Text preview - extract from the document
Circuit diagrams&Service manuals
                                                                 31 January '89


      VARIABLE RESISTORS
      1. Main Board

            Number                         Function

           VR147          Adjusts the OW (original width) sensor voltage
           VR148          Adjusts the OL (original length) sensor voltage
           VR201          Adjusts the ID (image density) sensor voltage
           VR202          Adjusts the AD (auto density) sensor voltage


      2. Lamp Regulator

            Number                         Function

            VR1                  Light adjustment
            VR2                  Factory Use
            VR3                  Factory Use


      3. DF Main Board

            Number                         Function

            VR101
            VR103                Belt drive motor speed adjustment

            VR104                Original entrance sensor output
                                 (IC 116-5> + 8V : With paper)
                                 (IC 116-5< + 4V : Without paper)
            VR105                Original width sensor output
                                 (IC 116-7> + 8V : With paper)
                                 (IC 116-7< + 4V : Without paper)




                                     4-5
31 January '89


DIP SWITCHES
1. Operation Panel

DIP SW 1-1

  DIP Switch         Normai                  Function

    1-1              OFF            Drum conditioning
    1-2              OFF            Free run
    1-3              OFF            Jam detection disable
    1-4              OFF            Sorter instructions
    1-5              OFF            Beeper sound disable
    1-6              OFF            Oil end check off
    1-7              OFF            Manual image density mode priority
                                    (ON: manual mode, OFF: ADS mode)
    1-8              OFF            SP Mode


2. DF Main Board

DIP SW 101

  101-1 101-2 101-3 101-4                    Function

    ON       OFF     OFF      OFF            Normal mode
    ON       OFF     OFF      ON             Free run
    ON       ON      OFF      ON             Belt speed adjustment (VR103)
    ON       ON      ON       ON             All indicators on




                                       4-6
                                                                   31 January '89


SERVICE PROGRAM MODE (SP MODE) OPERATION

The service program mode is used to check and change electrical data or
adjustment values.


1. Data Change Mode
1.   Remove the DIP SW cover and turn on DIP SWI -8 on the operation
     panel. (The Service Call indicator will start blinking.)
2.   Enter the desired SP Mode number using the numeral keys. (The entered
     number is displayed in the copy counter.)
3.   Press the Enter key. (The SP Mode number is shifted into the Magnifica-
     tion indicator and the actual data is displayed in the copy counter.)
4.   If the data is correct, press the Enter key.
5.   Enter the desired data using numeral keys, (The data entered is displayed
     in the copy counter. )
6.   Press the Enter key to place the new data in memory.
7.   Turn off DIP SW1 -8. (The Service Call indicator goes off.)


2. Data Check Mode
1. Perform steps 1 and 2 of the data change mode.
2. Press the Enter key. (The data is displayed in the Magnification indicator.)
3. Regarding SP Modes (#5, #9, #10, #50, #54 #55, #56, #57, #60),
   please refer to the following table.
4. Turn off DIP SW1 -8.

NOTE: When the machine does not receive any data, press the Clear Mode
       key or turn off the main switch.
       The Zoom key can be used to increment or decrement the SP Mode
       number.




                                         4-7
31 January '89


SERVICE PROGRAM MODE TABLE

                                                                   Factory
        Mode No.         Function                           Data                 Remarks
                                                                   Setting

 5 Exposure           Free run with exposure       O: Lamp           --      This mode is also
    Lamp OFF          lamp. Press the Start           ON                     cleared by turnlng off
    Free Run          key to start free run.       1: Lamp                   main switch, or, by
                      Press the C/S key to            OFF                    turning off DIP SW1 -8
                      stop free run.
 9 Exposure           Turns on the exposure            --            --      The main motor also
    Lamp Output       lamp and the main                                      rotates to turn the ex-
                      motor for about 10                                     posure lamp on.
                      seconds.                                               When checking the
                      Enter"1" and then press                                lamp voltage, CN3 on
                      the Enter key to turn on                               the lamp regulator
                      the exposure lamp.                                     board is used with this
                      Press the C/S key to                                   mode.
                      turn off the lamp.
 10 Drum Con-         Used to condition a              --            --      This function is the
    ditioning         new drum.                                              same as Dip SW1 -1.
                      "99" will appear in the                                Refer to NOTE 1.
                      copy counter. Press the
                      Start key to activate.
 11 All Indicators    Turns on all indicators          --            --      Refer to NOTE 1.
     ON               on the operation panel.
                      Turn off the main
                      switch, or, turn off DIP
                      SW1 -8 to stop.
 15 Auto Reset        Selects auto reset of 1      0:1 min.          o
    Time              or 3 minutes.                1:3 min.
                                                   2: None
 16 Count             Selects count up or          o: up             o
    Up/Down           count down.                  1: Down
 17 Auto Cas-         Selects Auto-Cassette        O: ON             o       Copier automatically
    sette Shift       Shift mode.                  1: OFF                    shifts to another cas-
                                                                             sette holding the same
                                                                             size paper when paper
                                                                             runs out.
 20 Feed Station      Selects feed station         O: LCT            o
     Priority (LCT)   priority.                    1:
                                                    Cassette
 21 APS Priority      Selects APS or manual.       O: APS            o       If DF is installed, APS
                                                   1: Manual                 mode is selected when
                                                                             an original is placed on
                                                                             the DF.
 22 Feed Station      Selects feed station         o: 1st            o       Refer to Note 2.
     Priority (1st,   priority.                    1: 2nd
     2nd, 3rd cas-                                 2: 3rd
     sette)


                                                 4-8
                                                                                      31 January '89



                                                               Factory
      Mode No.        Function                        Data                    Remarks
                                                               Setting

23 DF Original     Enables originals of          O:OFF           o       ADF Mode only.
    Size           various sizes to be fed       1:ON
                   from the same stack.
24 SADF Shut-      Selects the shut-off time     0:4s            o
   off Time        for SADF mode.                1:60s
28 Auto Sort       Sorl mode is automati-        0: Manual       o       Sorter and DF must be
    Mode           tally selected when           1: Auto                 installed.
                   more than 2 originals
                   are set on the DF
                   original table and the
                   entered quantity iS
                   greater than 2.
29 Fusing Unit     Selects fusing unit id-       0: No id-       0       Copier will idle for 10
    Idle           ling mode.                       ling                 seconds. Refer to
                                                 1: idling               NOTE 3.
30 Toner Suppiy    Selects toner suppiy          O: Detect       o
    Mode           mode.                            B
                                                 1: Fixed
                                                 2: Detect A
31 Toner Suppiy    Determines how much           o:   30%        o
    Amount         toner is supplied in          1:   15%
    (Detect        detect mode A.                2:   45%
    Mode A)                                      3:   60%
32 Toner Supply    Determines how much           o: 7%           o
    Amount         toner is supplied in          1:3.5%
    (Fixed Mode)   fixed mode.                   2: 10.5%
                                                 3: 14%
33 ID Sensor       Sets the bias voltage ap-     0:   470V       o       47oV   =   Normal
     Bias          plied to the bias roller      1:   440V               44oV   =   Lighter
                   when sensing image            2:   500V               500V   =   Darker
                   density.                      3:   530V               530V   =   Darkest
34 Toner Supply    Determines how much           o: 2%           o
    Amount         toner is supplied in          1: 4%
    (Detect        detect mode B.
    Mode B)
35 Toner Supply    Changes toner supply          o:              0       Standard: Every 10
                   interval.                      Standard               copies, 0.75V.
                   a) ID sensor checks           1:
                       every 5 copies.            increase
                   b) Toner end level
                       changes to 0.65V.
38 Edge Erase      Sets the width of mar-        0:   10mm       o
                   gin erase.                    1:   5mm
                                                 2:   15mm
                                                 3:   20mm




                                               4-9
31 January '89



                                                                    Factory
        Mode No.         Function                            Data                 Remarks
                                                                    Setting

 39 Center Erase      Sets the width of center     O:        20mm     o
                      erase.                       1:        10mm
                                                   2:        15mm
                                                   3:        25mm
 41 Lead Edge         Adjusts the lead edge        0-15              8 (3,5   1 mm per step + 10.5
    Erase Margin      margin.                                        mm)      mm to 