SC(H4SO) Starting-Charging


>> Download SC(H4SO) Starting-Charging documenatation <<

Text preview - extract from the document
STARTING/CHARGING
     SYSTEMS
                                             General Description
STARTING/CHARGING SYSTEMS

1. General Description
A: SPECIFICATION
1. NON-TURBO MODEL
                      Item                                                       Designation
            Type                                                                Reduction type
            Vehicle type                                         MT                                       AT
            Model                                            M000T30471                               M000T20171
            Manufacturer                                                       Mitsubishi Electric
            Voltage and output                              12 V -- 1.0 kW                            12 V -- 1.4 kW
            Direction of rotation                                Counterclockwise (when observed from pinion)
            Number of pinion teeth                                  8                                         9
                                Voltage                                                11 V
            No-load charac-
                                Current                       95 A or less                              90 A or less
Starter     teristics
                                Rotating speed            2,500 rpm or more                         2,000 rpm or more
                                Voltage                            8V                                       8V
            Load character- Current                               280 A                                    280 A
            istics              Torque           8.5 Nm (0.87 kgf-m, 6.3 ft-lb) or more 9.8 Nm (1.0 kgf-m, 7.2 ft-lb) or more
                                Rotating speed             970 rpm or more                          1,000 rpm or more
                                Voltage                            4V                                      3.5 V
            Lock character- Current                          680 A or less                             960 A or less
            istics                                 17 Nm (1.73 kgf-m, 12.5 ft-lb) or        31 Nm (3.16 kgf-m, 22.9 ft-lb) or
                                Torque
                                                                  more                                     more
                                                 Rotating-field three-phase, voltage regulator built-in type, with load response
            Type
                                                                                 control system
            Model                                                                 A002TG0391
            Manufacturer                                                       Mitsubishi Electric
            Voltage and output                                                     12 V -- 90 A
            Polarity on ground side                                                  Negative
Generator
            Direction of rotation                                  Clockwise (when observed from pulley side)
            Armature connection                                               Three-phase Y-type
                                                                           1,500 rpm -- 40 A or more
            Output current                                                 2,500 rpm -- 74 A or more
                                                                           5,000 rpm -- 84 A or more
            Regulated voltage                                             14.1 -- 14.8 V [20