.3 V line of      indicates the error when the voltage becomes less than +1.5V.        8 times every       every 5 seconds every 5 seconds
                      Main C.B.A.                                                                                5 seconds
            13)       Abnormal Voltage      IC6302(pin62) detects -5V line voltage on Main C.B.A., then          flashes orange      flashes 5 times flashes 5 times
                      on -5 V line of       indicates the error when the voltage becomes more than 0V.           9 times every       every 5 seconds every 5 seconds
                      Main C.B.A.                                                                                5 seconds
            14)       Abnormal Voltage      IC6302(pin60) detects +6.5V line voltage on Main C.B.A., then        flashes orange      flashes 6 times flashes 6 times
                      on 6.5 V line of      indicates the error when the voltage becomes less than +2V.          10 times every      every 5 seconds every 5 seconds
                      Main C.B.A.                                                                                5 seconds
            15)       Temperature Sensor    IC6302(pin2 and 3) detects open or short of the                                          flashes 3 times
                      shorted or open       Temperature Sensor (R2821) on Thermistor 2 C.B.A.,                           -           every 5 seconds         -
                                            then indicates the error when Temperature Sensor is open or
                                            shorted.
                                            (The error is not detected for 4 minutes after Lamp ON.)
            16)       Abnormal              IC6302(pin2 and 3) detects the temperature near                                          flashes 4 times
                      Temperature           the Lamp by the Temperature Sensor (R2821) on Thermistor 2                               every 5 seconds
                                            C.B.A., then indicates the error when the temperature exceeds                -                                   -
                                            85 C (185 F).
                                            (The error is not detected for 4 minutes after Lamp ON.)
            17)       Clogged air filter    IC6003(pin65) detects clogged air filter when the filter detection
                                                                                                                                     flashes 5 times
                                            value exceeds the standard value.                                           -            every 5 seconds         -

            18)       Request for Lamp      When accumulated Lamp operation time reaches 10,000
                      Replacement           hours, OSD (replacing the Lamp) appears on the screen.                       -                 -            lights up
                                            Note: The Lamp time is stored in EEPROM (IC6005).
             -        Forced cooling        Indicated during forced cooling.                                     flashes red for                       flashes 5 times
                                                                                                                 10 minutes                -           every 5 seconds

          Note:
          1. When any of the above errors has occurred, the LED will flash as shown above.
          2. When two or more errors have occurred at the same time, the LED will alternate light up and/or flash patterns as shown
             above every 5 seconds.
          3. Warning OSD appears when the air filter is clogged or accumulated Lamp operation time reaches 10,000 hours.
          4. LAMP OFF: The LED will flash immediately after the Lamp comes off.
          5.IC6003 and IC6302 are mounted on the Main C.B.A.
MAIN PARTS LOCATION

                                               




                   Network C.B.A.




                                                           TEMP LED
                                                               LAMP LED
                                Lamp Cover
                               Cover Switch C.B.A.
                                                                                       Network C.B.A.
                                             Optical Cover

                                                                                 POWER LED
                 Front Cover Unit                      Operation C.B.A.




                                                


         20-pin Cable




                                                                                             Projection Unit

                                                                                 Thermal Fuse Unit          Thermistor 2 C.B.A.
                                                                                                                          Fan 3
                                                                       Thermistor 1 C.B.A.
                                                                                             Air Filter
                                                                       Fan Case Unit
                                                                       (Fan 1)



                                                                                                                Fan 2
                                                                        Air Filter
         Front Jack C.B.A.                            Ballast C.B.A.            Air Filter                LCD Drive C.B.A.

           Main C.B.A.
                                           Tuner C.B.A.


   Audio                                      Fan 4
   Amp C.B.A.
                                                                                                Rear Cover


                Power C.B.A.    Rear Jack C.B.A.
                         TV/Tuner Unit
SERVICE MODE
                                                                                    Service Mode Map
In this mode, the following information can be confirmed on the
screen:                                                            Enter :
                                                                   VOLUME DOWN button + TV/VIDEO key
Service Mode (1/3)                                                 (on the front)                                            (on the remote)



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo