>> Download 477675856244221ss documenatation <<Text preview - extract from the document For Authorised Service Agents Only
Ref No: 477675856244221SS
Date 9/10/09
TECHNICAL INFORMATION Created by
Panasonic UK - Service Group
Document Category: Knowledge Base
Subject: After switch on, unit shuts down with power LED flashing 7 times
Model(s) Affected: TH-42PZ70BA, TH-42PZ70B, TH-42PZ700B, TH-42PY70E, TH-42PY70EY
Problem / Issue After switch on, unit shut s down with power LED flashing 7 times
Solution: See notes below
See page 3 for the Technical information sheet describing the cause for the B and BA variant models.
Check the SC board transistors (Q6641-6) for any failed or leaky FETs
Order Kit: TZS9EK082 which contains 10 new FETs (B1DFKM000002)
Replace the faulty transistors and update the firmware as per attached information below
Also check the condition of the soldering on the following FETs after fitting the service kit
Q6695, Q6696, Q6648, Q6649, Q6651, Q6652, Q6653, Q6654
In some cases, it has been found that some of the above FETs had no solder on their drain and source
connections whilst others may have very poor joints.
Notes on Software Updating
The attached TI sheet (page 3) covers software updating for the B version sets only.
For B versions sets, carry out the firmware update if the item > PDP-FPGA (seen on service mode opening
screen) shows less than 47.09
After software update the PDP-FPGA should be 47.09 > see picture of service mode on page 2
For BA version sets
The software update should be done using the software file: 42FM10_v4782t1_sddl_CS3.zip
Usage instructions for this software are shown on page 2:
After update, parameter PDP-FPGA will update to v 47.82
Confidential Page 1 477675856244221SSREV1
The picture below shows this TH42PZ70B model's PDP-FPGA is correct at 47.09
Update instructions for the BA software
Confidential Page 2 477675856244221SSREV1
Confidential Page 3 477675856244221SSREV1